Automated blood component collection with the MCS 3p cell separator: evaluation of three protocols for buffy coat-poor and white cell-reduced packed red cells and plasma

被引:21
作者
Zeiler, TA
Kretschmer, V
机构
[1] Dept. Transfus. Med. Hemostaseology, Philipps University Clinics Marburg, Marburg
[2] Dept. Transfus. Med. Hemostaseology, Philipps University Clinics, D-35043, Marburg, Conradistrasse
[3] Dept. Transfus. Med. Hemostaseology, University Clinics, Philipps University
关键词
D O I
10.1046/j.1537-2995.1997.37897424400.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Automated collection of blood components with a cell separator (MCS 3p, Haemonetics), was performed according to three protocols. STUDY DESIGN AND METHODS:The first protocol provided 2 units of fresh-frozen plasma (FFP); and one buy, coat-poor red cell (RBC) concentrate in additive solution. The second protocol included an additional inline filtration of the RBC in a closed system after storage at 4 degrees C for 24 hours. In the third protocol, an additional platelet concentrate (PC) was recovered from the buffy coat. Cell counts and biochemical characterization of the RBCs (n = 20 each) were determined on Days 0, 1, 14, 28, and 49. RESULTS: The RBC volume was 336 +/- 9 mt (first protocol), 337 +/- 7 mt (second protocol) and 293 +/- 12 mt (third protocol) with a hematocrit of 59 +/- 2, 53 +/- 3, and 61 +/- 5, percent respectively. On Day 49, hemolysis was 0.24 +/- 0.1 percent (first protocol), 0.33 +/- 0.32 percent (second protocol), and 0.38 +/- 0.1 percent(third protocol). The filtered RBC concentrate met the international standards for white cell-reduced RBCs. Filtration resulted in a clinically irrelevant increase of hemolysis. The in vitro RBC values (lactate dehydrogenase, 2-hydroxybutyrate dehydrogenase, hemolysis, potassium, 2,3 DPG, ATP) were at least equal to those in RBCs collected by conventional whole-blood donation. There is a trend toward extended preservation of 2,3 DPG in RBCs collected by apheresis. Two units of FFP could be collected with each donation (first protocol: 420 +/- 55 mt, 5.4 +/- 7 WBCs/mu L, 6.5 +/- 5 x 10(3) platelets/mu L; second protocol: 440 +/- 33 mL, 3 +/- 5.2 WBCs/mu L, 32 +/- 12 x 10(3) platelets/mu L; third protocol: 398 +/- 32 mt, 5 +/- 12 WBCs/mu L; 3.4 +/- 3.5 x 10(3) platelets/mu L). PCs prepared from the buffy coat collected by the third protocol contained 90 +/- 30 x 10(9) platelets in 88 +/- 14 mt of plasma. In vitro test results in these PCs were superior to those in PCs collected by conventional whole-blood donation. The procedure was well tolerated by all donors. No adverse reactions appeared. CONCLUSION: Erythroplasmapheresis with the MCS 3p cell separator is a useful alternative to conventional whole-blood donation and separation.
引用
收藏
页码:791 / 797
页数:7
相关论文
共 26 条
  • [1] ANDREU G, 1988, BLOOD, V72, P946
  • [2] *BOARD SCI ADV BOA, GUID THER BLOOD COMP
  • [3] CAN (SHOULD) APHERESIS SUPPLANT WHOLE-BLOOD COLLECTION
    CIAVARELLA, D
    [J]. TRANSFUSION SCIENCE, 1992, 13 (02): : 201 - 205
  • [4] *COUC EUR, 1995, GUID PREP US QUAL AS
  • [5] DIETRICH G, 1992, INFUSIONSTHERAPIE, V19, P151
  • [6] EVALUATION OF TECHNETIUM-99M-CHROMIUM-51 POST-TRANSFUSION RECOVERY OF RED-CELLS STORED IN SALINE, ADENINE, GLUCOSE, MANNITOL FOR 42 DAYS
    HEATON, WAL
    KEEGAN, T
    HOLME, S
    MOMODA, G
    [J]. VOX SANGUINIS, 1989, 57 (01) : 37 - 42
  • [7] EFFECTS OF 3-5LOG(10) PRESTORAGE LEUKOCYTE DEPLETION ON RED-CELL STORAGE AND METABOLISM
    HEATON, WAL
    HOLME, S
    SMITH, K
    BRECHER, ME
    PINEDA, A
    AUBUCHON, JP
    NELSON, E
    [J]. BRITISH JOURNAL OF HAEMATOLOGY, 1994, 87 (02) : 363 - 368
  • [8] RED BLOOD-CELL PRESERVATION IN PROTEIN-POOR MEDIA .1. LEUKOCYTE ENZYMES AS A CAUSE OF HEMOLYSIS
    HOGMAN, CF
    HEDLUND, K
    AKERBLOM, O
    VENGE, P
    [J]. TRANSFUSION, 1978, 18 (02) : 233 - 241
  • [9] Holme S., 1995, Transfusion (Bethesda), V35, p8S
  • [10] IT SEEMED A PITY TO THROW AWAY THE RED-CELLS - SELECTIVE COMPONENT COLLECTION
    KLEIN, HG
    [J]. TRANSFUSION, 1993, 33 (10) : 788 - 790