Study of the X-ray radiation interaction with a multislit collimator for the creation of microbeams in radiation therapy

被引:15
作者
Pellicioli, P. [1 ,2 ,3 ]
Donzelli, M. [1 ,4 ]
Davis, J. A. [5 ]
Esteve, F. [2 ]
Hugtenburg, R. [3 ]
Guatelli, S. [5 ]
Petasecca, M. [5 ]
Lerch, M. L. F. [5 ]
Brauer-Krisch, E. [1 ]
Krisch, M. [1 ,2 ]
机构
[1] ESRF European Synchrotron, ID17 Biomed Beamline, 71 Ave Martyrs, Grenoble, France
[2] STROBE Synchrotron Radiat Biomed, Grenoble, France
[3] Swansea Univ, Med Sch, Singleton Pk, Swansea, W Glam, Wales
[4] ICR Inst Canc Res, London, England
[5] Univ Wollongong, Sch Phys, Wollongong, NSW, Australia
关键词
microbeam radiation therapy; multislit collimators; dosimetry; synchrotron X-ray radiation; Monte Carlo simulations; MONTE-CARLO; QUALITY-ASSURANCE; MICROPLANAR BEAM; FILM DOSIMETRY; SYNCHROTRON; SIMULATION; TRIALS; MODEL; WIDTH;
D O I
10.1107/S1600577520016811
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Microbeam radiation therapy (MRT) is a developing radiotherapy, based on the use of beams only a few tens of micrometres wide, generated by synchrotron X-ray sources. The spatial fractionation of the homogeneous beam into an array of microbeams is possible using a multislit collimator (MSC), i.e. a machined metal block with regular apertures. Dosimetry in MRT is challenging and previous works still show differences between calculated and experimental dose profiles of 10-30%, which are not acceptable for a clinical implementation of treatment. The interaction of the X-rays with the MSC may contribute to the observed discrepancies; the present study therefore investigates the dose contribution due to radiation interaction with the MSC inner walls and radiation leakage of the MSC. Dose distributions inside a water-equivalent phantom were evaluated for different field sizes and three typical spectra used for MRT studies at the European Synchrotron Biomedical beamline ID17. Film dosimetry was utilized to determine the contribution of radiation interaction with the MSC inner walls; Monte Carlo simulations were implemented to calculate the radiation leakage contribution. Both factors turned out to be relevant for the dose deposition, especially for small fields. Photons interacting with the MSC walls may bring up to 16% more dose in the valley regions, between the microbeams. Depending on the chosen spectrum, the radiation leakage close to the phantom surface can contribute up to 50% of the valley dose for a 5 mm x 5 mm field. The current study underlines that a detailed characterization of the MSC must be performed systematically and accurate MRT dosimetry protocols must include the contribution of radiation leakage and radiation interaction with the MSC in order to avoid significant errors in the dose evaluation at the micrometric scale.
引用
收藏
页码:392 / 403
页数:12
相关论文
共 53 条
[1]   GEANT4-a simulation toolkit [J].
Agostinelli, S ;
Allison, J ;
Amako, K ;
Apostolakis, J ;
Araujo, H ;
Arce, P ;
Asai, M ;
Axen, D ;
Banerjee, S ;
Barrand, G ;
Behner, F ;
Bellagamba, L ;
Boudreau, J ;
Broglia, L ;
Brunengo, A ;
Burkhardt, H ;
Chauvie, S ;
Chuma, J ;
Chytracek, R ;
Cooperman, G ;
Cosmo, G ;
Degtyarenko, P ;
Dell'Acqua, A ;
Depaola, G ;
Dietrich, D ;
Enami, R ;
Feliciello, A ;
Ferguson, C ;
Fesefeldt, H ;
Folger, G ;
Foppiano, F ;
Forti, A ;
Garelli, S ;
Giani, S ;
Giannitrapani, R ;
Gibin, D ;
Cadenas, JJG ;
González, I ;
Abril, GG ;
Greeniaus, G ;
Greiner, W ;
Grichine, V ;
Grossheim, A ;
Guatelli, S ;
Gumplinger, P ;
Hamatsu, R ;
Hashimoto, K ;
Hasui, H ;
Heikkinen, A ;
Howard, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) :250-303
[2]  
[Anonymous], 2009, PENELOPE 2008 CODE S
[3]   Microbeam radiosurgery using synchrotron-generated submillimetric beams: a new tool for the treatment of brain disorders [J].
Anschel, David J. ;
Bravin, Alberto ;
Romanelli, Pantaleo .
NEUROSURGICAL REVIEW, 2011, 34 (02) :133-141
[4]  
Archer D. W., 1998, U.S. patent, Patent No. [5,771,270, 5771270]
[5]   Technical advances in x-ray microbeam radiation therapy [J].
Bartzsch, Stefan ;
Corde, Stephanie ;
Crosbie, Jeffrey C. ;
Day, Liam ;
Donzelli, Mattia ;
Krisch, Michael ;
Lerch, Michael ;
Pellicioli, Paolo ;
Smyth, Lloyd M. L. ;
Tehei, Moeava .
PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (02)
[6]   A preclinical microbeam facility with a conventional x-ray tube [J].
Bartzsch, Stefan ;
Cummings, Craig ;
Eismann, Stephan ;
Oelfke, Uwe .
MEDICAL PHYSICS, 2016, 43 (12) :6301-6308
[7]   Influence of polarization and a source model for dose calculation in MRT [J].
Bartzsch, Stefan ;
Lerch, Michael ;
Petasecca, Marco ;
Braeuer-Krisch, Elke ;
Oelfke, Uwe .
MEDICAL PHYSICS, 2014, 41 (04)
[8]   Synchrotron microbeam radiation therapy induces hypoxia in intracerebral gliosarcoma but not in the normal brain [J].
Bouchet, Audrey ;
Lemasson, Benjamin ;
Christen, Thomas ;
Potez, Marine ;
Rome, Claire ;
Coquery, Nicolas ;
Le Clec'h, Celine ;
Moisan, Anaick ;
Braeuer-Krisch, Elke ;
Leduc, Geraldine ;
Remy, Chantal ;
Laissue, Jean A. ;
Barbier, Emmanuel L. ;
Brun, Emmanuel ;
Serduc, Raphael .
RADIOTHERAPY AND ONCOLOGY, 2013, 108 (01) :143-148
[9]   PREFERENTIAL EFFECT OF SYNCHROTRON MICROBEAM RADIATION THERAPY ON INTRACEREBRAL 9L GLIOSARCOMA VASCULAR NETWORKS [J].
Bouchet, Audrey ;
Lemasson, Benjamin ;
Le Duc, Geraldine ;
Maisin, Cecile ;
Brauer-Krisch, Elke ;
Siegbahn, Erik Albert ;
Renaud, Luc ;
Khalil, Enam ;
Remy, Chantal ;
Poillot, Cathy ;
Bravin, Alberto ;
Laissue, Jean A. ;
Barbier, Emmanuel L. ;
Serduc, Raphael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (05) :1503-1512
[10]   Effects of pulsed, spatially fractionated, microscopic synchrotron X-ray beams on normal and tumoral brain tissue [J].
Braeuer-Krisch, E. ;
Serduc, R. ;
Siegbahn, E. A. ;
Le Duc, G. ;
Prezado, Y. ;
Bravin, A. ;
Blattmann, H. ;
Laissue, J. A. .
MUTATION RESEARCH-REVIEWS IN MUTATION RESEARCH, 2010, 704 (1-3) :160-166