Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies

被引:8
作者
Petibon, Yoann [1 ,2 ]
Rakvongthai, Yothin [3 ]
El Fakhri, Georges [1 ,2 ]
Ouyang, Jinsong [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Gordon Ctr Med Imaging, Boston, MA USA
[2] Harvard Med Sch, Dept Radiol, Boston, MA USA
[3] Chulalongkorn Univ, Div Nucl Med, Dept Radiol, Fac Med, Bangkok, Thailand
关键词
direct parametric reconstruction; dynamic PET; myocardial perfusion imaging; kinetic modeling; parametric imaging; preconditioned conjugate gradient; POSITRON-EMISSION-TOMOGRAPHY; BLOOD-FLOW; IMAGES; MR; 3D; QUANTIFICATION; ALGORITHMS; CARDIOLOGY; HEART; MODEL;
D O I
10.1088/1361-6560/aa6394
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of similar to 7-8 mCi of F-18-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering similar to 5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans-each containing 1/8th of the total number of events-were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of F-18-flurpiridaz. An imagederived arterial input function obtained from a TAC taken in the left ventriclecavity was used for tracer kinetic analysis. For the indirect method, frame-byframe images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted leastsquare fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori ( MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed preconditioner. The performance of the direct method was evaluated by comparing voxel-and segment-wise estimates of K1, the tracer transport rate (ml min(-1) ml(-1)), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced K-1 maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSLMAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced K-1 estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance.
引用
收藏
页码:3539 / 3565
页数:27
相关论文
共 60 条
[1]   Single-scan rest/stress imaging 18F-labeled flow tracers [J].
Alpert, Nathaniel ;
Fang, Yu-Hua Dean ;
El Fakhri, Georges .
MEDICAL PHYSICS, 2012, 39 (11) :6609-6620
[2]  
[Anonymous], 1999, Athena scientific Belmont
[3]   IMPROVED ASSESSMENT OF CAD IN OBESE SUBJECTS WITH FLURPIRIDAZ F18 PET MYOCARDIAL PERFUSION IMAGING: A SUBSET ANALYSIS OF THE FLURPIRIDAZ F18 301 PHASE 3 STUDY [J].
Bateman, Timothy M. ;
Maddahi, Jamshid ;
Udelson, James ;
Beanlands, Rob ;
Knuuti, Juhani ;
Heller, Gary ;
Berman, Daniel ;
Lazewatsky, Joel ;
Orlandi, Cesare .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) :1578-1578
[4]   Implementation and evaluation of a 3D one-step late reconstruction algorithm for 3D positron emission tomography brain studies using median root prior [J].
Bettinardi, V ;
Pagani, E ;
Gilardi, MC ;
Alenius, S ;
Thielemans, K ;
Teras, M ;
Fazio, F .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2002, 29 (01) :7-18
[5]  
Boellaard R, 2001, J NUCL MED, V42, P808
[6]   A STATISTICAL-MODEL FOR POSITRON EMISSION TOMOGRAPHY - THE EM PARAMETRIC IMAGE-RECONSTRUCTION ALGORITHM - COMMENT [J].
CARSON, RE ;
LANGE, K .
JOURNAL OF THE AMERICAN STATISTICAL ASSOCIATION, 1985, 80 (389) :20-22
[7]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart: A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
JOURNAL OF NUCLEAR CARDIOLOGY, 2002, 9 (02) :240-245
[8]   A Scatter Calibration Technique for Dynamic Brain Imaging in High Resolution PET [J].
Cheng, Ju-Chieh ;
Blinder, Stephan ;
Rahmim, Arman ;
Sossi, Vesna .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) :225-233
[9]   A mass conservation-based optical flow method for cardiac motion correction in 3D-PET [J].
Dawood, Mohammad ;
Gigengack, Fabian ;
Jiang, Xiaoyi ;
Schaefers, Klaus P. .
MEDICAL PHYSICS, 2013, 40 (01)
[10]   Will 3-dimensional PET-CT enable the routine quantification of myocardial blood flow? [J].
dekemp, Robert A. ;
Yoshinaga, Keiichiro ;
Beanlands, Rob S. B. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2007, 14 (03) :380-397