Monitoring capabilities of cardiac rhythm management devices

被引:5
作者
Andrikopoulos, George [2 ]
Tzeis, Stylianos [3 ]
Theodorakis, George [2 ]
Vardas, Panos [1 ]
机构
[1] Heraklion Univ Hosp, Dept Cardiol, Iraklion 71110, Crete, Greece
[2] Henry Dunant Hosp, Dept Cardiol, Athens, Greece
[3] Tech Univ Munich, Fac Med, Deutsch Herzzentrum & Med Klin, Munich, Germany
来源
EUROPACE | 2010年 / 12卷 / 01期
关键词
Implantable devices; Monitoring; Algorithms; CHRONIC HEART-FAILURE; CARDIOVERTER-DEFIBRILLATOR PATIENTS; REDUCE INAPPROPRIATE SHOCKS; DUAL-CHAMBER PACEMAKERS; HIGH-RATE EPISODES; ATRIAL-FIBRILLATION; RATE-VARIABILITY; FOLLOW-UP; LEAD FAILURE; ELECTROMAGNETIC-INTERFERENCE;
D O I
10.1093/europace/eup317
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Since the advent of the first generation pacemakers, solely providing rate support, we have witnessed a technological outburst in the type and complexity of implantable devices. The introduction of implantable cardioverter defibrillators and later of cardiac resynchronization therapy devices enriched our therapeutic arsenal for the management of patients with heart failure and/or high risk of sudden cardiac death. In addition, during the last decade, newer generation cardiac rhythm management devices (CRMs) have been capable to provide a continuously expanding pool of diagnostic information derived by novel monitoring capabilities. Although at present the clinical role of this information is undervalued, it is evident that the clinical exploitation of data derived by CRMs may transform the standards of care for our patients by providing timely applied individualized diagnosis and treatment. In this context, even in the absence of solid data supporting the use of this information in everyday clinical practice, improving our familiarity with currently available monitoring algorithms is a perquisite for the electrophysiologist who keeps in pace with the rapidly evolving technologies of CRMs and is prepared for their future role on clinical practice.
引用
收藏
页码:17 / 23
页数:7
相关论文
共 90 条
[71]   Automatic measurement of atrial pacing thresholds in dual-chamber pacemakers: Clinical experience with atrial capture management [J].
Sperzel, J ;
Milasinovic, G ;
Smith, TW ;
Mead, H ;
Brandt, J ;
Haisty, WK ;
Bailey, JR ;
Roelke, M ;
Simonson, J ;
Englund, J ;
Farges, E ;
Compton, S .
HEART RHYTHM, 2005, 2 (11) :1203-1210
[72]   What is the real atrial fibrillation burden after catheter ablation of atrial fibrillation? A prospective rhythm analysis in pacemaker patients with continuous atrial monitoring [J].
Steven, Daniel ;
Rostock, Thomas ;
Lutomsky, Boris ;
Klemm, Hanno ;
Servatius, Helge ;
Drewitz, Imke ;
Friedrichs, Kai ;
Ventura, Rodolfo ;
Meinertz, Thomas ;
Willems, Stephan .
EUROPEAN HEART JOURNAL, 2008, 29 (08) :1037-1042
[73]   Downloadable Algorithm to Reduce Inappropriate Shocks Caused by Fractures of Implantable Cardioverter-Defibrillator Leads [J].
Swerdlow, Charles D. ;
Gunderson, Bruce D. ;
Ousdigian, Kevin T. ;
Abeyratne, Athula ;
Stadler, Robert W. ;
Gillberg, Jeffrey M. ;
Patel, Amisha S. ;
Ellenbogen, Kenneth A. .
CIRCULATION, 2008, 118 (21) :2122-2129
[74]   MONITORING CHEST WITH IMPEDANCE [J].
VANDEWATER, JM ;
MOUNT, BE ;
BARELA, JR ;
SCHUSTER, R ;
LEACOCK, FS .
CHEST, 1973, 64 (05) :597-603
[75]  
Vardas P, 2004, HELL J CARDIOL, V45, P277
[76]   Detection of atrial fibrillation by implanted devices with wireless data transmission capability [J].
Varma, N ;
Stambler, B ;
Chun, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 :S133-S136
[77]   Rationale and design of a prospective study of the efficacy of a remote monitoring system used in implantable cardioverter defibrillator follow-up: The Lumos-T Reduces Routine Office Device Follow-Up Study (TRUST) Study [J].
Varma, Niraj .
AMERICAN HEART JOURNAL, 2007, 154 (06) :1029-1034
[78]   Patient Alert™ to detect ICD lead failure:: efficacy, limitations, and implications for future algorithms [J].
Vollmann, D ;
Erdogan, A ;
Himmrich, E ;
Neuzner, J ;
Becker, D ;
Unterberg-Buchwald, C ;
Sperzel, J .
EUROPACE, 2006, 8 (05) :371-376
[79]   Inappropriate therapy and fatal proarrhythmia by an implantable cardioverter-defibrittator [J].
Vollmann, D ;
Lüthje, L ;
Vonhof, S ;
Unterberg, C .
HEART RHYTHM, 2005, 2 (03) :307-309
[80]   Unusual cause for an increase of the sensing integrity counter in a patient with inappropriate implantable cardioverter-defibrittator therapy [J].
Vollmann, Dirk ;
Luethje, Lars ;
Zabel, Markus .
EUROPACE, 2007, 9 (05) :275-277