Signal-to-Noise Contribution of Principal Component Loads in Reconstructed Near-Infrared Raman Tissue Spectra

被引:13
|
作者
Grimbergen, M. C. M. [1 ,2 ]
van Swol, C. F. P. [3 ]
Kendall, C. [4 ]
Verdaasdonk, R. M. [2 ]
Stone, N. [4 ]
Bosch, J. L. H. R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Urol, Utrecht, Netherlands
[2] Univ Med Ctr, Dept Med Technol & Clin Phys, Utrecht, Netherlands
[3] St Antonius Hosp, Dept Med Phys, Nieuwegein, Netherlands
[4] Gloucestershire Hosp NHS Fdn Trust, Biophoton Res Unit, Gloucester, England
关键词
Signal-to-noise ratio; SNR; Principal component analysis; PCA; Raman spectroscopy; Bladder; IN-VIVO; SPECTROSCOPY; DIAGNOSIS; CANCER;
D O I
10.1366/000370210790572052
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The overall quality of Raman spectra in the near-infrared region, where biological samples are often studied, has benefited from various improvements to optical instrumentation over the past decade. However, obtaining ample spectral quality for analysis is still challenging due to device requirements and short integration times required for (in vivo) clinical applications of Raman spectroscopy. Multivariate analytical methods, such as principal component analysis (PCA) and linear discriminant analysis (LDA), are routinely applied to Raman spectral datasets to develop classification models. Data compression is necessary prior to discriminant analysis to prevent or decrease the degree of over-fitting. The logical threshold for the selection of principal components (PCs) to be used in discriminant analysis is likely to be at a point before the PCs begin to introduce equivalent signal and noise and, hence, include no additional value. Assessment of the signal-to-noise ratio (SNR) at a certain peak or over a specific spectral region will depend on the sample measured. Therefore, the mean SNR over the whole spectral region (SNRmsr) is determined in the original spectrum as well as for spectra reconstructed from an increasing number of principal components. This paper introduces a method of assessing the influence of signal and noise from individual PC loads and indicates a method of selection of PCs for LDA. To evaluate this method, two data sets with different SNRs were used. The sets were obtained with the same Raman system and the same measurement parameters on bladder tissue collected during white light cystoscopy (set A) and fluorescence-guided cystoscopy (set B). This method shows that the mean SNR over the spectral range in the original Raman spectra of these two data sets is related to the signal and noise contribution of principal component loads. The difference in mean SNR over the spectral range can also be appreciated since fewer principal components can reliably be used in the low SNR data set (set B) compared to the high SNR data set (set A). Despite the fact that no definitive threshold could be found, this method may help to determine the cutoff for the number of principal components used in discriminant analysis. Future analysis of a selection of spectral databases using this technique will allow optimum thresholds to be selected for different applications and spectral data quality levels.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [32] RAPID NEAR-INFRARED RAMAN-SPECTROSCOPY OF HUMAN TISSUE WITH A SPECTROGRAPH AND CCD DETECTOR
    BARAGA, JJ
    FELD, MS
    RAVA, RP
    APPLIED SPECTROSCOPY, 1992, 46 (02) : 187 - 190
  • [33] Spectroscopic characterization of human immunodeficiency virus type-1-infected plasma by principal component analysis and soft independent modeling of class analogy of visible and near-infrared spectra
    Bahmani, Mirza Khalil
    Khosravi, Ayyoob
    Miri, Ramin
    Iwabu, Yukie
    Ikuta, Kazuyoshi
    Sakudo, Akikazu
    MOLECULAR MEDICINE REPORTS, 2009, 2 (05) : 805 - 809
  • [34] Comparison of principal and independent component analysis in removing extracerebral interference from near-infrared spectroscopy signals
    Virtanen, Jaakko
    Noponen, Tommi
    Merilainen, Pekka
    JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (05)
  • [35] Discriminant analysis of Chinese patent medicines based on near-infrared spectroscopy and principal component discriminant transformation
    Xu, Zhihong
    Liu, Yan
    Li, Xiaoyong
    Cai, Wensheng
    Shao, Xueguang
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 149 : 985 - 990
  • [36] Near-infrared Raman spectra of terrestrial minerals: relevance for the remote analysis of Martian spectral signatures
    Villar, SEJ
    Edwards, HGM
    VIBRATIONAL SPECTROSCOPY, 2005, 39 (01) : 88 - 94
  • [37] Comparison of multivariate calibration models for glucose, urea, and lactate from near-infrared and Raman spectra
    Ren, Min
    Arnold, Mark A.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (03) : 879 - 888
  • [38] Deep learning-based ultra-fast identification of Raman spectra with low signal-to-noise ratio
    Liu, Kunxiang
    Chen, Fuyuan
    Shang, Lindong
    Wang, Yuntong
    Peng, Hao
    Liu, Bo
    Li, Bei
    JOURNAL OF BIOPHOTONICS, 2024, 17 (01)
  • [39] Fuzzy C-means clustering and principal component analysis of time series from near-infrared imaging of forearm ischemia
    Mansfield, JR
    Sowa, MG
    Scarth, GB
    Somorjai, RL
    Mantsch, HH
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1997, 21 (05) : 299 - 308
  • [40] Comparison of multivariate calibration models for glucose, urea, and lactate from near-infrared and Raman spectra
    Min Ren
    Mark A. Arnold
    Analytical and Bioanalytical Chemistry, 2007, 387 : 879 - 888