Comparison of the Efficacy of Different Arterial Waveform-Derived Variables (Pulse Pressure Variation, Stroke Volume Variation, Systolic Pressure Variation) for Fluid Responsiveness in Hemodynamically Unstable Mechanically Ventilated Critically III Patients

被引:2
|
作者
Kumar, Nitish [1 ]
Malviya, Deepak [1 ]
Nath, Soumya S. [1 ]
Rastogi, Shivani [1 ]
Upadhyay, Vishal [1 ]
机构
[1] Dr Ram Manohar Lohia Inst Med Sci, Dept Anesthesiol & Crit Care Med, Lucknow, Uttar Pradesh, India
关键词
Cardiac index; Positive end expiratory pressure; Pulse pressure variation; Stroke volume variation; Systolic pressure variation; THERAPY;
D O I
10.5005/jp-journals-10071-23440
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction:This study was conducted to assess fluid responsiveness in critically ill patients to avoid various complications of fluid overload. Material and methods: This study was done in an ICU of a tertiary care hospital after approval from the institute ethical committee over 18 months. A total of 54 consenting adult patients were included In the study. Patients were hemodynamically unstable requiring mechanical ventilation, had acute circulatory failure, or those with at least one clinical sign of inadequate tissue perfusion. All patients were ventilated using tidal volume of 6-8 ml/kg, RR-12-15/minutes, positive end expiratory pressure (PEEP)-5 cm of water, and plateau pressure was kept below 30 cm water. They were sedated throughout the study. The arterial line and the central venous catheter were placed and connected to Vigileo-FloTrac transducer (Edward Lifesciences). Patients were classified into responder and nonresponder groups on the basis of the cardiac Index (CI) after fluid challenge of 10 mL/kg of normal saline over 30 minutes. Pulse pressure variation (PPV), stroke volume variation (SW), and systolic pressure variation (SPV) were assessed and compared at baseline, 30 minutes, and 60 minutes. Results: in our study we found that PPV and SW were significantly lower among responders than nonresponders at 30 minutes and insignificant at 60 minutes. Stroke volume variation was 10.28 +/- 1.76 in the responder compared to 12.28 +/- 4.42 (p = 0.02) at 30 minutes and PPV was 15.28 +/- 6.94 in responders while It was 20.03 +/- 4.35 in nonresponders (p = 0.01). We found SPV was insignificant at all time periods among both groups. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 47 条
  • [21] How accurate are different arterial pressure-derived estimates of cardiac output and stroke volume variation measures in critically ill patients?
    B Lamia
    HK Kim
    A Hefner
    D Severyn
    H Gomez
    JC Puyana
    MR Pinsky
    Critical Care, 12 (Suppl 2):
  • [22] Prediction of fluid responsiveness in septic shock patients: comparing automated pulse pressure variation by IntelliVue MP monitor and stroke volume variation by FloTrac™/Vigileo™
    B Khwannimit
    R Bhurayanontachai
    Critical Care, 15 (Suppl 1):
  • [23] Stroke volume variation as a predictor of fluid responsiveness in patients undergoing airway pressure release ventilation
    Suehiro, K.
    Rinka, H.
    Ishikawa, J.
    Fuke, A.
    Arimoto, H.
    Miyaichi, T.
    ANAESTHESIA AND INTENSIVE CARE, 2012, 40 (05) : 767 - 772
  • [24] The Changes in Pulse Pressure Variation or Stroke Volume Variation After a "Tidal Volume Challenge" Reliably Predict Fluid Responsiveness During Low Tidal Volume Ventilation
    Myatra, Sheila Nainan
    Prabu, Natesh R.
    Vasishtha, Jigeeshu
    Monnet, Xavier
    Kulkarni, Atul Prabhakar
    Teboul, Jean-Louis
    CRITICAL CARE MEDICINE, 2017, 45 (03) : 415 - 421
  • [25] Accuracy of stroke volume variation compared with pleth variability index to predict fluid responsiveness in mechanically ventilated patients undergoing major surgery
    Zimmermann, Markus
    Feibicke, Thomas
    Keyl, Cornelius
    Prasser, Christopher
    Moritz, Stefan
    Graf, Bernhard M.
    Wiesenack, Christoph
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2010, 27 (06) : 555 - 561
  • [26] Stroke volume and pulse pressure variation for prediction of fluid responsiveness in patients undergoing off-pump coronary artery bypass grafting
    Hofer, CK
    Müller, SM
    Furrer, L
    Klaghofer, R
    Genoni, M
    Zollinger, A
    CHEST, 2005, 128 (02) : 848 - 854
  • [27] Right ventricular and pulmonary artery pulse pressure variation and systolic pressure variation for the prediction of fluid responsiveness: an interventional study in coronary artery bypass surgery patients
    Flick, Moritz
    Sand, Ulrike
    Bergholz, Alina
    Kouz, Karim
    Reiter, Beate
    Flotzinger, Doris
    Saugel, Bernd
    Kubitz, Jens Christian
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2022, 36 (06) : 1817 - 1825
  • [28] Changes in pulse pressure variation to assess preload responsiveness in mechanically ventilated patients with spontaneous breathing activity: an observational study
    Hamzaoui, Olfa
    Shi, Rui
    Carelli, Simone
    Sztrymf, Benjamin
    Prat, Dominique
    Jacobs, Frederic
    Monnet, Xavier
    Gouezel, Corentin
    Teboul, Jean-Louis
    BRITISH JOURNAL OF ANAESTHESIA, 2021, 127 (04) : 532 - 538
  • [29] Comparison of pulse pressure variation with radial arterial systolic, diastolic and pulse transit time interval variation in pediatric patients undergoing liver transplantation
    YJ Moon
    IG Jun
    WJ Shin
    BH Sang
    GS Hwang
    Critical Care, 17 (Suppl 2):
  • [30] Evaluation of pulse pressure variation and pleth variability index to predict fluid responsiveness in mechanically ventilated isoflurane-anesthetized dogs
    Sano, Hiroki
    Seo, Joonbum
    Wightman, Paul
    Cave, Nick J.
    Gieseg, Mike A.
    Johnson, Craig B.
    Chambers, Paul
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2018, 28 (04) : 301 - 309