Do Additional Echocardiographic Variables Increase the Accuracy of E/e′ for Predicting Left Ventricular Filling Pressure in Normal Ejection Fraction? An Echocardiographic and Invasive Hemodynamic Study

被引:53
作者
Dokainish, Hisham [1 ]
Nguyen, John S. [1 ]
Sengupta, Ranjita [1 ]
Pillai, Manu [1 ]
Alam, Mahboob [1 ]
Bobek, Jaromir [1 ]
Lakkis, Nasser [1 ]
机构
[1] Baylor Coll Med, Dept Med, Cardiol Sect, Houston, TX 77030 USA
关键词
Diastolic function; Doppler tissue imaging; Hemodynamics; DIASTOLIC HEART-FAILURE; TISSUE DOPPLER-ECHOCARDIOGRAPHY; LEFT ATRIAL VOLUME; NATRIURETIC PEPTIDE; SYSTOLIC FUNCTION; DIAGNOSIS; DYSFUNCTION; GUIDELINES; EXERCISE; RECOMMENDATIONS;
D O I
10.1016/j.echo.2009.11.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: There are few data on adding left atrial volume index (LAVi) or pulmonary artery systolic pressure (PAP) to the ratio of early mitral inflow to mitral annular velocity (E/e') for the estimation of left ventricular (LV) filling pressure in patients with preserved LV ejection fractions (LVEFs) (>50%). Methods: Patients underwent echocardiography within 20 minutes of cardiac catheterization. Echocardiographic variables were compared with invasively measured LV preatrial contraction pressure (pre-A). Results: Of the 122 patients studied (mean age, 55+/-9 years; mean LVEF, 61+/-6%), 67 (55%) were women, 108 (88%) had hypertension, and 79 (65%) had significant coronary artery disease at catheterization. E/e' was significantly correlated with pre-A (R = 0.63, P < .0001) compared with LAVi (R = 0.49, P < .001) and PAP (R = 0.48, P < .001). E/e' > 13 had sensitivity of 70% and specificity of 93% (area under the curve [AUC], 0.82; P < .0001), LAVi > 31 mL/m(2) had sensitivity of 78% and specificity of 76% (AUC, 0.80, P < .001), and PAP > 28 mm Hg had sensitivity of 80% and specificity of 64% for pre-A > 15 mm Hg (AUC, 0.77, P < .001). Adding LAVi > 31 mL/m(2) for E/e' = 8 to 13 significantly increased the accuracy of E/e' > 13 alone (sensitivity, 87%; specificity, 88%; AUC, 0.89; P = .01 for comparison). However, adding PAP > 28 mm Hg for E/e' = 8 to 13 did not significantly increase the accuracy of E/e' > 13 alone (AUC, 0.82; sensitivity, 82%; specificity, 72%; P = NS for comparison). Conclusions: In patients with preserved LVEFs, adding LAVi > 31 mL/m(2) to E/e' (when E/e' was in the gray zone, but not when E/e' was > 13) significantly increased the accuracy of E/e' alone for the estimation of LV filling pressure. These data support the notion of using several, rather than any single, Doppler echocardiographic parameter for the accurate assessment of LV diastolic function. (J Am Soc Echocardiogr 2010;23:156-61.)
引用
收藏
页码:156 / 161
页数:6
相关论文
共 38 条
[1]   Left atrial size - Physiologic determinants and clinical applications [J].
Abhayaratna, Walter P. ;
Seward, James B. ;
Appleton, Christopher P. ;
Douglas, Pamela S. ;
Oh, Jae K. ;
Tajik, A. Jamil ;
Tsang, Teresa S. M. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (12) :2357-2363
[2]   ESTIMATION OF LEFT-VENTRICULAR FILLING PRESSURES USING 2-DIMENSIONAL AND DOPPLER-ECHOCARDIOGRAPHY IN ADULT PATIENTS WITH CARDIAC DISEASE - ADDITIONAL VALUE OF ANALYZING LEFT ATRIAL SIZE, LEFT ATRIAL EJECTION FRACTION AND THE DIFFERENCE IN DURATION OF PULMONARY VENOUS AND MITRAL FLOW VELOCITY AT ATRIAL CONTRACTION [J].
APPLETON, CP ;
GALLOWAY, JM ;
GONZALEZ, MS ;
GABALLA, M ;
BASNIGHT, MA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 22 (07) :1972-1982
[3]   Comparative accuracy of color M-mode and tissue Doppler echocardiography in the emergency diagnosis of congestive heart failure in chronic hypertensive patients with normal left ventricular ejection fraction [J].
Arques, S ;
Roux, E ;
Sbragia, P ;
Gelisse, R ;
Ambrosi, P ;
Pieri, B ;
Luccioni, R .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (10) :1456-1459
[4]   Diastolic heart failure [J].
Maurer, MS ;
Packer, M ;
Burkhoff, D .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (11) :1143-1143
[5]   Usefulness of the pulmonary arterial systolic pressure to predict pulmonary arterial wedge pressure in patients with normal left ventricular systolic function [J].
Bouchard, Joseph L. ;
Aurigemma, Gerard P. ;
Hill, Jeffrey C. ;
Ennis, Cynthia A. ;
Tighe, Dennis A. .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (11) :1673-1676
[6]   Usefulness of tissue Doppler imaging for estimation of left ventricular filling pressures in patients with systolic and diastolic heart failure [J].
Bruch, C ;
Grude, M ;
Müller, J ;
Breithardt, G ;
Wichter, T .
AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (07) :892-895
[7]   Systolic and diastolic heart failure in the community [J].
Bursi, Francesca ;
Weston, Susan A. ;
Redfield, Margaret M. ;
Jacobsen, Steven J. ;
Pakhomov, Serguei ;
Nkomo, Vuyisile T. ;
Meverden, Ryan A. ;
Roger, Veronique L. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (18) :2209-2216
[8]   Left Ventricular Filling Pressure Estimation at Rest and During Exercise in Patients With Severe Aortic Valve Stenosis: Comparison of Echocardiographic and Invasive Measurements [J].
Dalsgaard, Morten ;
Kjaergaard, Jesper ;
Pecini, Redi ;
Iversen, Kasper Karmark ;
Kober, Lars ;
Moller, Jacob Eifer ;
Grande, Peer ;
Clemmensen, Peter ;
Hassager, Christian .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (04) :343-349
[9]   ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure 2008 [J].
Dickstein, Kenneth ;
Cohen-Solal, Alain ;
Filippatos, Gerasimos ;
McMurray, John J. V. ;
Ponikowski, Piotr ;
Poole-Wilson, Philip Alexander ;
Stromberg, Anna ;
van Veldhuisen, Dirk J. ;
Atar, Dan ;
Hoes, Arno W. ;
Keren, Andre ;
Mebazaa, Alexandre ;
Nieminen, Markku ;
Priori, Silvia Giuliana ;
Swedberg, Karl .
EUROPEAN HEART JOURNAL, 2008, 29 (19) :2388-2442
[10]   Optimal noninvasive assessment of left ventricular filling pressures - A comparison of tissue Doppler echocardiography and B-type natriuretic peptide in patients with pulmonary artery catheters [J].
Dokainish, H ;
Zoghbi, WA ;
Lakkis, NM ;
Al-Bakshy, F ;
Dhir, M ;
Quinones, MA ;
Nagueh, SF .
CIRCULATION, 2004, 109 (20) :2432-2439