The influence of the shock-absorbing restorative materials on the stress distributions of short dental implant rehabilitations

被引:6
作者
Huang, Z-L
Shi, J-Y
Zhang, X.
Gu, Y-X [1 ]
Lai, H-C [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Med, Coll Stomatol, Dept Implantol,Shanghai Peoples Hosp 9, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
Dental implant; Stress distribution; Shock-absorption ability; Polyetheretherketone; Polymer-infiltrated ceramic-network; CROWN; AREAS; PEEK; BONE;
D O I
10.26355/eurrev_202101_24341
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
OBJECTIVE: Polymer materials with shock-absorbing ability may offer better stress distribution with short dental implants (SDI). The present study aimed to evaluate the effect of abutment and crown materials on the stress distributions in short implant-prosthesis-complex (6 mm) and standard implant-prosthesis-complex (10 mm) using 3D finite element analysis (FEA). MATERIALS AND METHODS: Two FEA models were designed to simulated single implant restoration of mandibular first molar, one each for short implant (6 mm) (Group S) and standard implant (10 mm) (Group C). In each group. two abutment materials were used. Polyetheretherketone (PEEK) and Zirconia (Zr), with two types of crowns, PEEK and Polymer-infiltrated ceramic-network (PICN). A vertical force of 200 N was applied to each central fossa. Stress distribution was evaluated via the von Mises stress analysis. RESULTS: Using the PEEK abutment, the stress was better dispersed with PEEK crowns, as compared to PICN crowns. The stress was concentrated on the platforms of Ti-bases and the head and middle part of abutment screws. In zirconia abutment, the stress was greatly concentrated on the axial angle regions when placed with the PEEK crowns. while the stress was dispersed when placed with PICN crowns. The stress was concentrated on the connector regions of Ti-bases and the middle part of abutment screws. For implants, the stress was concentrated on the neck of the two implants, regardless of crown materials and abutment materials. The PEEK materials were found to be suitable for the hybrid-retained prostheses of SDI. CONCLUSIONS: Our study indicates that the PEEK material is more suitable for the hybrid restorations of SDI. If the Zr abutment is used, the PICN crown would be better. Further, in-vivo clinical trials comparing these materials are needed to strengthen evidence.
引用
收藏
页码:24 / 34
页数:11
相关论文
共 24 条
  • [1] Long-term retrospective evaluation of short implants in the posterior areas: clinical results after 10-12 years
    Anitua, Eduardo
    Pinas, Laura
    Begona, Leire
    Orive, Gorka
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 2014, 41 (04) : 404 - 411
  • [2] Influences of Implant and Framework Materials on Stress Distribution: A Three-Dimensional Finite Element Analysis Study
    Bahadirli, Gulcan
    Yilmaz, Suat
    Jones, Tobie
    Sen, Deniz
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (05) : E117 - E126
  • [3] Biomechanical properties of polymer-infiltrated ceramic crowns on one-piece zirconia implants after long-term chewing simulation
    Baumgart, Pia
    Kirsten, Holger
    Haak, Rainer
    Olms, Constanze
    [J]. INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [4] Stress dissipation in the bone through various crown materials of dental implant restoration: a 2-D finite element analysis
    Bijjargi, Supriya
    Chowdhary, Ramesh
    [J]. JOURNAL OF INVESTIGATIVE AND CLINICAL DENTISTRY, 2013, 4 (03) : 172 - 177
  • [5] Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features
    Cho, Sung-Yong
    Huh, Yun-Hyuk
    Park, Chan-Jin
    Cho, Lee-Ra
    [J]. INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (02) : 319 - 327
  • [6] Influence of Different CAD/CAM Crown Materials on the Fracture of Custom-Made Titanium and Zirconia Implant Abutments After Artificial Aging
    Elsayed, Adham
    Farrag, Gasser
    Chaar, Mohamed Sad
    Abdelnabi, Nouran
    Kern, Matthias
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2019, 32 (01) : 91 - 96
  • [7] Effect of different restorative crown and customized abutment materials on stress distribution in single implants and peripheral bone: A three-dimensional finite element analysis study
    Kaleli, Necati
    Sarac, Duygu
    Kulunk, Safak
    Ozturk, Ozgur
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2018, 119 (03) : 437 - 445
  • [8] Kao HC, 2008, INT J ORAL MAX IMPL, V23, P623
  • [9] Damping behavior of implant-supported restorations
    Magne, Pascal
    Silva, Michael
    Oderich, Elisa
    Boff, Luis Leonildo
    Enciso, Reyes
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (02) : 143 - 148
  • [10] Is there an effect of crown-to-implant ratio on implant treatment outcomes? A systematic review
    Meijer, Henny J. A.
    Boven, Carina
    Delli, Konstantina
    Raghoebar, Gerry M.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 : 243 - 252