Comparison of the Efficacy of Different Arterial Waveform-Derived Variables (Pulse Pressure Variation, Stroke Volume Variation, Systolic Pressure Variation) for Fluid Responsiveness in Hemodynamically Unstable Mechanically Ventilated Critically III Patients

被引:2
|
作者
Kumar, Nitish [1 ]
Malviya, Deepak [1 ]
Nath, Soumya S. [1 ]
Rastogi, Shivani [1 ]
Upadhyay, Vishal [1 ]
机构
[1] Dr Ram Manohar Lohia Inst Med Sci, Dept Anesthesiol & Crit Care Med, Lucknow, Uttar Pradesh, India
关键词
Cardiac index; Positive end expiratory pressure; Pulse pressure variation; Stroke volume variation; Systolic pressure variation; THERAPY;
D O I
10.5005/jp-journals-10071-23440
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction:This study was conducted to assess fluid responsiveness in critically ill patients to avoid various complications of fluid overload. Material and methods: This study was done in an ICU of a tertiary care hospital after approval from the institute ethical committee over 18 months. A total of 54 consenting adult patients were included In the study. Patients were hemodynamically unstable requiring mechanical ventilation, had acute circulatory failure, or those with at least one clinical sign of inadequate tissue perfusion. All patients were ventilated using tidal volume of 6-8 ml/kg, RR-12-15/minutes, positive end expiratory pressure (PEEP)-5 cm of water, and plateau pressure was kept below 30 cm water. They were sedated throughout the study. The arterial line and the central venous catheter were placed and connected to Vigileo-FloTrac transducer (Edward Lifesciences). Patients were classified into responder and nonresponder groups on the basis of the cardiac Index (CI) after fluid challenge of 10 mL/kg of normal saline over 30 minutes. Pulse pressure variation (PPV), stroke volume variation (SW), and systolic pressure variation (SPV) were assessed and compared at baseline, 30 minutes, and 60 minutes. Results: in our study we found that PPV and SW were significantly lower among responders than nonresponders at 30 minutes and insignificant at 60 minutes. Stroke volume variation was 10.28 +/- 1.76 in the responder compared to 12.28 +/- 4.42 (p = 0.02) at 30 minutes and PPV was 15.28 +/- 6.94 in responders while It was 20.03 +/- 4.35 in nonresponders (p = 0.01). We found SPV was insignificant at all time periods among both groups. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences. Conclusion: We can conclude that initial assessment for fluid responsiveness in critically ill mechanically ventilated patients should be based on PPV and SW to prevent complications of fluid overload and their consequences.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 47 条
  • [1] Comparison of pulse pressure variation versus echocardiography-derived stroke volume variation for prediction of fluid responsiveness in mechanically ventilated anesthetized dogs
    Goncalves, Lucas A.
    Otsuki, Denise A.
    Pereira, Marco A. A.
    Nagashima, Julio K.
    Ambrosio, Aline M.
    Fantoni, Denise T.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2020, 47 (01) : 28 - 37
  • [2] Pulse pressure variation and stroke volume variation predict fluid responsiveness in mechanically ventilated patients experiencing intra-abdominal hypertension
    Liu, Xiaomei
    Fu, Qiang
    Mi, Weidong
    Liu, Henian
    Zhang, Hong
    Wang, Peiji
    BIOSCIENCE TRENDS, 2013, 7 (02) : 101 - 108
  • [3] Stroke volume variation (SVV) and pulse pressure variation (PPV) as indicators of fluid responsiveness in sevoflurane anesthetized mechanically ventilated euvolemic dogs
    Endo, Yusuke
    Tamura, Jun
    Ishizuka, Tomohito
    Itami, Takaharu
    Hanazono, Kiwamu
    Miyoshi, Kenjiro
    Sano, Tadashi
    Yamashita, Kazuto
    Muir, William W.
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2017, 79 (08) : 1437 - 1445
  • [4] Comparison between pulse pressure variation and systolic pressure variation measured from a peripheral artery for accurately predicting fluid responsiveness in mechanically ventilated dogs
    Dalmagro, Tabata L.
    Teixeira-Neto, Francisco J.
    Celeita-Rodriguez, Nathalia
    Garofalo, Natache A.
    Lopez-Castaneda, Brayan
    do Nascimento-Junior, Paulo
    VETERINARY ANAESTHESIA AND ANALGESIA, 2021, 48 (04) : 501 - 508
  • [5] Is the pulse pressure variation a good predictor of fluid responsiveness in mechanically ventilated patients with low tidal volume?
    C Costa
    S Vieira
    G Friedman
    L Fialkow
    Critical Care, 13 (Suppl 1):
  • [6] Predictive values of pulse pressure variation and stroke volume variation for fluid responsiveness in patients with pneumoperitoneum
    Zlicar, Marko
    Novak-Jankovic, Vesna
    Blagus, Rok
    Cecconi, Maurizio
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2018, 32 (05) : 825 - 832
  • [7] Comparison Between Changes in Systolic-Pressure Variation and Pulse-Pressure Variation After Passive Leg Raising to Predict Fluid Responsiveness in Postoperative Critically Ill Patients
    Xie, Jin
    Xu, Li
    Peng, Ke
    Chen, Jun
    Wan, Jingjie
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2024, 38 (02) : 459 - 465
  • [8] Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model
    Renner, Jochen
    Gruenewald, Matthias
    Quaden, Rene
    Hanss, Robert
    Meybohm, Patrick
    Steinfath, Markus
    Scholz, Jens
    Bein, Berthold
    CRITICAL CARE MEDICINE, 2009, 37 (02) : 650 - 658
  • [9] Evaluation of stroke volume variation and pulse pressure variation as predictors of fluid responsiveness in patients undergoing protective one-lung ventilation
    Fu, Qiang
    Duan, Mingda
    Zhao, Feng
    Mi, Weidong
    DRUG DISCOVERIES AND THERAPEUTICS, 2015, 9 (04) : 296 - 302
  • [10] Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease
    Kim, So Yeon
    Song, Young
    Shim, Jae Kwang
    Kwak, Young Lan
    JOURNAL OF CRITICAL CARE, 2013, 28 (03) : 318.e1 - 318.e7