Time-resolved beam symmetry measurement for VMAT commissioning and quality assurance

被引:1
作者
Barnes, Michael P. [1 ,2 ]
Greer, Peter B. [1 ,3 ]
机构
[1] Calvary Mater Hosp, Dept Radiat Oncol, Newcastle, NSW, Australia
[2] Univ Newcastle, Sch Med Radiat Sci, Newcastle, NSW 2300, Australia
[3] Univ Newcastle, Sch Math & Phys Sci, Newcastle, NSW 2300, Australia
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2016年 / 17卷 / 02期
关键词
symmetry; VMAT; commissioning; quality assurance; VOLUMETRIC MODULATED ARC; DOSIMETRY; THERAPY;
D O I
10.1120/jacmp.v17i2.6026
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In volumetric-modulated arc therapy (VMAT) treatment delivery perfect beam symmetry is assumed by the planning system. This study aims to test this assumption and present a method of measuring time-resolved beam symmetry measurement during a VMAT delivery that includes extreme variations of dose rate and gantry speed. The Sun Nuclear IC Profiler in gantry mount was used to measure time-resolved in-plane and cross-plane profiles during plan delivery from which symmetry could be determined. Time-resolved symmetry measurements were performed throughout static field exposures at cardinal gantry angles, conformal arcs with constant dose rate and gantry speed, and during a VMAT test plan with gantry speed and dose rate modulation. Measurements were performed for both clockwise and counterclockwise gantry rotation and across four Varian 21iX linacs. The symmetry was found to be generally constant throughout the static field exposures to within 0.3% with an exception on one linac of up to 0.7%. Agreement in symmetry between cardinal angles was always within 1.0% and typically within 0.6%. During conformal arcs the results for clockwise and counterclockwise rotation were in agreement to within 0.3%. Both clockwise and counterclockwise tended to vary in similar manner by up to 0.5% during arc consistent with the cardinal gantry angle static field results. During the VMAT test plan the symmetry generally was in agreement with the conformal arc results. Greater variation in symmetry was observed in the low-dose-rate regions by up to 1.75%. All results were within clinically acceptable levels using the tolerances of NCS Report 24 (2015).
引用
收藏
页码:220 / 230
页数:11
相关论文
共 19 条
  • [1] Commissioning and quality assurance for VMAT delivery systems: An efficient time-resolved system using real-time EPID imaging
    Zwan, Benjamin J.
    Barnes, Michael P.
    Hindmarsh, Jonathan
    Lim, Seng B.
    Lovelock, Dale M.
    Fuangrod, Todsaporn
    O'Connor, Daryl J.
    Keall, Paul J.
    Greer, Peter B.
    MEDICAL PHYSICS, 2017, 44 (08) : 3909 - 3922
  • [2] A novel and independent method for time-resolved gantry angle quality assurance for VMAT
    Fuangrod, Todsaporn
    Greer, Peter B.
    Zwan, Benjamin J.
    Barnes, Michael P.
    Lehmann, Joerg
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2017, 18 (05): : 134 - 142
  • [3] VMAT linear accelerator commissioning and quality assurance: dose control and gantry speed tests
    Barnes, Michael P.
    Rowshanfarzad, Pejman
    Greer, Peter B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (03): : 246 - 261
  • [4] Time-resolved dosimetry using a pinpoint ionization chamber as quality assurance for IMRT and VMAT
    Louwe, Robert J. W.
    Wendling, Markus
    Monshouwer, Rene
    Satherley, Thomas
    Day, Rebecca A.
    Greig, Lynne
    MEDICAL PHYSICS, 2015, 42 (04) : 1625 - 1639
  • [5] Report on Use of a Methodology for Commissioning and Quality Assurance of a VMAT System
    Mayo, Charles
    de los Santos, Luis Fong
    Kruse, Jon
    Blackwell, Charles R.
    McLemore, Luke B.
    Pafundi, Deanna
    Stoker, Joshua
    Herman, Michael
    PLOS ONE, 2013, 8 (03):
  • [6] Quantified VMAT plan complexity in relation to measurement-based quality assurance results
    Nguyen, Michael
    Chan, Gordon H.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (11): : 132 - 140
  • [7] An EPID-based system for gantry-resolved MLC quality assurance for VMAT
    Zwan, Benjamin J.
    Barnes, Michael P.
    Fuangrod, Todsaporn
    Stanton, Cameron J.
    O'Connor, Daryl J.
    Keall, Paul J.
    Greer, Peter B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (05): : 348 - 365
  • [8] Simplified sigmoidal curve fitting for a 6 MV FFF photon beam of the Halcyon to determine the field size for beam commissioning and quality assurance
    Choi, Min-Geon
    Law, Martin
    Yoon, Do-Kun
    Tamura, Mikoto
    Matsumoto, Kenji
    Otsuka, Masakazu
    Kim, Moo-Sub
    Djeng, Shih-Kien
    Monzen, Hajime
    Suh, Tae Suk
    RADIATION ONCOLOGY, 2020, 15 (01)
  • [9] Sensitivity and specificity of time resolved point dose measurements for patient specific quality assurance
    Scarlet, Benjamin Ew
    Williams, Andrew J.
    Marsh, Steven
    Louwe, Robert J. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (14)
  • [10] Faraday cup for commissioning and quality assurance for proton pencil beam scanning beams at conventional and ultra-high dose rates
    Winterhalter, C.
    Togno, M.
    Nesteruk, K. P.
    Emert, F.
    Psoroulas, S.
    Vidal, M.
    Meer, D.
    Weber, D. C.
    Lomax, A.
    Safai, S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (12)