Tensile Stimulation of Murine Stem Cell-Collagen Sponge Constructs Increases Collagen Type I Gene Expression and Linear Stiffness

被引:0
作者
Chokalingam, Kumar [1 ]
Juncosa-Melvin, Natalia [2 ]
Hunter, Shawn A. [3 ]
Gooch, Cynthia [1 ]
Frede, Chris [4 ]
Florert, Jane [4 ]
Bradica, Gino [5 ]
Wenstrup, Richard [6 ]
Butler, David L. [1 ]
机构
[1] Univ Cincinnati, Dept Biomed Engn, Cincinnati, OH 45221 USA
[2] Cardioenergetics Inc, Cincinnati, OH USA
[3] Community Tissue Serv, Dayton, OH USA
[4] Cincinnati Childrens Hosp, Med Ctr, Dept Human Genet, Cincinnati, OH USA
[5] Kensey Nash Corp, Exton, PA USA
[6] Myriad Genet Inc, Salt Lake City, UT USA
关键词
ANTERIOR CRUCIATE LIGAMENT; MECHANICAL STIMULATION; BONE-MARROW; SUPRASPINATUS TENDON; REPAIR BIOMECHANICS; TISSUE; MATRIX; RECONSTRUCTION; STRAIN; FORCES;
D O I
10.1089/ten.tea.2008.0451
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The objectives of this study were to determine how tensile stimulation delivered up to 14 days in culture influenced type I collagen gene expression in stem cells cultured in collagen sponges, and to establish if gene expression, measured using a fluorescence method, correlates with an established method, real-time quantitative reverse transcriptase polymerase chain reaction (qRT-PCR). Using a novel model system, mesenchymal stem cells were harvested from six double transgenic mice in which the type I and type II collagen promoters were linked to green fluorescent protein-topaz and enhanced cyan fluorescent protein, respectively. Tissue-engineered constructs were created by seeding 0.5 x 10(6) mesenchymal stem cells onto type I collagen sponge scaffolds in a silicone dish. Constructs were then transferred to a custom pneumatic mechanical stimulation system housed in a standard incubator and stimulated for 5 h/day in tension for either 7 or 14 days using a repeated profile (2.4% peak strain for 20 s at 1 Hz followed by a rest period at 0% strain for 100 s). Control specimens were exposed to identical culture conditions but without mechanical stimulation. At three time points (0, 7, and 14 days), constructs were then prepared for evaluation of gene expression using fluorescence analysis and qRT-PCR, and the remaining constructs were failed in tension. Both analytical methods showed that constructs stimulated for 7 and 14 days showed significantly higher collagen type I gene expression than nonstimulated controls at the same time interval. Gene expression measured using qRT-PCR and fluorescence analysis was positively correlated (r = 0.9). Linear stiffness of stimulated constructs was significantly higher at both 7 and 14 days than that of nonstimulated controls at the same time intervals. Linear stiffness of the stimulated constructs at day 14 was significantly different from that of day 7. Future studies will vary themechanical signal to optimize type I collagen gene expression to improve construct biomechanics and in vivo tendon repair.
引用
收藏
页码:2561 / 2570
页数:10
相关论文
共 68 条
[1]  
ALBRIGHT JC, 1999, ORTHOP KNOWLEDGE UPD, V20, P281
[2]   Cell differentiation by mechanical stress [J].
Altman, GH ;
Horan, RL ;
Martin, I ;
Farhadi, J ;
Stark, PRH ;
Volloch, V ;
Richmond, JC ;
Vunjak-Novakovic, G ;
Kaplan, DL .
FASEB JOURNAL, 2001, 15 (14) :270-+
[3]  
Amiel D., 1990, Knee ligaments: structure, function, injury and repair, P77
[4]   Stretch and interleukin-1β induce matrix metalloproteinases in rabbit tendon cells in vitro [J].
Archambault, J ;
Tsuzaki, M ;
Herzog, W ;
Banes, AJ .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2002, 20 (01) :36-39
[5]   Repair of patellar tendon injuries using a cell-collagen composite [J].
Awad, HA ;
Boivin, GP ;
Dressler, MR ;
Smith, FNL ;
Young, RG ;
Butler, DL .
JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (03) :420-431
[7]   Intratendinous strain fields of the supraspinatus tendon: Effect of a surgically created articular-surface rotator cuff tear [J].
Bey, MJ ;
Ramsey, ML ;
Soslowsky, LJ .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2002, 11 (06) :562-569
[8]   Autologous perichondral tissue for meniscal replacement [J].
Bruns, J ;
Kahrs, J ;
Kampen, J ;
Behrens, P ;
Plitz, W .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1998, 80B (05) :918-923
[9]   Functional tissue engineering parameters toward designing repair and replacement strategies [J].
Butler, DL ;
Shearn, JT ;
Juncosa, N ;
Dressler, MR ;
Hunter, SA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (427) :S190-S199
[10]   Functional efficacy of tendon kepair processes [J].
Butler, DL ;
Juncosa, N ;
Dressler, MR .
ANNUAL REVIEW OF BIOMEDICAL ENGINEERING, 2004, 6 :303-329