Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition

被引:452
作者
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
Ropers, Dieter [1 ]
Schepis, Tiziano [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Daniel, Werner G. [1 ]
Uder, Michael [2 ]
Lell, Michael M. [2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
关键词
Computed tomography; Coronary CT angiography; Dual-source CT; Radiation exposure; IMAGE QUALITY; CT ANGIOGRAPHY; RADIATION-EXPOSURE; AMERICAN-COLLEGE; GUIDELINES; MANAGEMENT; REDUCTION; COMMITTEE; ANGINA; UPDATE;
D O I
10.1093/eurheartj/ehp470
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. In 50 consecutive patients (body weight < 100 kg, sinus rhythm < 60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'. In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 50 条
  • [31] Detection of coronary artery stenosis with sub-milliSievert radiation dose by prospectively ECG-triggered high-pitch spiral CT angiography and iterative reconstruction
    Yin, Wei-Hua
    Lu, Bin
    Hou, Zhi-Hui
    Li, Nan
    Han, Lei
    Wu, Yong-Jian
    Niu, Hong-Xia
    Silverman, Justin R.
    De Cecco, Carlo Nicola
    Schoepf, U. Joseph
    EUROPEAN RADIOLOGY, 2013, 23 (11) : 2927 - 2933
  • [32] Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose <0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction
    Annika Schuhbaeck
    Stephan Achenbach
    Christian Layritz
    Jasmin Eisentopf
    Franziska Hecker
    Tobias Pflederer
    Soeren Gauss
    Johannes Rixe
    Willi Kalender
    Werner G. Daniel
    Michael Lell
    Dieter Ropers
    European Radiology, 2013, 23 : 597 - 606
  • [33] Image quality, radiation dose, and diagnostic accuracy of prospectively ECG-triggered high-pitch coronary CT angiography at 70 kVp in a clinical setting: comparison with invasive coronary angiography
    Zhang, Long Jiang
    Wang, Yining
    Schoepf, U. Joseph
    Meinel, Felix G.
    Bayer, Richard R., II
    Qi, Li
    Cao, Jian
    Zhou, Chang Sheng
    Zhao, Yan E.
    Li, Xie
    Bin Gong, Jian
    Jin, Zhengyu
    Lu, Guang Ming
    EUROPEAN RADIOLOGY, 2016, 26 (03) : 797 - 806
  • [34] Ultra-fast, low dose high-pitch (FLASH) versus prospectively-gated coronary computed tomography angiography: Comparison of image quality and patient radiation exposure
    Smettei, Osama A.
    Sayed, Sawsan
    Al Habib, Abdullah M.
    Alharbi, Fahad
    Abazid, Rami M.
    JOURNAL OF THE SAUDI HEART ASSOCIATION, 2018, 30 (03) : 165 - 171
  • [35] High-Pitch Dual-Source Computed Tomography Renal Angiography Comparison With Conventional Low-Pitch Computed Tomography Angiography: Image Quality, Contrast Medium Volume, and Radiation Dose
    Pang, LiFang
    Zhao, Yue
    Dong, HaiPeng
    Shi, HongCheng
    Yang, WenJie
    Zhang, Huan
    Yan, FuHua
    Liu, Bo
    Yan, Jing
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (05) : 737 - 740
  • [36] A prospective randomized trial comparing image quality, study interpretability, and radiation dose of narrow acquisition window with widened acquisition window protocols in prospectively ECG-triggered coronary computed tomography angiography
    Leipsic, Jonathon
    LaBounty, Troy M.
    Ajlan, Amr M.
    Earls, James P.
    Strovski, E.
    Madden, Mark
    Wood, David A.
    Hague, Cameron J.
    Poulter, Rohan
    Branch, Kelly
    Cury, Ricardo C.
    Heilbron, Brett
    Taylor, Carolyn
    Grunau, Gilat
    Haiducu, Lawrence
    Min, James K.
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2013, 7 (01) : 18 - 24
  • [37] Image quality and dose performance of 80 kV low dose scan protocol in high-pitch spiral coronary CT angiography: feasibility study
    Dan Wang
    Xiu-hua Hu
    Shi-zheng Zhang
    Run-ze Wu
    Su-su Xie
    Bin Chen
    Qiao-wei Zhang
    The International Journal of Cardiovascular Imaging, 2012, 28 : 415 - 423
  • [38] Prospective-triggered high-pitch spiral versus sequential dual-source CT coronary angiography: comparison of image quality and radiation dose
    Zhuang, Y.
    Huang, W.
    Shi, Y.
    Bo, G.
    Lu, D.
    Zhang, J.
    Kong, D.
    Shit, Y.
    Wang, B.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2018, 16 (02): : 225 - 233
  • [39] Radiation doses from phantom measurements at high-pitch dual-source computed tomography coronary angiography
    Goetti, Robert
    Leschka, Sebastian
    Boschung, Markus
    Mayer, Sabine
    Wyss, Christophe
    Stolzmann, Paul
    Frauenfelder, Thomas
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : 773 - 779
  • [40] Prospectively ECG-triggered high-pitch 80kVp coronary computed tomography angiography with 30mL of 270mg I/mL contrast material and iterative reconstruction
    Qi, Li
    Wu, Sheng Yong
    Meinel, Felix G.
    Zhou, Chang Sheng
    Wang, Qing Qing
    McQuiston, Andrew D.
    Ji, Xue Man
    Schoepf, U. Joseph
    Lu, Guang Ming
    Zhang, Long Jiang
    ACTA RADIOLOGICA, 2016, 57 (03) : 287 - 294