Coronary computed tomography angiography with a consistent dose below 1 mSv using prospectively electrocardiogram-triggered high-pitch spiral acquisition

被引:452
|
作者
Achenbach, Stephan [1 ]
Marwan, Mohamed [1 ]
Ropers, Dieter [1 ]
Schepis, Tiziano [1 ]
Pflederer, Tobias [1 ]
Anders, Katharina [2 ]
Kuettner, Axel [2 ]
Daniel, Werner G. [1 ]
Uder, Michael [2 ]
Lell, Michael M. [2 ]
机构
[1] Univ Erlangen Nurnberg, Dept Cardiol, D-91054 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Inst Radiol, D-91054 Erlangen, Germany
关键词
Computed tomography; Coronary CT angiography; Dual-source CT; Radiation exposure; IMAGE QUALITY; CT ANGIOGRAPHY; RADIATION-EXPOSURE; AMERICAN-COLLEGE; GUIDELINES; MANAGEMENT; REDUCTION; COMMITTEE; ANGINA; UPDATE;
D O I
10.1093/eurheartj/ehp470
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We evaluated the feasibility and image quality of a new scan mode for coronary computed tomography angiography (CTA) with an effective dose of less than 1 mSv. In 50 consecutive patients (body weight < 100 kg, sinus rhythm < 60 b.p.m. after pre-medication, coronary CTA was performed using a dual-source CT system with 2 x 128 x 0.6 mm collimation, 0.28 s rotation time, a pitch of 3.2 or 3.4, 100 kV tube voltage and current of 320 mA s. Data acquisition was prospectively triggered at 60% of the R-R interval and completed within one cardiac cycle. Image quality was evaluated using a four-point scale (1 = absence of any artefacts to 4 = uninterpretable). In all 50 patients, imaging was successful. Mean duration of data acquisition was 258 +/- 20 ms. Mean dose-length product was 62 +/- 5 mGy cm, the effective dose was 0.87 +/- 0.07 mSv (0.78-0.99 mSv). Of the 742 coronary artery segments, 94% had an image quality score of 1, 5.0% a score of 2, 0.9% a score of 3, and 4 segments (0.5%) were 'uninterpretable'. In non-obese patients with a low and stable heart rate, prospectively ECG-triggered high-pitch spiral coronary CTA provides excellent image quality at a consistent dose below 1.0 mSv.
引用
收藏
页码:340 / 346
页数:7
相关论文
共 50 条
  • [1] Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experience
    Wang, Qi
    Qin, Jing
    He, Bai
    Zhou, Yin
    Yang, Jun-jie
    Hou, Xiao-ling
    Yang, Xiao-bo
    Chen, Jiu-hong
    Chen, Yun-dai
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (06) : 1341 - 1349
  • [2] Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experience
    Qi Wang
    Jing Qin
    Bai He
    Yin Zhou
    Jun-jie Yang
    Xiao-ling Hou
    Xiao-bo Yang
    Jiu-hong Chen
    Yun-dai Chen
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1341 - 1349
  • [3] High-Pitch Electrocardiogram-Triggered Computed Tomography of the Chest Initial Results
    Lell, Michael
    Hinkmann, Fabian
    Anders, Katharina
    Deak, Paul
    Kalender, Willi A.
    Uder, Michael
    Achenbach, Stephan
    INVESTIGATIVE RADIOLOGY, 2009, 44 (11) : 728 - 733
  • [4] Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience
    Lell, Michael
    Marwan, Mohamed
    Schepis, Tiziano
    Pflederer, Tobias
    Anders, Katharina
    Flohr, Thomas
    Allmendinger, Thomas
    Kalender, Willi
    Ertel, Dirk
    Thierfelder, Carsten
    Kuettner, Axel
    Ropers, Dieter
    Daniel, Werner G.
    Achenbach, Stephan
    EUROPEAN RADIOLOGY, 2009, 19 (11) : 2576 - 2583
  • [5] Detection of Coronary Artery Stenoses by Low-Dose, Prospectively ECG-Triggered, High-Pitch Spiral Coronary CT Angiography
    Achenbach, Stephan
    Goroll, Tobias
    Seltmann, Martin
    Pflederer, Tobias
    Anders, Katharina
    Ropers, Dieter
    Daniel, Werner G.
    Uder, Michael
    Lell, Michael
    Marwan, Mohamed
    JACC-CARDIOVASCULAR IMAGING, 2011, 4 (04) : 328 - 337
  • [6] Prospectively ECG-triggered high-pitch spiral acquisition for coronary CT angiography using dual source CT: technique and initial experience
    Michael Lell
    Mohamed Marwan
    Tiziano Schepis
    Tobias Pflederer
    Katharina Anders
    Thomas Flohr
    Thomas Allmendinger
    Willi Kalender
    Dirk Ertel
    Carsten Thierfelder
    Axel Kuettner
    Dieter Ropers
    Werner G. Daniel
    Stephan Achenbach
    European Radiology, 2009, 19 : 2576 - 2583
  • [7] Reduction of radiation dose for coronary computed tomography angiography using prospective electrocardiography-triggered high-pitch acquisition in clinical routine
    Chaosuwannakit, Narumol
    Makarawate, Pattarapong
    POLISH JOURNAL OF RADIOLOGY, 2018, 83 : E260 - E267
  • [8] Safety and efficacy of intravenous esmolol before prospective electrocardiogram- triggered high-pitch spiral acquisition for computed tomography coronary angiography
    Wang, Jin-Da
    Zhang, Hua-Wei
    Xin, Qian
    Yang, Jun-Jie
    Sun, Zhi-Jun
    Liu, Hong-Bin
    Chen, Lian
    Du, Luo-Shan
    Chen, Yun-Dai
    JOURNAL OF GERIATRIC CARDIOLOGY, 2014, 11 (01) : 39 - 43
  • [9] Low-dose, Prospective Triggered High-pitch Spiral Coronary Computed Tomography Angiography: Comparison with Retrospective Spiral Technique
    Srichai, Monvadi B.
    Lim, Ruth P.
    Donnino, Robert
    Mannelli, Lorenzo
    Hiralal, Rajesh
    Avery, Ryan
    Ho, Corey
    Babb, James S.
    Jacobs, Jill E.
    ACADEMIC RADIOLOGY, 2012, 19 (05) : 554 - 561
  • [10] Double prospectively ECG-triggered high-pitch spiral acquisition for CT coronary angiography: Initial experience
    Wang, Q.
    Qin, J.
    He, B.
    Zhou, Y.
    Yang, J-J
    Hou, X. -L.
    Yang, X. -B.
    Chen, J. -H.
    Chen, Y. -D.
    CLINICAL RADIOLOGY, 2013, 68 (08) : 792 - 798