Improvement of oscilloscope based RE measurements by statistical averaging techniques

被引:22
作者
Fager, Christian
Andersson, Kristoffer
机构
来源
2006 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST, VOLS 1-5 | 2006年
关键词
statistical signal processing; digital storage oscilloscope; time domain measurement; base-band;
D O I
10.1109/MWSYM.2006.249565
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper demonstrates a method for accurate characterization of modulated microwave signals using a digital storage oscilloscope (DSO). Repeated measurements of the modulated signal are used with statistical averaging techniques to significantly improve the dynamic range. The performance of the method is evaluated by residual EVM and RF spectrum measurements. AM/AM measurements using two DSO channels are used to demonstrate the ability to perform synchronous input/output PA characterization.
引用
收藏
页码:1460 / 1463
页数:4
相关论文
共 6 条
[1]  
BLOCKLEY P, 2005, 2005 IEEE INT MICR S
[2]   A state-space modeling approach for dynamic nonlinear microwave system based on large signal time domain measurements [J].
Cidronali, A ;
Accillaro, C ;
Myslinski, M ;
Schreurs, D ;
Manes, G .
2005 IEEE MTT-S International Microwave Symposium, Vols 1-4, 2005, :477-480
[3]  
Kay SM, 1993, Fundamentals of Statistical Signal Processing
[4]  
Macraigne F, 2005, 35TH EUROPEAN MICROWAVE CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, P729
[5]  
MALLET A, 2002, MICR S 2002 IEEE MTT, V3, P2245
[6]  
WISELL D, 1940, INSTR MESA TECHN C 2, V2, P1177