Evaluation of indirect blood pressure monitoring in awake and anesthetized red-tailed hawks (Buteo jamaicensis): effects of cuff size, cuff placement, and monitoring equipment

被引:23
作者
Zehnder, Ashley M. [2 ]
Hawkins, Michelle G. [1 ]
Pascoe, Peter J. [3 ]
Kass, Philip H. [4 ]
机构
[1] Univ Calif Davis, Sch Vet Med, Dept Med & Epidemiol, Davis, CA 95616 USA
[2] Univ Calif Davis, Sch Vet Med, Vet Med Teaching Hosp, Davis, CA 95616 USA
[3] Univ Calif Davis, Sch Vet Med, Dept Surg & Radiol Sci, Davis, CA 95616 USA
[4] Univ Calif Davis, Sch Vet Med, Dept Populat Hlth & Reprod, Davis, CA 95616 USA
关键词
avian; bird; Doppler; indirect blood pressure; norepinephrine; oscillometric; red-tailed hawk; sphygmomanometer; CARDIOPULMONARY DOSE-RESPONSE; HISPANIOLAN AMAZON PARROTS; CONTROLLED VENTILATION; ISOFLURANE; DOGS; ACCURACY; SEVOFLURANE; ANESTHESIA; AGREEMENT; DUCKS;
D O I
10.1111/j.1467-2995.2009.00485.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Objective To compare Doppler and oscillometric methods of indirect arterial blood pressure (IBP) with direct arterial measurements in anesthetized and awake red-tailed hawks. Study design Prospective, randomized, blinded study. Animals Six, sex unknown, adult red-tailed hawks. Methods Birds were anesthetized and IBP measurements were obtained by oscillometry (IBP-O) and Doppler (IBP-D) on the pectoral and pelvic limbs using three cuffs of different width based on limb circumference: cuff 1 (20-30% of circumference), cuff 2 (30-40%), and cuff 3 (40-50%). Direct arterial pressure measurements were obtained from the contralateral superficial ulnar artery. Indirect blood pressure measurements were compared to direct systolic arterial pressure (SAP) and mean arterial pressure (MAP) during normotension and induced states of hypotension and hypertension. Measurements were also obtained in awake, restrained birds. Three-way anova, linear regression and Bland-Altman analyses were used to evaluate the IBP-D data. Results are reported as mean bias (95% confidence intervals). Results The IBP-O monitor reported errors during 54% of the measurements. Indirect blood pressure Doppler measurements were most accurate with cuff 3 and were comparable to MAP with a bias of 2 (-9, 13 mmHg). However, this cuff consistently underestimated SAP with a bias of 33 (19, 48 mmHg). Variability in the readings within and among birds was high. There was no significant difference between sites of cuff placement. Awake birds had SAP, MAP and diastolic arterial pressure that were 56, 43, and 38 mmHg higher than anesthetized birds. Conclusions and clinical relevance Indirect blood pressure (oscillometric) measurements were unreliable in red-tailed hawks. Indirect blood pressure (Doppler) measurements were closer to MAP measurements than SAP measurements. There was slightly better agreement with the use of cuff 3 on either the pectoral or pelvic limbs. Awake, restrained birds have significantly higher arterial pressures than those under sevoflurane anesthesia.
引用
收藏
页码:464 / 479
页数:16
相关论文
共 38 条
  • [1] Agreement between direct and indirect blood pressure measurements obtained from anesthetized Hispaniolan Amazon parrots
    Acierno, Mark J.
    da Cunha, Anderson
    Smith, Julie
    Tully, Thomas N., Jr.
    Guzman, David Sanchez-Migallon
    Serra, Verna
    Mitchell, Mark A.
    [J]. JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2008, 233 (10): : 1587 - 1590
  • [2] ADAMS HR, 2001, VET PHARM THERAPEUTI, P184
  • [3] DOPPLER ULTRASONOGRAPHIC, OSCILLOMETRIC SPHYGMOMANOMETRIC, AND PHOTOPLETHYSMOGRAPHIC TECHNIQUES FOR NONINVASIVE BLOOD-PRESSURE MEASUREMENT IN ANESTHETIZED CATS
    BINNS, SH
    SISSON, DD
    BUOSCIO, DA
    SCHAEFFER, DJ
    [J]. JOURNAL OF VETERINARY INTERNAL MEDICINE, 1995, 9 (06) : 405 - 414
  • [4] Applying the right statistics: analyses of measurement studies
    Bland, JM
    Altman, DG
    [J]. ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2003, 22 (01) : 85 - 93
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Evaluation of an oscillometric blood pressure monitor on anesthetized cats and the effect of cuff placement and fur on accuracy
    Branson, KR
    WagnerMann, CC
    Mann, FA
    [J]. VETERINARY SURGERY, 1997, 26 (04) : 347 - 353
  • [7] BRUNER JMR, 1981, MED INSTRUM, V15, P11
  • [8] VALIDATION IN AWAKE RATS OF A TAIL-CUFF METHOD FOR MEASURING SYSTOLIC PRESSURE
    BUNAG, RD
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1973, 34 (02) : 279 - 282
  • [9] WALL STRUCTURE OF LARGE ARTERIES IN BIRDS - INVESTIGATIONS BY LIGHT-MICROSCOPY AND ELECTRON-MICROSCOPY
    BUSSOW, H
    [J]. ZEITSCHRIFT FUR ZELLFORSCHUNG UND MIKROSKOPISCHE ANATOMIE, 1973, 142 (02): : 263 - 288
  • [10] *CAS MED SYST INC, 2004, SHARN VET, V1, P72