Comparison of lung volume measurements by multiple-breath heptafluoropropane washout and computed tomography in small ventilated piglets

被引:0
作者
Proquitte, Hans [1 ]
Elgeti, Thomas [2 ]
Roehr, Charles C.
Rogalla, Patrik [2 ]
Wauer, Roland
Schmalisch, Gerd
机构
[1] Charite, Clin Neonatol, CCM, D-10117 Berlin, Germany
[2] Charite, Dept Radiol, D-10117 Berlin, Germany
来源
MEDICAL SCIENCE MONITOR | 2009年 / 15卷 / 10期
关键词
functional residual capacity; gated computed tomography; multiple-breath washout; heptafluoropropane; mechanical ventilation; body position; animal; newborns; FUNCTIONAL RESIDUAL CAPACITY; RESPIRATORY-DISTRESS-SYNDROME; PREMATURELY BORN INFANTS; MECHANICAL VENTILATION; CHEST RADIOGRAPH; PRETERM INFANTS; HELIUM DILUTION; FUNCTION TESTS; BODY POSITION; CHILDREN;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Knowledge of lung volume is essential for monitoring and optimizing mechanical ventilation. The aim of this study was to compare lung volume measurements by multiple-breath heptafluoropropane (HFP) washout. (MBW) and by respiratory gated computed tomography (CT) in ventilated newborn piglets. Material/Methods: In 6 ventilated piglets (age: <12 h, median weight: 945 g) blood gases, respiratory mechanics, and lung volumes were measured in both the supine and prone positions. The measurements were performed in random order. Functional residual capacity (FRC) was measured simultaneously by HFP MBW (FRCHFP) using a new infrared mainstream sensor and by CT (FRCCT) at the end of inspiration and expiration (multi-slice Toshiba Aquilon 16, Otawara, japan). Tidal volume (V-T) was measured both by the Drager Babylog 8000 ventilator (V-TBL) and the volume difference of the CT scans (V-TCT). Results: FRCHFP (25.2 +/- 8.5 ml) and FRCCT (24.9 +/- 7.6 ml) correlated strongly (gamma=0.97) without significant bias. Bland-Altman limits of agreement showed differences between the two methods that ranged from -19.7 to +19.5%. A similar strong correlation without statistically significant bias was found between V-TBL (8.5 +/- 2.0 ml) and V-TCT (9.0 +/- 2.4 ml) with gamma=0.91. The limits of agreement were -24.4 and +14.0%. Body position (prone vs. supine) had no significant effect on blood gases, respiratory mechanics, or lung volumes. Conclusions: Lung volumes measured in small ventilated lungs by HFP washout and CT are highly correlated and independent of body position. However, the relatively large limits of agreement indicate differences in the two techniques.
引用
收藏
页码:BR275 / BR280
页数:6
相关论文
共 40 条
  • [1] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [2] Bober K, 2006, MED SCI MONITOR, V12, pCR440
  • [3] Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study
    Brix, G
    Lechel, U
    Veit, R
    Truckenbrodt, R
    Stamm, G
    Coppenrath, EM
    Griebel, J
    Nagel, HD
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (07) : 1275 - 1284
  • [4] Effect of prone positioning on clinical outcomes in children with acute lung injury - A randomized controlled trial
    Curley, MAQ
    Hibberd, PL
    Fineman, LD
    Wypij, D
    Shih, MC
    Thompson, J
    Grant, MJC
    Barr, FE
    Cvijanovich, NZ
    Sorce, L
    Luckett, PM
    Matthay, MA
    Arnold, JH
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2005, 294 (02): : 229 - 237
  • [5] Computer assisted analysis of the chest radiograph lung area and prediction of failure of extubation from mechanical ventilation in preterm neonates
    Dimitriou, G
    Greenough, A
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (866) : 156 - 159
  • [6] A radiographic method for assessing lung area in neonates
    Dimitriou, G
    Greenough, A
    Kavvadia, V
    Shute, M
    Karani, J
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (856) : 335 - 338
  • [7] Effect of PEEP and suction via chest drain on functional residual capacity and lung compliance after surgical repair of congenital diaphragmatic hernia: Preliminary observations in 5 patients
    Dinger, J
    Peter-Kern, M
    Goebel, P
    Roesner, D
    Schwarze, R
    [J]. JOURNAL OF PEDIATRIC SURGERY, 2000, 35 (10) : 1482 - 1488
  • [8] Functional residual capacity and compliance of the respiratory system after surfactant treatment in premature infants with severe respiratory distress syndrome
    Dinger, J
    Töpfer, A
    Schaller, P
    Schwarze, R
    [J]. EUROPEAN JOURNAL OF PEDIATRICS, 2002, 161 (09) : 485 - 490
  • [9] Electrical impedance tomography in extremely prematurely born infants and during high frequency oscillatory ventilation analyzed in the frequency domain
    Dunlop, Scott
    Hough, Judy
    Riedel, Thomas
    Fraser, John F.
    Dunster, Kimble
    Schibler, Andreas
    [J]. PHYSIOLOGICAL MEASUREMENT, 2006, 27 (11) : 1151 - 1165
  • [10] Dynamic computed tomography of the neonatal lung -: Volume calculations and validation in an animal model
    Elgeti, T
    Proquitté, H
    Rogalla, NE
    Mews, J
    Wauer, R
    Hamm, B
    Schmalisch, G
    Rogalla, P
    [J]. INVESTIGATIVE RADIOLOGY, 2005, 40 (12) : 761 - 765