Handheld real-time volumetric 3-D gamma-ray imaging

被引:44
|
作者
Haefner, Andrew [1 ]
Barnowski, Ross [2 ]
Luke, Paul [1 ]
Amman, Mark [1 ]
Vetter, Kai [1 ,2 ]
机构
[1] Lawrence Berkeley Natl Lab, Appl Nucl Phys, 1 Cyclotron Rd, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Dept Nucl Engn, 4155 Etcheverry Hall,MC 1730, Berkeley, CA 94720 USA
关键词
Compton imaging; Gamma-ray imaging; SLAM; 3-D imaging; Volumetric imaging; Data fusion; EFFICIENCY MULTIMODE IMAGER; COMPTON CAMERA; EM ALGORITHM;
D O I
10.1016/j.nima.2016.11.046
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper presents the concept of real-time fusion of gamma-ray imaging and visual scene data for a hand-held mobile Compton imaging system in 3-D. The ability to obtain and integrate both gamma-ray and scene data from a mobile platform enables improved capabilities in the localization and mapping of radioactive materials. This not only enhances the ability to localize these materials, but it also provides important contextual information of the scene which once acquired can be reviewed and further analyzed subsequently. To demonstrate these concepts, the high-efficiency multimode imager (HEMI) is used in a hand-portable implementation in combination with a Microsoft Kinect sensor. This sensor, in conjunction with open-source software, provides the ability to create a 3-D model of the scene and to track the position and orientation of HEMI in real-time. By combining the gamma-ray data and visual data, accurate 3-D maps of gamma-ray sources are produced in real-time. This approach is extended to map the location of radioactive materials within objects with unknown geometry.
引用
收藏
页码:42 / 49
页数:8
相关论文
共 50 条
  • [41] 3D motion-compensated optical coherence tomography based on higher-order regression towards real-time volumetric imaging of the cornea
    Zuo, Ruizhi
    Wang, Yaning
    Irsch, Kristina
    Kang, Jin U.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XXVI, 2022, 11948
  • [42] Rapidly-steered single-element ultrasound for real-time volumetric imaging and guidance
    Stauber, Mark
    Western, Craig
    Solek, Roman
    Salisbury, Ken
    Hristov, Dimitre
    Schlosser, Jeffrey
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [43] Liquid Xenon for Gamma-Ray Imaging of Special Nuclear Materials
    Larsen, Nicole A.
    Bernard, Ethan P.
    Cahn, Sidney B.
    Edwards, Blair
    Linck, Evan
    Lyashenko, Alexey
    McKinsey, Daniel N.
    Nikkel, James A.
    Rhyne, Casey A.
    Shin, Yunchang
    Tennyson, Brian P.
    Wahl, Christopher G.
    Destefano, Nicholas E.
    Gai, Moshe
    De Silva, Manawaduge S.
    2012 IEEE INTERNATIONAL CONFERENCE ON TECHNOLOGIES FOR HOMELAND SECURITY, 2012, : 378 - 383
  • [44] Gamma-ray imaging detectors based on SDDs coupled to scintillators
    Fiorini, C
    Longoni, A
    Perotti, F
    Labanti, C
    Rossi, E
    Lechner, P
    Strüder, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3) : 565 - 567
  • [45] Building a pixellated detector for gamma-ray imaging: the PICsIT example
    Labanti, C
    Di Cocco, G
    Ferro, G
    Bottacini, E
    Gianotti, F
    Mauri, A
    Rossi, E
    Stephen, JB
    Traci, A
    Trifoglio, M
    Valli, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 213 : 260 - 266
  • [46] Gamma-ray imaging performance of the GRI plus Compton camera
    Caffrey, A.
    Harkness-Brennan, L. J.
    Alshammari, H.
    Boston, A. J.
    Boston, H. C.
    Griffiths, O.
    Judson, D. S.
    Kalantan, S.
    Le Crom, B.
    Nolan, P. J.
    Powell, A.
    Platt, J.
    Randall, G.
    Reid, C.
    Rintoul, E.
    Unsworth, C.
    Woodroof, T. F.
    Burrows, I.
    Lazarus, I. H.
    Simpson, J.
    Atkinson, K. D.
    JOURNAL OF INSTRUMENTATION, 2021, 16 (09)
  • [47] A Spherical Active Coded Aperture for 4π Gamma-Ray Imaging
    Hellfeld, Daniel
    Barton, Paul
    Gunter, Donald
    Mihailescu, Lucian
    Vetter, Kai
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2017, 64 (11) : 2837 - 2842
  • [48] Gamma-ray energy-imaging integrated spectral deconvolution
    Xu, D.
    He, Z.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 574 (01) : 98 - 109
  • [49] Experimental Results of the Gamma-Ray Imaging Capability With a Si/CdTe Semiconductor Compton Camera
    Takeda, Shin'ichiro
    Aono, Hiroyuki
    Okuyama, Sho
    Ishikawa, Shin-nosuke
    Odaka, Hirokazu
    Watanabe, Shin
    Kokubun, Motohide
    Takahashi, Tadayuki
    Nakazawa, Kazuhiro
    TajimaHiro, Hiroyasu
    Kawachi, Naoki
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (03) : 783 - 790
  • [50] A germanium orthogonal strip detector system for gamma-ray imaging
    Hull, EL
    Burks, MT
    Cork, CP
    Craig, W
    Eckels, D
    Fabris, L
    Lavietes, A
    Luke, PN
    Madden, NW
    Pehl, RH
    Ziock, KP
    HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS III, 2001, 4507 : 132 - 140