A novel, label-free immunosensor for the detection of α-fetoprotein using functionalised gold nanoparticles

被引:42
|
作者
Liang, Wenbin [1 ,2 ]
Yi, Weijing [2 ]
Li, Shuhui [2 ]
Yuan, Ruo [1 ]
Chen, An [2 ]
Chen, Sha [2 ]
Xiang, Guiming [3 ]
Hu, Chuanmin [2 ]
机构
[1] Southwest Univ, Coll Chem & Chem Engn, Chongqing Key Lab Analyt Chem, Chongqing 400715, Peoples R China
[2] Third Mil Med Univ, Lab Sci, Dept Clin Biochem, Chongqing 400038, Peoples R China
[3] Third Mil Med Univ, Xinqiao Hosp, Dept Lab Med, Chongqing 40037, Peoples R China
基金
中国国家自然科学基金;
关键词
Sulfhyrdryl viologen; Functional gold nanoparticle; alpha-1-fetoprotein; Immunosensor; DISPOSABLE AMPEROMETRIC IMMUNOSENSOR; ANTIGEN-ANTIBODY INTERACTIONS; SEPARATION-FREE IMMUNOASSAY; HEPATOCELLULAR-CARCINOMA; IMPEDANCE SPECTROSCOPY; ELECTRODE; FILMS; ALPHA-1-FETOPROTEIN; THIONINE; SERUM;
D O I
10.1016/j.clinbiochem.2009.07.009
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background and objectives: Novel immunoassay methods based on electrochemical sensors have been developed, but most of these immunosensors are unsuitable for clinical detection because their preparation requires complicated chemical procedures and because their detection sensitivity is restricted. In order to develop a highly sensitive, label-free amperometric sensor for immunoassays, we synthesised novel, functionalised gold nanoparticles (SV-GNP) by covalently capping the surface of gold nanoparticles (GNP) with 1,1'-bis-(2-mercapto)-4,4'-bipyridinium dibromide, a kind of sulfhyrdryl viologen (SV). Design and methods: We fabricated an immunosensor in a multi-step fashion, by first coating the SV-GNP onto a glassy carbon electrode surface; the resulting electrode core could then adsorb a suitable antibody in a second step to afford the desired immunosensor. alpha-fetoprotein (AFP) was used as a model analyte in this work. Results: The anti-AFP/SV-GNP-modified electrode was sensitive to AFP with a linear relationship between 1.25 and 200 ng/mL and a correlation coefficient of 0.9983; the detection limit at a signal to noise ratio of 3 was 0.23 ng/mL under optimal conditions. In addition, the proposed immunosensor exhibited good sensitivity, selectivity, stability and long-term maintenance of bioactivity. Conclusion: The described immunosensor preparation and immunoassay methods offer promise for label-free, simple, and cost-effective analysis of biological samples. (C) 2009 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1524 / 1530
页数:7
相关论文
共 50 条
  • [1] A novel label-free voltammetric immunosensor for the detection of α-fetoprotein using functional titanium dioxide nanoparticles
    Liang, Wen-Bin
    Yuan, Ruo
    Chai, Ya-Qin
    Li, Yan
    Zhuo, Ying
    ELECTROCHIMICA ACTA, 2008, 53 (05) : 2302 - 2308
  • [2] A label-free electrochemical immunosensor based on gold nanoparticles for detection of paraoxon
    Hu, SQ
    Xie, JW
    Xu, QH
    Rong, KT
    Shen, GL
    Yu, RQ
    TALANTA, 2003, 61 (06) : 769 - 777
  • [3] Label-free detection of bisphenol A using a potentiometric immunosensor
    Piao, Ming-Hua
    Noh, Hui-Bog
    Rahman, Md Aminur
    Won, Mi-Sook
    Shim, Yoon-Bo
    ELECTROANALYSIS, 2008, 20 (01) : 30 - 37
  • [4] A Label-Free Immunosensor Based on Gold Nanoparticles/Thionine for Sensitive Detection of PAT Protein in Genetically Modified Crops
    Yang, Qianwen
    Wang, Yu
    Liu, Xiaofeng
    Liu, Hua
    Bao, Huifang
    Wang, Jinbin
    Zeng, Haijuan
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [5] A novel label-free immunosensor for detection of VEGF using FFT admittance voltammetry
    Heidari, Negar
    Sajedi, Reza Hassan
    Kharat, Ali Nemati
    Bonakdar, Alireza
    Mirzazadeh, Jalil
    Qaraei, Kianoush Kazemi
    Norouzi, Parviz
    BIOELECTROCHEMISTRY, 2025, 165
  • [6] Label-free impedimetric immunosensor for sensitive detection of ochratoxin A
    Radi, Abd-Elgawad
    Munoz-Berbel, Xavier
    Lates, Vasilica
    Marty, Jean-Louis
    BIOSENSORS & BIOELECTRONICS, 2009, 24 (07) : 1888 - 1892
  • [7] A novel label-free impedimetric immunosensor for detection of semicarbazide residue based on gold nanoparticles-functional chitosan composite membrane
    Jin, Wen-Jie
    Yang, Gong-Jun
    Shao, Hong-Xia
    Qin, Ai-Jian
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 271 - 279
  • [8] Nanoporous gold film based immunosensor for label-free detection of cancer biomarker
    Wei, Qin
    Zhao, Yanfang
    Xu, Caixia
    Wu, Dan
    Cai, Yanyan
    He, Jing
    Li, He
    Du, Bin
    Yang, Minghui
    BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) : 3714 - 3718
  • [9] An impedimetric immunosensor for the label-free detection of bisphenol A
    Rahman, Md. Aminur
    Shiddiky, Muhammad J. A.
    Park, Jang-Su
    Shim, Yoon-Bo
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (11) : 2464 - 2470
  • [10] Label-free disposable immunosensor for detection of atrazine
    Belkhamssa, Najet
    Justino, Celine I. L.
    Santos, Patricia S. M.
    Cardoso, Susana
    Lopes, Isabel
    Duarte, Armando C.
    Rocha-Santos, Teresa
    Ksibi, Mohamed
    TALANTA, 2016, 146 : 430 - 434