Tailoring of Magnetic Softness and Magnetoimpedance of Co-Rich Microwires by Stress Annealing

被引:16
作者
Zhukov, Arcady [1 ,2 ,3 ]
Gonzalez-Legarreta, Lorena [4 ]
Corte-Leon, Paula [1 ,3 ]
Ipatov, Mihail [1 ,3 ]
Maria Blanco, Juan [3 ]
Gonzalez, Julian [1 ]
Zhukova, Valentina [3 ]
机构
[1] Univ Basque Country, UPV EHU, Fac Quim, Dept Polimeros & Mat Avanzados Fis Quim & Tecnol, San Sebastian 20018, Spain
[2] Ikerbasque, Basque Fdn Sci, Bilbao 48011, Spain
[3] Univ Basque Country, UPV EHU, EIG, Dept Fis Aplicada, San Sebastian 20018, Spain
[4] Univ Cantabria, Dept QUIPRE, Nanomed IDIVAL, Inorgan Chem, Avda Castros 46, Santander 39005, Spain
来源
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE | 2021年 / 218卷 / 12期
关键词
annealing; giant magnetoimpedance; internal stresses; magnetic microwires; magnetoelastic anisotropy; MECHANICAL-PROPERTIES; AMORPHOUS WIRES; GMI; IMPEDANCE; ANISOTROPY; SENSORS; FIELD; MAGNETORESISTANCE; ALLOYS;
D O I
10.1002/pssa.202100130
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Herein, detailed studies on the influence of stress annealing on the magnetic softness and giant magnetoimpedance (GMI) ratio of Co69.2Fe3.6Ni1B12.5Si11Mo1.5C1.2 glass-coated microwires are provided. As-prepared microwire presents linear hysteresis loops, moderate GMI ratio with double-peak magnetic field dependence and low coercivity (4 A m(-1)), typically observed for wires with transverse magnetic anisotropy. However, after conventional annealing magnetic hardening and transformation of linear hysteresis loop into rectangular with coercivity about 90 A m(-1) is surprisingly observed. It is shown that stress annealing allows preventing magnetic hardening and remarkably improving GMI ratio. Properly stress-annealed samples present better magnetic softness: almost unhysteretic loops with coercivity about 2 A m(-1) and magnetic anisotropy field about 35 A m(-1). Observed stress-annealing-induced anisotropy is affected by the tensile stresses, applied during annealing and by the annealing temperature. From the frequency dependence of the maximum GMI ratio, the optimum frequency ranges for as-prepared and stress-annealed samples are determined. The observed stress-annealing-induced magnetic anisotropy and associated changes in magnetic properties and GMI effect are discussed in terms of internal stresses relaxation and related modification of the magnetostriction coefficient, "back stresses," structural anisotropy, redistribution of internal stresses, and change of spatial distribution of magnetic anisotropy.
引用
收藏
页数:11
相关论文
共 70 条
[31]   MAGNETOSTRICTION MEASUREMENTS FOR AMORPHOUS WIRES [J].
KONNO, Y ;
MOHRI, K .
IEEE TRANSACTIONS ON MAGNETICS, 1989, 25 (05) :3623-3625
[32]   Biomedical applications of glass-coated microwires [J].
Kozejova, D. ;
Fecova, L. ;
Klein, P. ;
Sabol, R. ;
Hudak, R. ;
Sulla, I. ;
Mudronova, D. ;
Galik, J. ;
Varga, R. .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2019, 470 :2-5
[33]   Temperature memory effect of stress annealing-induced anisotropy in metallic glasses [J].
Kozikowski, Pawel ;
Ohnuma, Masato ;
Hashimoto, Ryuichi ;
Takano, Kodai ;
Herzer, Giselher ;
Kuhnt, Markus ;
Polak, Christian .
PHYSICAL REVIEW MATERIALS, 2020, 4 (09)
[34]   FERROMAGNETIC-RESONANCE IN AMORPHOUS ALLOYS PREPARED BY RAPID QUENCHING FROM MELT [J].
KRAUS, L ;
SCHNEIDER, J ;
WIESNER, H .
CZECHOSLOVAK JOURNAL OF PHYSICS, 1976, 26 (05) :601-602
[35]   Theory of giant magneto-impedance in the planar conductor with uniaxial magnetic anisotropy [J].
Kraus, L .
JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 1999, 195 (03) :764-778
[36]   Magnetic sensors and their applications [J].
Lenz, James ;
Edelstein, Alan S. .
IEEE SENSORS JOURNAL, 2006, 6 (03) :631-649
[37]   Enhancing GMI properties of melt-extracted Co-based amorphous wires by twin-zone Joule annealing [J].
Liu, J. S. ;
Cao, F. Y. ;
Xing, D. W. ;
Zhang, L. Y. ;
Qin, F. X. ;
Peng, H. X. ;
Xue, X. ;
Sun, J. F. .
JOURNAL OF ALLOYS AND COMPOUNDS, 2012, 541 :215-221
[38]  
LUBORSKY FE, 1977, IEEE T MAGN, V13, P953, DOI 10.1109/TMAG.1977.1059494
[39]   Development of high resolution programmable oversampling MI sensor system with 32-bit ADC for multi-channel bio-magnetic measurements [J].
Ma, J. ;
Yang, Z. ;
Uchiyama, T. .
AIP ADVANCES, 2019, 9 (12)
[40]  
Makhnovskiy D, 2009, ADV SCI TECH, V54, P201