Ball tipped guide wire for broken nail removal: a case report

被引:1
作者
Iqbal, Faizan [1 ]
Zamir, Mehroze [1 ]
Ahmed, Nasir [1 ]
Kamal, Syed Wajahat [1 ]
Memon, Nouman [1 ]
机构
[1] Patel Hosp, Dept Orthopaed Surg, Karachi 75300, Pakistan
来源
SICOT-J | 2021年 / 7卷
关键词
Femur fracture; Intramedullary nail; Union; Broken nail; Guidewire; RETRIEVAL; SEGMENT;
D O I
10.1051/sicotj/2021010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
A broken intramedullary nail is a well-known complication of non-union of femur shaft fractures. Numerous surgical techniques have been presented before in patients with non-union of long bone fractures. We report the surgical technique used to perform removal of the broken distal segment of a nail in a patient who achieved uneventful union after intramedullary nailing of closed femur shaft fracture. A ball-tipped guidewire was inserted through the broken segment of the femur nail. A pre-bend plain wire was then inserted. With the help of a vise-grip, both wires were twisted in order to make a secure handle between guidewires and a broken implant. With the help of a mallet upward-directed blows were applied to extract a broken segment of the nail. We found ball-tipped guidewire technique a useful and effective technique in removing the broken distal portion of the nail.
引用
收藏
页数:4
相关论文
共 13 条
[1]  
BUCHOLZ RW, 1987, J BONE JOINT SURG AM, V69A, P1391
[2]  
Jiang GQ., 2018, SICOT-J, V4, P1
[3]  
Kim DS., 1999, J KOREAN ORTHOP ASS, V34, P171
[4]   Removal of broken Kuntscher's nail: An innovative close technique [J].
Maini, L ;
Singh, J ;
Agarwal, P ;
Gautum, VK ;
Dhal, AK .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (06) :1518-1520
[5]   Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire [J].
Metikala, Sreenivasulu ;
Mohammed, Riazuddin .
INDIAN JOURNAL OF ORTHOPAEDICS, 2011, 45 (04) :347-350
[6]   RETRIEVAL AND REPLACEMENT OF A BROKEN KUNTSCHER ROD BY A CLOSED TECHNIQUE - TECHNICAL NOTE [J].
POEHLING, GG ;
WEBB, LX .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1982, 64 (09) :1389-1390
[7]  
Pongsamakthai Wanjak, 2016, J Clin Orthop Trauma, V7, P22, DOI 10.1016/j.jcot.2016.10.009
[8]   Removal of a broken intramedullary femoral nail with an unusual pattern of breakage: a case report [J].
Pretell Mazzini, Juan ;
Rodriguez Martin, Juan ;
Resines Erasun, Carlos .
STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2009, 4 (03) :151-155
[9]   Extended trochanteric osteotomy: comparison of 3 modes of fixation: metallic wires, cables, plate, about a series of 157 cases [J].
Prudhon, Jean Louis ;
Tardy, Nicolas .
SICOT-J, 2018, 4
[10]   A simple method for removal of a broken intramedullary nail [J].
Sivananthan, KS ;
Raveendran, K ;
Kumar, T ;
Sivananthan, S .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (06) :433-434