Accuracy analysis and improvement of the state-queuing model for the thermostatically controlled loads

被引:17
作者
Bao, Yu-Qing [1 ,2 ]
Hu, Minqiang [1 ,2 ]
Hong, Ying-Yi [3 ]
Chen, Pei-Pei [1 ]
Ju, Jia-Qi [1 ]
Ma, Gang [1 ]
机构
[1] Nanjing Normal Univ, Sch Elect & Automat Engn, Nanjing, Jiangsu, Peoples R China
[2] Nanjing Normal Univ, Postdoctoral Res Ctr Phys, Nanjing, Jiangsu, Peoples R China
[3] Chung Yuan Christian Univ, Dept Elect Engn, Chungli, Taiwan
关键词
smart meters; demand side management; load regulation; optimisation; thermostatically controlled loads; computationally efficient state-queuing model; smart metering technology; demand response programs; direct load control; optimisation technique; DEMAND;
D O I
10.1049/iet-gtd.2016.1427
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The development of smart metering technologies makes it possible to apply the thermostatically controlled loads (TCLs) into the demand response programs such as direct load control. To characterise the dynamics of a large number of TCLs, the computationally efficient sate-queuing (SQ) model is designed in some recent research works. However, very few attentions have been given to its accuracy. This study reviews the existing SQ modelling approach, and reveals its limitations in the accuracy by comprehensive comparison and analysis. To improve the accuracy of the SQ model, a modification method is specially designed based on the optimisation technique. Numerous simulation results verify the effectiveness of the proposed method.
引用
收藏
页码:1303 / 1310
页数:8
相关论文
共 19 条
[1]  
[Anonymous], 2009, P 6 VIENN INT C MATH
[2]   Design of a hybrid hierarchical demand response control scheme for the frequency control [J].
Bao, Yu-Qing ;
Li, Yang ;
Hong, Ying-Yi ;
Wang, Beibei .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2015, 9 (15) :2303-2310
[3]   MARKOV PROPERTIES OF A MARKOV PROCESS [J].
GETOOR, RK ;
SHARPE, MJ .
ZEITSCHRIFT FUR WAHRSCHEINLICHKEITSTHEORIE UND VERWANDTE GEBIETE, 1981, 55 (03) :313-330
[4]  
Holland JH., 1992, ADAPTATION NATURAL A, DOI [10.7551/mitpress/1090.001.0001, DOI 10.7551/MITPRESS/1090.001.0001]
[5]   A Closed-Loop Control Strategy for Air Conditioning Loads to Participate in Demand Response [J].
Hu, Xiaoqing ;
Wang, Beibei ;
Yang, Shengchun ;
Short, Taylor ;
Zhou, Lei .
ENERGIES, 2015, 8 (08) :8650-8681
[6]  
Koch S, 2011, P 17 POW SYST COMP C
[7]   A state-queueing model of thermostatically controlled appliances [J].
Lu, N ;
Chassin, DP .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (03) :1666-1673
[8]  
Lu N, 2005, IEEE POWER ENG SOC, P1336
[9]   Design Considerations of a Centralized Load Controller Using Thermostatically Controlled Appliances for Continuous Regulation Reserves [J].
Lu, Ning ;
Zhang, Yu .
IEEE TRANSACTIONS ON SMART GRID, 2013, 4 (02) :914-921
[10]   An Evaluation of the HVAC Load Potential for Providing Load Balancing Service [J].
Lu, Ning .
IEEE TRANSACTIONS ON SMART GRID, 2012, 3 (03) :1263-1270