The Influence of Temporal Resolution in Determining Pharmacokinetic Parameters From DCE-MRI Data

被引:63
作者
Heisen, Marieke [1 ]
Fan, Xiaobing [2 ]
Buurman, Johannes [3 ]
van Riel, Natal A. W.
Karczmar, Gregory S. [2 ]
Romeny, Bart M. ter Haar
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, Sect Biomed Image Anal, NL-5600 MB Eindhoven, Netherlands
[2] Univ Chicago, Dept Radiol, Chicago, IL 60637 USA
[3] Philips Healthcare, Healthcare Informat, Best, Netherlands
关键词
DCE-MRI; temporal resolution; k-space data; pharmacokinetic model; downsampling; CONTRAST-ENHANCED MRI; T-1-WEIGHTED MRI; BREAST; TRACER; TUMORS;
D O I
10.1002/mrm.22171
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated the influence of the temporal resolution of dynamic contrast-enhanced MRI data on pharmacokinetic parameter estimation. Dynamic Gd-DTPA (Gadolinium-diethylene triamine pentaacetic acid) enhanced MRI data of implanted prostate tumors on rat hind limb were acquired at 4.7 T, with a temporal resolution of similar to 5 sec. The data were subsequently downsampled to temporal resolutions in the range of 15 sec to 85 sec, using a strategy that involves a recombination of k-space data. A basic two-compartment model was fit to the contrast agent uptake curves. The results demonstrated that as temporal resolution decreases, the volume transfer constant (K(trans)) is progressively underestimated (similar to 4% to similar to 25%), and the fractional extravascular extracellular space (v(e)) is progressively overestimated (similar to 1% to similar to 10%). The proposed downsampling strategy simulates the influence of temporal resolution more realistically than simply downsampling by removing samples. Magn Reson Med 63:811-816, 2010. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:811 / 816
页数:6
相关论文
共 22 条
[1]   System identification theory in pharmacokinetic modeling of dynamic contrast-enhanced MRI: Influence of contrast injection [J].
Aerts, H. J. W. L. ;
van Riel, N. A. W. ;
Backes, W. H. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) :1111-1119
[2]   Spatial and temporal resolution effects on dynamic contrast-enhanced magnetic resonance mammography [J].
Aref, Michael ;
Handbury, Josh D. ;
Ji, Jim Xiuquan ;
Aref, Susanne ;
Wiener, Erik C. .
MAGNETIC RESONANCE IMAGING, 2007, 25 (01) :14-34
[3]   Uncertainty in the analysis of tracer kinetics using dynamic contrast-enhanced T1-weighted MRI [J].
Buckley, DL .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :601-606
[4]   Investigation and optimization of parameter accuracy in dynamic contrast-enhanced MRI [J].
Cheng, Hai-Ling Margaret .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 28 (03) :736-743
[5]  
ELKHOULI R, 2008, ISMRM 16 SCI M, P3751
[6]   New model for analysis of dynamic contrast-enhanced MRI data distinguishes metastatic from nonmetastatic transplanted rodent prostate tumors [J].
Fan, XB ;
Medved, M ;
River, JN ;
Zamora, M ;
Corot, C ;
Robert, P ;
Bourrinet, P ;
Lipton, M ;
Culp, RM ;
Karczmar, GS .
MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (03) :487-494
[7]   Dynamic contrast-enhanced magnetic resonance imaging reveals stress-induced angiogenesis in MCF7 human breast tumors [J].
FurmanHaran, E ;
Margalit, R ;
Grobgeld, D ;
Degani, H .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1996, 93 (13) :6247-6251
[8]  
GAL Y, 2007, C P IEEE ENG MED BIO, P71
[9]  
Gibbons JD, 2014, Nonparametric statistical inference: Revised and expanded
[10]   Coomparative study of methods for determining vascular permeability and blood volume in human gliomas [J].
Harrer, JU ;
Parker, GJM ;
Haroon, HA ;
Buckley, DL ;
Embelton, K ;
Roberts, C ;
Balériaux, D ;
Jackson, A .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) :748-757