摘要
Introduction: Mini-implants are often immediately loaded for orthodontic treatment; however, changes in interfacial tissues caused by early loading and its effects might compromise the mini-implant's function. The purpose of this study was to compare the healing of interfacial tissues 1, 4, and 12 weeks after the placement of titanium-alloy mini-implants in New Zealand rabbits; some of the implants were loaded immediately and others were left unloaded. Methods: Eighteen animals were used in the experiment. Each received 4 titanium grade 5 mini-implants (2.0 x 6.0 mm), 2 of which were immediately loaded with 1 N of force. Tissue healing was verified at 1, 4, and 12 weeks after placement. Four different fluorescent molecules were injected into the rabbits to label calcium deposition. After the rabbits were killed, mineralized bone samples with the mini-implants were removed, fixed, cut, stained, and observed with bright-field, polarized, and fluorescence microscopy. Results: After 12 weeks of healing, higher bone contact and bone area were observed than after 1 or 4 weeks, regardless of loading. Differences between the loaded and unloaded groups were not observed (P < 0.05) at 1 and 4 weeks. The bone deposition rate was higher in the loaded group. Conclusions: The 1-N immediate force application did not compromise bone formation around mini-implants. (Am J Orthod Dentofacial Orthop 2010; 137:80-90)
引用
收藏
页码:80 / 90
页数:11
相关论文
共 46 条
  • [1] Long-term evaluation of sandblasted and acid-etched implants used as orthodontic anchors in dogs
    Aldikaçti, M
    Açikgöz, G
    Türk, T
    Trisi, P
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2004, 125 (02) : 139 - 147
  • [2] Load-related implant reaction of mini-implants used for orthodontic anchorage
    Büchter, A
    Wiechmann, D
    Koerdt, S
    Wiesmann, HP
    Piffko, J
    Meyer, U
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2005, 16 (04) : 473 - 479
  • [3] Load-related bone modelling at the interface of orthodontic micro-implants
    Buechter, Andre
    Wiechmann, Dirk
    Gaertner, Christoph
    Hendrik, Marc
    Vogeler, Martin
    Wiesmann, Hans Peter
    Piffko, Josef
    Meyer, Ulrich
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (06) : 714 - 722
  • [4] Chen FS, 2005, ANGLE ORTHOD, V75, P593
  • [5] A clinical evaluation of titanium miniplates as anchors for orthodontic treatment
    Choi, BH
    Zhu, SJ
    Kim, YH
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2005, 128 (03) : 382 - 384
  • [6] Chung Kyu-Rhim, 2002, J Clin Orthod, V36, P407
  • [7] Cope JB., 2005, SEMIN ORTHOD, V11, P3, DOI [10.1053/j.sodo.2004.11.002, DOI 10.1053/J.SODO.2004.11.002]
  • [8] Costa A, 1998, Int J Adult Orthodon Orthognath Surg, V13, P201
  • [9] The use of small titanium screws for orthodontic anchorage
    Deguchi, T
    Takano-Yamamoto, T
    Kanomi, R
    Hartsfield, JK
    Roberts, WE
    Garetto, LP
    [J]. JOURNAL OF DENTAL RESEARCH, 2003, 82 (05) : 377 - 381
  • [10] ERIKSEN FE, 1994, BONE HISTOMORPHOMETR