Sensitive amperometric immunosensing using polypyrrolepropylic acid films for biomolecule immobilization

被引:76
作者
Dong, Hua
Li, Chang Ming
Chen, Wei
Zhou, Qin
Zeng, Zhao Xian
Luong, John H. T.
机构
[1] Nanyang Technol Univ, Sch Chem & Biomed Engn, Singapore 639798, Singapore
[2] Watson Pharma Inc, Phoenix, AZ 85043 USA
[3] Natl Res Council Canada, Biotechnol Res Inst, Montreal, PQ H4P 2R2, Canada
关键词
D O I
10.1021/ac060657o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An electrochemical immunosensor was constructed using an electropolymerized pyrrolepropylic acid (PPA) film with high porosity and hydrophilicity. A high density of carboxyl groups of PPA was used to covalently attach protein probes, leading to significantly improved detection sensitivity compared with conventional entrapment methods. As a model, anti-mouse IgG was covalently immobilized or entrapped in the PPA film and used in a sandwich-type alkaline phosphatase-catalyzing amperometric immunoassay with p-aminophenyl phosphate as the substrate. With covalent binding, the detection limit for IgG in PBS buffer, pH 7.4, was 100 pg/mL with a dynamic range of 5 orders of magnitude. The covalent bonding mode in the carbonate-bicarbonate buffer, pH 9.6, further brought down the detection limit to 20 pg/mL with remarkable selectivity.
引用
收藏
页码:7424 / 7431
页数:8
相关论文
共 31 条
[1]   Self-contained microelectrochemical immunoassay for small volumes using mouse IgG as a model system [J].
Aguilar, ZP ;
Vandaveer, WR ;
Fritsch, I .
ANALYTICAL CHEMISTRY, 2002, 74 (14) :3321-3329
[2]   Microfluidic immunosensor systems [J].
Bange, A ;
Halsall, HB ;
Heineman, WR .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2488-2503
[3]   Zeptomole-detecting biosensor for alkaline phosphatase in an electrochemical immunoassay for 2,4-dichlorophenoxyacetic acid [J].
Bauer, CG ;
Eremenko, AV ;
EhrentreichForster, E ;
Bier, FF ;
Makower, A ;
Halsall, HB ;
Heineman, WR ;
Scheller, FW .
ANALYTICAL CHEMISTRY, 1996, 68 (15) :2453-2458
[4]   ELECTROCHEMISTRY OF THE POLYPYRROLE GLUCOSE-OXIDASE ELECTRODE [J].
BELANGER, D ;
NADREAU, J ;
FORTIER, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1989, 274 (1-2) :143-155
[5]   An integrated microfluidic biochemical detection system for protein analysis with magnetic bead-based sampling capabilities [J].
Choi, JW ;
Oh, KW ;
Thomas, JH ;
Heineman, WR ;
Halsall, HB ;
Nevin, JH ;
Helmicki, AJ ;
Henderson, HT ;
Ahn, CH .
LAB ON A CHIP, 2002, 2 (01) :27-30
[6]   Biomolecule immobilization on electrode surfaces by entrapment or attachment to electrochemically polymerized films. A review [J].
Cosnier, S .
BIOSENSORS & BIOELECTRONICS, 1999, 14 (05) :443-456
[7]   Glucose biosensor based on multi-walled carbon nanotube modified glassy carbon electrode [J].
Dai, YQ ;
Shiu, KK .
ELECTROANALYSIS, 2004, 16 (20) :1697-1703
[8]   Potential-induced enantioselective uptake of amino acid into molecularly imprinted overoxidized polypyrrole [J].
Deore, B ;
Chen, ZD ;
Nagaoka, T .
ANALYTICAL CHEMISTRY, 2000, 72 (17) :3989-3994
[9]   Feasibility studies of simultaneous multianalyte amperometric immunoassay based on spatial resolution [J].
Ding, Y ;
Zhou, LP ;
Halsall, HB ;
Heineman, WR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1999, 19 (1-2) :153-161
[10]  
DONG H, IN PRESS BIOSENS BIO