Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition

被引:452
|
作者
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
Ropers, Dieter [1 ]
Schepis, Tiziano [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Daniel, Werner G. [1 ]
Uder, Michael [2 ]
Lell, Michael M. [2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
关键词
Computed tomography; Coronary CT angiography; Dual-source CT; Radiation exposure; IMAGE QUALITY; CT ANGIOGRAPHY; RADIATION-EXPOSURE; AMERICAN-COLLEGE; GUIDELINES; MANAGEMENT; REDUCTION; COMMITTEE; ANGINA; UPDATE;
D O I
10.1093/eurheartj/ehp470
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. In 50 consecutive patients (body weight < 100 kg, sinus rhythm < 60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'. In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 50 条
  • [21] Computed tomography pulmonary angiography using high-pitch dual-source scanner technology
    Al Hassan, Donya A.
    Waheed, Khawaja B.
    El Sirafy, Mohamed N.
    Khattab, Mohamad A.
    Al-Hammadi, Hassan I.
    Ibrahim, Motassem F.
    Ibrahim, Motassem F.
    Arulanantham, Zechariah J.
    SAUDI MEDICAL JOURNAL, 2019, 40 (03) : 230 - 237
  • [22] High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose
    Bogaard, Kjell
    van der Zant, Friso M.
    Knol, Remco J. J.
    Reinders, Sjoerd
    Krul, Marije M. G.
    van Rossum, Albert C.
    Knaapen, Paul
    Cornel, Jan H.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2015, 31 (01) : 125 - 133
  • [23] Non-Electrocardiogram-Triggered 70-kVp High-Pitch Computed Tomography Angiography of the Whole Aorta With Iterative Reconstruction: Initial Results
    Zhang, Long Jiang
    Li, Xie
    Schoepf, U. Joseph
    Wichmann, Julian L.
    Tang, Chun Xiang
    Zhou, Chang Sheng
    Lu, Guang Ming
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (01) : 109 - 117
  • [24] Visualization of proximal coronary arteries on high-pitch electrocardiogram-triggered computed tomography in pediatric congenital heart disease: effects of heart rate and body surface area
    LaDonna J. Malone
    Andrew Olson
    Alex J. Barker
    David Andrew Mong
    Jason P. Weinman
    Lorna P. Browne
    Pediatric Radiology, 2020, 50 : 1375 - 1380
  • [25] Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose &lt;0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction
    Schuhbaeck, Annika
    Achenbach, Stephan
    Layritz, Christian
    Eisentopf, Jasmin
    Hecker, Franziska
    Pflederer, Tobias
    Gauss, Soeren
    Rixe, Johannes
    Kalender, Willi
    Daniel, Werner G.
    Lell, Michael
    Ropers, Dieter
    EUROPEAN RADIOLOGY, 2013, 23 (03) : 597 - 606
  • [26] Low-Concentration Contrast Medium for 128-Slice Dual-Source CT Coronary Angiography at a Very Low Radiation Dose Using Prospectively ECG-Triggered High-Pitch Spiral Acquisition
    Zheng, Minwen
    Wu, Yongjie
    Wei, Mengqi
    Liu, Ying
    Zhao, Hongliang
    Li, Jian
    ACADEMIC RADIOLOGY, 2015, 22 (02) : 195 - 202
  • [27] Image quality and radiation dose of a prospectively electrocardiography-triggered high-pitch data acquisition strategy for coronary CT angiography: The multicenter, randomized PROTECTION IV study
    Deseive, Simon
    Pugliese, Francesca
    Meave, Aloha
    Alexanderson, Erick
    Martinoff, Stefan
    Hadamitzky, Martin
    Massberg, Steffen
    Hausleiter, Joerg
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2015, 9 (04) : 278 - 285
  • [28] 128-slice Dual-source Computed Tomography Coronary Angiography in Patients with Atrial Fibrillation: Image Quality and Radiation Dose of Prospectively Electrocardiogram-triggered Sequential Scan Compared with Retrospectively Electrocardiogram-gated Spiral
    Lu Lin
    Yi-ning Wang
    Ling-yan Kong
    Zheng-yu Jin
    Guang-ming Lu
    Zhao-qi Zhang
    Jian Cao
    Shuo Li
    Lan Song
    Zhi-wei Wang
    Kang Zhou
    Ming Wang
    ChineseMedicalSciencesJournal, 2012, 27 (04) : 195 - 200
  • [29] Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography
    Gordic, Sonja
    Desbiolles, Lotus
    Sedlmair, Martin
    Manka, Robert
    Plass, Andre
    Schmidt, Bernhard
    Husarik, Daniela B.
    Maisano, Francesco
    Wildermuth, Simon
    Alkadhi, Hatem
    Leschka, Sebastian
    EUROPEAN RADIOLOGY, 2016, 26 (02) : 459 - 468
  • [30] High-pitch prospective ECG-triggered helical coronary computed tomography angiography in clinical practice: image quality and radiation dose
    Kjell Bogaard
    Friso M. van der Zant
    Remco J. J. Knol
    Sjoerd Reinders
    Marije M. G. Krul
    Albert C. van Rossum
    Paul Knaapen
    Jan H. Cornel
    The International Journal of Cardiovascular Imaging, 2015, 31 : 125 - 133