Characterization of a single photon counting imaging system by transfer function analysis

被引:2
作者
Bisogni, M. G. [1 ]
Carpentieri, C.
Delogu, P.
Fantacci, M. E.
Novelli, M.
Quattrocchi, M.
Retico, A.
Rosso, V.
Stefanini, A.
机构
[1] Univ Pisa, Dipartimento Fis, I-56127 Pisa, Italy
[2] Sez INFN Pisa, I-56127 Pisa, Italy
[3] IRST, ITC, Ctr Ric Sci & Tecnol, I-38050 Trento, Italy
关键词
contrast transfer function (CTF); detective quantum efficiency (DQE); digital radiography; medical imaging equipment; modulation transfer function (MTF); solid-state detectors;
D O I
10.1109/TNS.2006.889170
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A method to quantitatively evaluate the performances of a radiographic detection system consists in measuring the contrast, noise and modulation transfer functions. These functions have been evaluated for a digital radiographic system based on a single photon counting pixel detector. The X-ray detector is a Silicon sensor with one side segmented in a matrix of 256 by 256 square contacts with a pitch of 55 mu m. The active area is about 2 cm(2). The sensor is connected to the Medipix2 read-out chip by bump-bonding. As X-ray source we have used a tube for general radiography. To reproduce the conditions of a radiographic examination, a 4 cm thick Incite block positioned above the detector has been used to simulate a tissue sample. To study the Contrast Transfer Function we have measured the contrast of an 1 mm thick lead slab with respect to the background. To evaluate the scattering contribution from the Incite, the measurements have been performed with and without a collimator placed at the beam exit. To assess the efficiency and noise transfer properties, we have measured the Detective Quantum Efficiency (DQE) of. the detector as a function of the tube voltage. The Modulation Transfer Function has been measured applying the slit method for different conditions of tube voltage and energy threshold.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 50 条
  • [41] Simulation analysis on the performance of a circular-edge technique in measurements of the modulation transfer function
    Maruyama, Sho
    JOURNAL OF MEDICAL PHYSICS, 2023, 48 (01) : 90 - 97
  • [42] Characterization of anti-scatter grids via a modulation transfer function improvement factor using an edge device
    Maruyama, Sho
    Saito, Hiroki
    Shimosegawa, Masayuki
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (04)
  • [43] Validity of the line-pair bar-pattern method in the measurement of the modulation transfer function (MTF) in megavoltage imaging
    Gopal, A.
    Samant, S. S.
    MEDICAL PHYSICS, 2008, 35 (01) : 270 - 279
  • [44] Accuracy of a simple method for deriving the presampled modulation transfer function of a digital radiographic system from an edge image
    Buhr, E
    Günther-Kohfahl, S
    Neitzel, U
    MEDICAL PHYSICS, 2003, 30 (09) : 2323 - 2331
  • [45] Modulation transfer function analysis of silicon X-ray sensor with trench-structured photodiodes
    Ariyoshi, Tetsuya
    Iwasa, Jumpei
    Takane, Yuta
    Sakamoto, Kenji
    Baba, Akiyoshi
    Arima, Yutaka
    IEICE ELECTRONICS EXPRESS, 2018, 15 (11): : 1 - 6
  • [46] Calculating the modulation transfer function of an optical imaging system incorporating a digital camera from slanted-edge images captured under variable illumination levels: Fourier transforms application using MATLAB
    Alaruri, Sami D.
    OPTIK, 2016, 127 (15): : 5820 - 5824
  • [47] Diagnostic Performance of a Prototype Dual-Energy Chest Imaging System: ROC Analysis
    Kashani, Hany
    Varon, Carlos A.
    Paul, Narinder S.
    Gang, Grace J.
    Van Metter, Rich
    Yorkston, John
    Siewerdsen, Jeffrey H.
    ACADEMIC RADIOLOGY, 2010, 17 (03) : 298 - 308
  • [48] A comprehensive model for x-ray projection imaging system efficiency and image quality characterization in the presence of scattered radiation
    Monnin, P.
    Verdun, F. R.
    Bosmans, H.
    Perez, S. Rodriguez
    Marshall, N. W.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (14) : 5691 - 5722
  • [49] EFFECTS OF UNDERSAMPLING ON THE PROPER INTERPRETATION OF MODULATION TRANSFER-FUNCTION, NOISE POWER SPECTRA, AND NOISE EQUIVALENT QUANTA OF DIGITAL IMAGING-SYSTEMS
    DOBBINS, JT
    MEDICAL PHYSICS, 1995, 22 (02) : 171 - 181
  • [50] Analysis of the kinestatic charge detection system as a high detective quantum efficiency electronic portal imaging device
    Samant, Sanjiv S.
    Gopal, Arun
    MEDICAL PHYSICS, 2006, 33 (09) : 3557 - 3567