Multi-Area Power System Reliability Evaluation by Application of Copula Theory

被引:0
作者
Tomasson, Egill [1 ]
Soder, Lennart [1 ]
机构
[1] KTH Royal Inst Technol, Elect Power Syst Dept, Stockholm, Sweden
来源
2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM) | 2016年
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Evaluating the risk of capacity deficit in large interconnected power systems is an important task in planning studies in order to supply the demand in the system at a certain risk level. It makes it possible to identify in which parts of the system reinforcements are needed in terms of generating capacity and/or interconnections. In modern power systems, with tie lines interconnecting countries and continents as well as an increasing amount of intermittent renewable resources, areas become dependent on each other for generating capacity not only under rare hazardous operating conditions but also in what can be considered as normal operation. This paper presents a novel way of taking inter-area load correlation into account when calculating the risk of capacity deficit by applying Copula sampling. The Monte Carlo simulation method is applied in addition to a Cross-Entropy based importance sampling technique to reduce computation time. The resulting procedure is a computationally effective general method of evaluating the risk of capacity deficit in a large scale multi-area interconnected power system.
引用
收藏
页数:5
相关论文
共 50 条
[41]   Application of flower pollination algorithm in load frequency control of multi-area interconnected power system with nonlinearity [J].
Jagatheesan, K. ;
Anand, B. ;
Samanta, Sourav ;
Dey, Nilanjan ;
Santhi, V. ;
Ashour, Amira S. ;
Balas, Valentina E. .
NEURAL COMPUTING & APPLICATIONS, 2017, 28 :S475-S488
[42]   A Novel Approach for Automatic Generation Control of a Multi-Area Power System [J].
Khuntia, Swasti R. ;
Panda, Sidhartha .
2011 24TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2011, :1182-1187
[43]   Optimization of stability criterion for multi-area power system with time delay [J].
Liu Y.-P. ;
Wang W.-D. ;
Mei P. ;
Zhang Y.-H. .
Kongzhi Lilun Yu Yingyong/Control Theory and Applications, 2018, 35 (07) :994-1001
[44]   Application of Self-Tuning FPIC to AGC for Load Frequency Control in Multi-Area Power System [J].
Sheikh, M. R. I. ;
Muyeen, S. M. ;
Takahashi, Rion ;
Murata, Toshiaki ;
Tamura, Junji .
2009 IEEE BUCHAREST POWERTECH, VOLS 1-5, 2009, :1211-1217
[45]   Multi-area multi-source automatic generation control in deregulated power system [J].
Ghasemi-Marzbali, Ali .
ENERGY, 2020, 201
[46]   Application of NARMA L2 controller for Load frequency control of multi-area power system [J].
Nath, V. ;
Sambariya, D. K. .
PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND CONTROL (ISCO'16), 2016,
[47]   Decentralized load frequency controller for a multi-area interconnected power system [J].
Alrifai, Muthana T. ;
Hassan, Mohamed F. ;
Zribi, Mohamed .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2011, 33 (02) :198-209
[48]   DECENTRALIZED CONTROL OF MULTI-AREA POWER SYSTEM RESTRUCTURING FOR LFC OPTIMIZATION [J].
Thirukkovulur, Ateeth Kumar ;
Nandagopal, Harikrishna ;
Parivallal, Vigneesh .
2012 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH (ICCIC), 2012, :169-174
[49]   Multi-Area Generation Adequacy and Capacity Credit in Power System Analysis [J].
Tomasson, Egill ;
Soder, Lennart .
2017 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT-ASIA), 2017, :194-199
[50]   Decentralized adaptive load frequency control in a multi-area power system [J].
Menniti, D ;
Pinnarelli, A ;
Scordino, N ;
Sorrentino, N .
LARGE SCALE SYSTEMS: THEORY AND APPLICATIONS 2001 (LSS'01), 2001, :157-163