Biomechanical response of lumbar facet joints under follower preload: a finite element study

被引:60
作者
Du, Cheng-Fei [1 ,2 ]
Yang, Nan [1 ]
Guo, Jun-Chao [2 ]
Huang, Yun-Peng [3 ]
Zhang, Chunqiu [1 ]
机构
[1] Tianjin Univ Technol, Tianjin Key Lab Adv Mechatron Syst Design & Intel, 391 Binshui West Rd, Tianjin 300384, Peoples R China
[2] Beihang Univ, Sch Biol Sci & Med Engn, Key Lab Biomech & Mechanobiol, Minist Educ, Beijing 100191, Peoples R China
[3] Fujian Med Univ, Affiliated Hosp 1, Dept Orthopaed, Fuzhou 350005, Peoples R China
来源
BMC MUSCULOSKELETAL DISORDERS | 2016年 / 17卷
基金
中国国家自然科学基金;
关键词
Facet joint; Follower load; Biomechanics; Lumbar spine; Finite element; MOTION SEGMENT; CALIBRATION METHOD; CONTACT FORCES; LOADING RATE; SPINE; COMPRESSION; EXTENSION; FLEXION; MODEL;
D O I
10.1186/s12891-016-0980-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Facet joints play a significant role in providing stability to the spine and they have been associated with low back pain symptoms and other spinal disorders. The influence of a follower load on biomechanics of facet joints is unknown. A comprehensive research on the biomechanical role of facets may provide insight into facet joint instability and degeneration. Method: A nonlinear finite element (FE) model of lumbar spine (L1-S1) was developed and validated to study the biomechanical response of facets, with different values of follower preload (0 N, 500 N, 800 N, 1200 N), under loadings in the three anatomic planes. In this model, special attention was paid to the modeling of facet joints, including cartilage layer. The asymmetry in the biomechanical response of facets was also discussed. A rate of change (ROC) and an average asymmetry factor (AAF) were introduced to explore and evaluate the preload effect on these facet contact parameters and on the asymmetry under different loading conditions. Results: The biomechanical response of facets changed according to the loading condition. The preload amplified the facet force, contact area and contact pressure in flexion-extension; the same effect was observed on the ipsilateral facet while an opposite effect could be seen on the contralateral facet during lateral bending. For torsion loading, the preload increased contact area, decreased the mean contact pressure, but had almost no effect on facet force. However, all the effects of follower load on facet response became weaker with the increase of preload. The greatest asymmetry of facet response could be found on the ipsilateral side during lateral bending, followed by flexion, bending (contralateral side), extension and torsion. This asymmetry could be amplified by preload in the bending (ipsilateral), torsion loading group, while being reduced in the flexion group. Conclusions: An analysis combining patterns of contact pressure distribution, facet load, contact area and contact pressure can provide more insight into the biomechanical role of facets under various moment loadings and follower loads. The effect of asymmetry on facet joint response should be fully considered in biomechanical studies of lumbar spine, especially in post structures subjected to physiological loadings.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Comparison of the biomechanical effects of lumbar disc degeneration on normal patients and osteoporotic patients: A finite element analysis
    Zhang, Xin-Ying
    Han, Ye
    MEDICAL ENGINEERING & PHYSICS, 2023, 112
  • [42] Analyzing isolated degeneration of lumbar facet joints: implications for degenerative instability and lumbar biomechanics using finite element analysis
    Park, Jun Sung
    Goh, Tae Sik
    Lee, Jung Sub
    Lee, Chiseung
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [43] Biomechanical Effect of Constraint in Lumbar Total Disc Replacement A Study With Finite Element Analysis
    Chung, Sang Ki
    Kim, Young Eun
    Wang, Kyu-Chang
    SPINE, 2009, 34 (12) : 1281 - 1286
  • [44] Biomechanical modelling of indirect decompression in oblique lumbar intervertebral fusions - A finite element study
    Chayer, Mathieu
    Phan, Philippe
    Arnoux, Pierre-Jean
    Wang, Zhi
    Aubin, Carl-Eric
    CLINICAL BIOMECHANICS, 2024, 120
  • [45] Biomechanical study of oblique lumbar interbody fusion (OLIF) augmented with different types of instrumentation: a finite element analysis
    Cai, Xin-Yi
    Bian, Han-Ming
    Chen, Chao
    Ma, Xin-Long
    Yang, Qiang
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [46] Biomechanical analysis of lumbar decompression surgery in relation to degenerative changes in the lumbar spine - Validated finite element analysis
    Li, Quan You
    Kim, Ho-Joong
    Son, Juhyun
    Kang, Kyoung-Tak
    Chang, Bong-Soon
    Lee, Choon-Ki
    Seok, Hyun Sik
    Yeom, Jin S.
    COMPUTERS IN BIOLOGY AND MEDICINE, 2017, 89 : 512 - 519
  • [47] Biomechanical study of temporomandibular joints of patients with temporomandibular disorders under incisal clenching: A finite element analysis
    Yang, Chunxin
    Teng, Haidong
    Shao, Bingmei
    Liu, Zhan
    JOURNAL OF BIOMECHANICS, 2024, 166
  • [48] Comparative Biomechanical Analysis of Anterior Lumbar Interbody Fusion and Bilateral Expandable Transforaminal Lumbar Interbody Fusion Cages: A Finite Element Analysis Study
    Bakhaidar, Mohamad
    Harinathan, Balaji
    Devaraj, Karthik Banurekha
    DeGroot, Andrew
    Yoganandan, Narayan
    Shabani, Saman
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2024, 18 (04) : 441 - 447
  • [49] Biomechanical characterization of three iliac screw fixation techniques: A finite element study
    Sohn, Seil
    Park, Tae Hyun
    Chung, Chun Kee
    Kim, Yongjung Jay
    Jang, Jong Wuk
    Han, In-bo
    Lee, Sung Jae
    JOURNAL OF CLINICAL NEUROSCIENCE, 2018, 52 : 109 - 114
  • [50] Combined effect of artificial cervical disc replacement and facet tropism on the index-level facet joints: a finite element study
    Li, Jing
    Deng, Yuxiao
    Zhang, Junqi
    Wang, Beiyu
    Huang, Kangkang
    Liu, Hao
    Rong, Xin
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)