Stator-flux-based vector control of induction machines in magnetic saturation

被引:29
作者
Hofmann, H [1 ]
Sanders, SR [1 ]
Sullivan, CR [1 ]
机构
[1] DARTMOUTH COLL, THAYER SCH ENGN, HANOVER, NH 03755 USA
基金
美国国家科学基金会;
关键词
induction machines; magnetic saturation; torque control;
D O I
10.1109/28.605735
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In many variable-torque applications of induction machines, it is desirable to operate the machine at high Aux levels, thus allowing the machine to produce higher torques. This can lead to saturation of the main flux path, introducing cross-coupling effects which can severely disrupt the performance of controllers dependent on knowledge of the machine's magnetic parameters. Stator-flux-oriented torque-control schemes need not depend on the magnetic parameters of the machine and, hence, are potentially more robust and easier to implement in magnetic saturation than rotor-flux-oriented control. In this paper, we present and analyze a stator-flux-oriented torque-control scheme. This controller only requires knowledge of the stator voltage, stator current, and stator resistance. An analytical expression for the maximum achievable torque output of the machine using a linear magnetics model is compared with values calculated using a nonlinear magnetics model incorporating saturation of the main flux path and is shown to be a good approximation at high flux levels, when the main flux path is heavily saturated. Experiments carried out on a 3-hp 1800-r/min wound-rotor induction machine show smooth operation of the control scheme at torque levels up to at least four times rated torque.
引用
收藏
页码:935 / 942
页数:8
相关论文
共 29 条
[1]   A METHOD OF INCLUDING THE EFFECTS OF MAIN FLUX PATH SATURATION IN THE GENERALIZED EQUATIONS OF AC MACHINES [J].
BROWN, JE ;
KOVACS, KP ;
VAS, P .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1983, 102 (01) :96-103
[2]  
COLBY RS, 1990, 21 ANN IEEE POW EL S, P678
[3]   INDUCTION MACHINE FIELD ORIENTATION ALONG AIRGAP AND STATOR FLUX [J].
ERDMAN, WL ;
HOFT, RG .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 1990, 5 (01) :115-121
[4]  
FRANCIS CJ, 1994, IEE CONF PUBL, P54
[5]  
GARRIDO MS, 1988, MODELLING SIMULATION, P137
[6]  
Gastli A., 1994, Transactions of the Institute of Electrical Engineers of Japan, Part D, V114-D, P9, DOI 10.1541/ieejias.114.9
[7]  
HABETLER TG, 1993, P 5 EUR C POW EL APP, V4, P292
[9]   SELECTION OF FLUX LEVEL IN FIELD-ORIENTED INDUCTION MACHINE CONTROLLERS WITH CONSIDERATION OF MAGNETIC SATURATION EFFECTS [J].
KHATER, FMH ;
LORENZ, RD ;
NOVOTNY, DW ;
TANG, K .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1987, 23 (02) :276-282
[10]  
KLIMAN GB, 1996, 31 IEEE IAS ANN M, P633