Interfraction variation and dosimetric changes during image-guided radiation therapy in prostate cancer patients

被引:19
作者
Fuchs, Frederik [1 ]
Habl, Gregor [1 ]
Devecka, Michal [1 ]
Kampfer, Severin [1 ]
Combs, Stephanie E. [1 ,2 ]
Kessel, Kerstin A. [1 ,2 ]
机构
[1] Tech Univ Munich, Dept Radiat Oncol, Ismaninger Str 22, D-81675 Munich, Germany
[2] Helmholtz Zentrum Munchen, Dept Radiat Sci, Inst Radiat Med, Neuherberg, Germany
来源
RADIATION ONCOLOGY JOURNAL | 2019年 / 37卷 / 02期
关键词
Prostatic neoplasms; Image-guided radiotherapy; Intensity-modulated radiotherapy; Urinary bladder; Rectum; DOSE-VOLUME HISTOGRAMS; ENDORECTAL BALLOONS; BLADDER; MOTION; RADIOTHERAPY; STABILITY; RECTUM; IMPACT;
D O I
10.3857/roj.2018.00514
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The aim of this study was to identify volume changes and dose variations of rectum and bladder during radiation therapy in prostate cancer (PC) patients. Materials and Methods: We analyzed 20 patients with PC treated with helical tomotherapy. Daily image guidance was performed. We re-contoured the entire bladder and rectum including its contents as well as the organ walls on megavoltage computed tomography once a week. Dose variations were analyzed by means of Dmedian, Dmean, Dmax, V-10 to V-75, as well as the organs at risk (OAR) volume. Further, we investigated the correlation between volume changes and changes in Dmean of OAR. Results: During treatment, the rectal volume ranged from 62% to 223% of its initial volume, the bladder volume from 22% to 375%. The average Dmean ranged from 87% to 118% for the rectum and 58% to 160% for the bladder. The Pearson correlation coefficients between volume changes and corresponding changes in Dmean were -0.82 for the bladder and 0.52 for the rectum. The comparison of the dose wall histogram (DWH) and the dose volume histogram (DVH) showed that the DVH underestimates the percentage of the rectal and bladder volume exposed to the high dose region. Conclusion: Relevant variations in the volume of OAR and corresponding dose variations can be observed. For the bladder, an increase in the volume generally leads to lower doses; for the rectum, the correlation is weaker. Having demonstrated remarkable differences in the dose distribution of the DWH and the DVH, the use of DWHs should be considered.
引用
收藏
页码:127 / 133
页数:7
相关论文
共 20 条
  • [1] Correlation between surrogates of bladder dosimetry and dose-volume histograms of the bladder wall defined on MRI in prostate cancer radiotherapy
    Carillo, Viviana
    Cozzarini, Cesare
    Chietera, Andreina
    Perna, Lucia
    Gianolini, Stefano
    Maggio, Angelo
    Botti, Andrea
    Rancati, Tiziana
    Valdagni, Riccardo
    Fiorino, Claudio
    [J]. RADIOTHERAPY AND ONCOLOGY, 2012, 105 (02) : 180 - 183
  • [2] Rectal dose variation during the course of image-guided radiation therapy of prostate cancer
    Chen, Lili
    Paskalev, Kamen
    Xu, Xiu
    Zhu, Jennifer
    Wang, Lu
    Price, Robert A.
    Hu, Wei
    Feigenberg, Steven J.
    Horwitz, Eric M.
    Pollack, Alan
    Ma, C. M. Charlie
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 95 (02) : 198 - 202
  • [3] Dosimetric impact of different bladder and rectum filling during prostate cancer radiotherapy
    Chen, Zhi
    Yang, Zhaozhi
    Wang, Jiazhou
    Hu, Weigang
    [J]. RADIATION ONCOLOGY, 2016, 11
  • [4] Superior target volume and organ stability with the use of endorectal balloons in post-prostatectomy radiotherapy
    de Leon, Jeremiah F.
    Jameson, Michael G.
    Windsor, Apsara
    Cloak, Kirrily
    Keats, Sarah
    Vial, Philip
    Holloway, Lois
    Metcalfe, Peter
    Sidhom, Mark
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2015, 59 (04) : 507 - 513
  • [5] Distinct effects of rectum delineation methods in 3D-confromal vs. IMRT treatment planning of prostate cancer
    Guckenberger, Matthias
    Meyer, Juergen
    Baier, Kurt
    Vordermark, Dirk
    Flentje, Michael
    [J]. RADIATION ONCOLOGY, 2006, 1 (1)
  • [6] Intrafraction prostate motion during IMRT for prostate cancer
    Huang, E
    Dong, L
    Chandra, A
    Kuban, DA
    Rosen, II
    Evans, A
    Pollack, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (02): : 261 - 268
  • [7] Fractionated changes in prostate cancer radiotherapy using cone-beam computed tomography
    Huang, Tzung-Chi
    Chou, Kuei-Ting
    Yang, Shih-Neng
    Chang, Chih-Kai
    Liang, Ji-An
    Zhang, Geoffrey
    [J]. MEDICAL DOSIMETRY, 2015, 40 (03) : 222 - 225
  • [8] Endorectal balloons in the post prostatectomy setting: Do gains in stability lead to more predictable dosimetry?
    Jameson, Michael G.
    De Leon, Jeremiah
    Windsor, Apsara A.
    Cloak, Kirrily
    Keats, Sarah
    Dowling, Jason A.
    Chandra, Shekhar S.
    Vial, Philip
    Sidhom, Mark
    Holloway, Lois
    Metcalfe, Peter
    [J]. RADIOTHERAPY AND ONCOLOGY, 2013, 109 (03) : 493 - 497
  • [9] Daily variations in delivered doses in patients treated with radiotherapy for localized prostate cancer
    Kupelian, Patrick A.
    Langen, Katja M.
    Zeidan, Omar A.
    Meeks, Sanford L.
    Willoughby, Twyla R.
    Wagner, Thomas H.
    Jeswani, Sam
    Ruchala, Kenneth J.
    Haimerl, Jason
    Olivera, Gustavo H.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : 876 - 882
  • [10] Organ motion and its management
    Langen, KM
    Jones, DTL
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 50 (01): : 265 - 278