Improving energy flexibility of a net-zero energy house using a solar-assisted air conditioning system with thermal energy storage and demand-side management

被引:55
作者
Ren, Haoshan [1 ,2 ]
Sun, Yongjun [1 ]
Albdoor, Ahmed K. [2 ,3 ]
Tyagi, V. V. [4 ]
Pandey, A. K. [5 ]
Ma, Zhenjun [2 ]
机构
[1] City Univ Hong Kong, Div Bldg Sci & Technol, Hong Kong, Peoples R China
[2] Univ Wollongong, Sustainable Bldg Res Ctr, Wollongong, NSW 2522, Australia
[3] Southern Tech Univ, Al Nasiriyah Tech Inst, Dept Mech Tech, Thi Qar, Iraq
[4] Shri Mata Vaishno Devi Univ, Sch Energy Management, Katra 182320, J&K, India
[5] Sunway Univ, Sch Engn & Technol, Res Ctr Nanomat & Energy Technol, Subang Jaya 47500, Selangor, Malaysia
关键词
Energy flexibility; Photovoltaic; thermal collector; Phase change material; Thermal energy storage; Net-zero energy house;
D O I
10.1016/j.apenergy.2021.116433
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The increasing penetration of solar energy into buildings can mitigate the great challenges of energy shortage and global warming, while the inherent intermittence of solar energy could endanger power grids. This study investigated the energy flexibility of a net-zero energy (NZE) house using a solar-assisted air conditioning system with integrated thermal energy storage (TES) and demand-side management (DSM) strategies. The main contribution is to investigate and reveal the interactions among the utilisation of solar energy, thermal energy storage, and DSM strategies, to improve building energy flexibility. A simulation system of the NZE house was first developed using TRNSYS. A total of 40 alternative designs of the solar-assisted air conditioning system with TES were formulated by exhausting the combination of the photovoltaic/thermal (PV/T) collectors and a phase change material TES unit, and four DSM strategies including over-heating/cooling, pre-heating/cooling, temperature set-point relaxation, and heat pump charging TES. The results showed that heat pump solar contribution (i.e. the ratio of the energy consumption provided by PV to its total energy consumption) of 0.79 was achieved by using DSM strategies. Using TES unit could further increase solar contribution to nearly 1.0. The influence of the temperature set-point relaxation and over-heating/cooling strategies on energy flexibility was negligible when the over-heating/cooling and/or heat pump charging TES were used. The 1% peak grid import was mostly contributed by the appliances when the designs with high energy flexibility were used. The findings of this study could be used to facilitate the development of NZE buildings with increased energy flexibility.
引用
收藏
页数:20
相关论文
共 48 条
  • [1] Demand side flexibility: Potentials and building performance implications
    Aduda, K. O.
    Labeodan, T.
    Zeiler, W.
    Boxem, G.
    Zhao, Y.
    [J]. SUSTAINABLE CITIES AND SOCIETY, 2016, 22 : 146 - 163
  • [2] Comparison of four rule-based demand response control algorithms in an electrically and heat pump-heated residential building
    Alimohammadisagvand, Behrang
    Jokisalo, Juha
    Siren, Kai
    [J]. APPLIED ENERGY, 2018, 209 : 167 - 179
  • [3] Cost-optimal thermal energy storage system for a residential building with heat pump heating and demand response control
    Alimohammadisagvand, Behrang
    Jokisalo, Juha
    Kilpelainen, Simo
    Ali, Mubbashir
    Siren, Kai
    [J]. APPLIED ENERGY, 2016, 174 : 275 - 287
  • [4] [Anonymous], 2009, 2009 ASHRAE HDB FUND
  • [5] [Anonymous], 2013, NRELTP550056354
  • [6] Ausgrid, 2020, Time of Use Pricing
  • [7] Australian GEMS Regulator, EN RAT CALC 2020
  • [8] Canstar Blue, 2019, GUID NEW S WAL EL TA
  • [9] Community-scale residential air conditioning control for effective grid management
    Cole, Wesley J.
    Rhodes, Joshua D.
    Gorman, William
    Perez, Krystian X.
    Webber, Michael E.
    Edgar, Thomas F.
    [J]. APPLIED ENERGY, 2014, 130 : 428 - 436
  • [10] Commonwealth of Australia, 2012, WAT HEAT DAT COLL AN