Signal-to-Noise Contribution of Principal Component Loads in Reconstructed Near-Infrared Raman Tissue Spectra

被引:13
|
作者
Grimbergen, M. C. M. [1 ,2 ]
van Swol, C. F. P. [3 ]
Kendall, C. [4 ]
Verdaasdonk, R. M. [2 ]
Stone, N. [4 ]
Bosch, J. L. H. R. [1 ]
机构
[1] Univ Med Ctr Utrecht, Dept Urol, Utrecht, Netherlands
[2] Univ Med Ctr, Dept Med Technol & Clin Phys, Utrecht, Netherlands
[3] St Antonius Hosp, Dept Med Phys, Nieuwegein, Netherlands
[4] Gloucestershire Hosp NHS Fdn Trust, Biophoton Res Unit, Gloucester, England
关键词
Signal-to-noise ratio; SNR; Principal component analysis; PCA; Raman spectroscopy; Bladder; IN-VIVO; SPECTROSCOPY; DIAGNOSIS; CANCER;
D O I
10.1366/000370210790572052
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The overall quality of Raman spectra in the near-infrared region, where biological samples are often studied, has benefited from various improvements to optical instrumentation over the past decade. However, obtaining ample spectral quality for analysis is still challenging due to device requirements and short integration times required for (in vivo) clinical applications of Raman spectroscopy. Multivariate analytical methods, such as principal component analysis (PCA) and linear discriminant analysis (LDA), are routinely applied to Raman spectral datasets to develop classification models. Data compression is necessary prior to discriminant analysis to prevent or decrease the degree of over-fitting. The logical threshold for the selection of principal components (PCs) to be used in discriminant analysis is likely to be at a point before the PCs begin to introduce equivalent signal and noise and, hence, include no additional value. Assessment of the signal-to-noise ratio (SNR) at a certain peak or over a specific spectral region will depend on the sample measured. Therefore, the mean SNR over the whole spectral region (SNRmsr) is determined in the original spectrum as well as for spectra reconstructed from an increasing number of principal components. This paper introduces a method of assessing the influence of signal and noise from individual PC loads and indicates a method of selection of PCs for LDA. To evaluate this method, two data sets with different SNRs were used. The sets were obtained with the same Raman system and the same measurement parameters on bladder tissue collected during white light cystoscopy (set A) and fluorescence-guided cystoscopy (set B). This method shows that the mean SNR over the spectral range in the original Raman spectra of these two data sets is related to the signal and noise contribution of principal component loads. The difference in mean SNR over the spectral range can also be appreciated since fewer principal components can reliably be used in the low SNR data set (set B) compared to the high SNR data set (set A). Despite the fact that no definitive threshold could be found, this method may help to determine the cutoff for the number of principal components used in discriminant analysis. Future analysis of a selection of spectral databases using this technique will allow optimum thresholds to be selected for different applications and spectral data quality levels.
引用
收藏
页码:8 / 14
页数:7
相关论文
共 50 条
  • [1] Method for leveling the signal-to-noise ratio in multichannel functional near-infrared spectroscopy
    Yamada, Toru
    Umeyama, Shinji
    Kamoshida, Atsushi
    NEURAL IMAGING AND SENSING, 2017, 10051
  • [2] Extrapolation of Type Ia Supernova Spectra into the Near-infrared Using Principal Component Analysis
    Burrow, Anthony
    Baron, E.
    Burns, Christopher R.
    Hsiao, Eric Y.
    Lu, Jing
    Ashall, Chris
    Brown, Peter J.
    DerKacy, James M.
    Folatelli, G.
    Galbany, Lluis
    Hoeflich, P.
    Krisciunas, Kevin
    Morrell, N.
    Phillips, M. M.
    Shappee, Benjamin J.
    Stritzinger, Maximilian D.
    Suntzeff, Nicholas B.
    ASTROPHYSICAL JOURNAL, 2024, 967 (01)
  • [3] Recovery of Raman spectra with low signal-to-noise ratio using Wiener estimation
    Chen, Shuo
    Lin, Xiaoqian
    Yuen, Clement
    Padmanabhan, Saraswathi
    Beuerman, Roger W.
    Liu, Quan
    OPTICS EXPRESS, 2014, 22 (10): : 12102 - 12114
  • [4] Relationship between wavelength combination and signal-to-noise ratio in measuring hemoglobin concentrations using visible or near-infrared light
    Funane, Tsukasa
    Atsumori, Hirokazu
    Sato, Hiroki
    Kiguchi, Masashi
    Maki, Atsushi
    OPTICAL REVIEW, 2009, 16 (04) : 442 - 448
  • [5] In-Line Near-Infrared (NIR) and Raman Spectroscopy Coupled with Principal Component Analysis (PCA) for In Situ Evaluation of the Transesterification Reaction
    Fontalvo-Gomez, Miriam
    Colucci, Jose A.
    Velez, Natasha
    Romanach, Rodolfo J.
    APPLIED SPECTROSCOPY, 2013, 67 (10) : 1142 - 1149
  • [6] Reaction Monitoring by Means of Multivariate Data Analysis of Near-Infrared and Raman Spectra
    Hetemi, Dardan
    Janagap, Steve
    ACTA CHIMICA SLOVENICA, 2017, 64 (04) : 818 - 824
  • [7] Characterization of Automobile Plastics by Principal Component Analysis and Near-Infrared Spectroscopy
    Zhao, Qinghua
    Chen, Ming
    ANALYTICAL LETTERS, 2015, 48 (02) : 301 - 307
  • [8] Near-infrared Raman spectrometer systems for human tissue studies
    Brennan, JF
    Wang, Y
    Dasari, RR
    Feld, MS
    APPLIED SPECTROSCOPY, 1997, 51 (02) : 201 - 208
  • [9] An automatic method for accurate signal-to-noise ratio estimation and baseline correction of Raman spectra of environmental microplastics
    Yang, Zijiang
    Nagashima, Hiroya
    Murat, Celik
    Arakawa, Hisayuki
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2025, 325
  • [10] Relationship between wavelength combination and signal-to-noise ratio in measuring hemoglobin concentrations using visible or near-infrared light
    Tsukasa Funane
    Hirokazu Atsumori
    Hiroki Sato
    Masashi Kiguchi
    Atsushi Maki
    Optical Review, 2009, 16 : 442 - 448