Wind effects on smoke motion and temperature of ventilation-control led fire in a two-vent compartment

被引:44
作者
Chen, Haixiang [1 ]
Liu, Naian [1 ]
Chow, Wanki [2 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230027, Anhui, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
关键词
Compartment fire; Wind; Smoke; Post-flashover; MULTIPLE STEADY-STATES; NATURAL VENTILATION; COMBINED BUOYANCY; REFUGE FLOOR; ENCLOSURE; RATES;
D O I
10.1016/j.buildenv.2009.04.008
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
High-rise building fire is often influenced by the ambient wind. Study concerning fire behavior in the compartment of high-rise buildings in wind environment is needed for exploring some effective methods used for evaluation of compartment fire smoke movement and control. In this paper, smoke flowing direction and temperature of ventilation-control led fire in a two-vent compartment are studied when ambient wind blows to the vent at higher altitude. It is found that there is a critical wind speed, above which the direction of smoke movement is dominated by wind rather than by buoyancy. It is also found that ambient wind has a complex influence on smoke temperature in the compartment. When wind speed exceeds another critical value, only one steady state appears in the smoke temperature rising curve. Otherwise three steady states appear. Heat transfer through the compartment walls has great influence on the second critical wind speed. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2521 / 2526
页数:6
相关论文
共 21 条
[1]   Airflow rates by combined natural ventilation with opposing wind-unambiguous solutions for practical use [J].
Andersen, Karl Terpager .
BUILDING AND ENVIRONMENT, 2007, 42 (02) :534-542
[2]  
[Anonymous], 2004, CODE PRACTICE WIND E
[3]  
CHEN H, 2008, FIR SAF SCI P 9 INT, P907
[4]   Effects of building wall arrangements on wind-induced ventilation through the refuge floor of a tall building [J].
Cheng, C. C. K. ;
Lam, K. M. ;
Demirbilek, F. N. .
JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2008, 96 (05) :656-664
[5]   A study of natural ventilation in a refuge floor [J].
Cheng, Charles C. K. ;
Lam, K. M. ;
Yuen, Richard K. K. ;
Lo, S. M. ;
Liang, J. .
BUILDING AND ENVIRONMENT, 2007, 42 (09) :3322-3332
[6]  
CHOW WKJ, 2004, ASHRAE 2004 ANN M, P1
[7]   Mass pyrolysis rates and excess pyrolysate in fully developed enclosure fires [J].
Delichatsios, MA ;
Silcock, GWH ;
Liu, XJ ;
Delichatsios, M ;
Lee, YP .
FIRE SAFETY JOURNAL, 2004, 39 (01) :1-21
[8]   Modeling thermal behaviors of window flame ejected from a fire compartment [J].
Himoto, Keisuke ;
Tsuchihashi, Tsuneto ;
Tanaka, Yoshiaki ;
Tanaka, Takeyoshi .
FIRE SAFETY JOURNAL, 2009, 44 (02) :230-240
[9]  
Karlsson B., 2000, Enclosure Fire dynamicsM
[10]  
Larsen T. S, 2007, NATURAL VENTILATION