Kinetic Inductance Detectors for the OLIMPO experiment: in-flight operation and performance

被引:34
作者
Masi, S. [1 ,2 ]
de Bernardis, P. [1 ,2 ]
Paiella, A. [1 ,2 ]
Piacentini, F. [1 ,2 ]
Lamagna, L. [1 ,2 ]
Coppolecchia, A. [1 ,2 ]
Ade, P. A. R. [3 ]
Battistelli, E. S. [1 ,2 ]
Castellano, M. G. [4 ]
Colantoni, I. [4 ,5 ]
Columbro, F. [1 ,2 ]
D'Alessandro, G. [1 ,2 ]
De Petris, M. [1 ,2 ]
Gordon, S. [6 ]
Magneville, C. [7 ]
Mauskopf, P. [6 ,8 ]
Pettinari, G. [4 ]
Pisano, G. [3 ]
Polenta, G. [9 ]
Presta, G. [1 ,2 ]
Tommasi, E. [9 ]
Tucker, C. [3 ]
Vdovin, V. [10 ,11 ]
Volpe, A. [9 ]
Yvon, D. [7 ]
机构
[1] Sapienza Univ Roma, Dipartimento Fis, Ple A Moro 2, I-00185 Rome, Italy
[2] Ist Nazl Fis Nucl, Sez Roma, Ple A Moro 2, I-00185 Rome, Italy
[3] Cardiff Univ, Sch Phys & Astron, Cardiff CF24 3YB, S Glam, Wales
[4] CNR, Ist Foton & Nanotecnol, Via Cineto Romano 42, I-00156 Rome, Italy
[5] Sapienza Univ Roma, Inst Nanotechnol, CNR Nanotech, Dipartimento Fis, Ple A Moro 2, I-00185 Rome, Italy
[6] Arizona State Univ, Sch Earth & Space Explorat, Tempe, AZ 85287 USA
[7] Univ Paris Saclay, IRFU, CEA, F-91191 Gif Sur Yvette, France
[8] Arizona State Univ, Dept Phys, Tempe, AZ 85257 USA
[9] Italian Space Agcy, Rome, Italy
[10] State Tech Univ, Inst Appl Phys RAS, Nizhnij Novgorov, Russia
[11] ASC Lebedev PI RAS, Moscow, Russia
关键词
CMBR detectors; CMBR experiments; Sunyaev-Zeldovich effect; THERMAL-CONDUCTIVITY; INSTRUMENT; BOOMERANG; DESIGN; SKY;
D O I
10.1088/1475-7516/2019/07/003
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
We report on the performance of lumped-elements Kinetic Inductance Detector (KID) arrays for mm and sub-mm wavelengths, operated at 0.3 K during the stratospheric flight of the OLIMPO payload, at an altitude of 37.8 km. We find that the detectors can be tuned in-flight, and their performance is robust against radiative background changes due to varying telescope elevation. We also find that the noise equivalent power of the detectors in flight is smaller by a factor of similar to 2, 8, 3.5, 4.5 at 150, 250, 350 and 460 GHz relative to the one measured in the laboratory, and is close to our calculated photon-noise-limited performance. The effect of primary cosmic rays crossing the detector is found to be consistent with the expected ionization energy loss with phonon-mediated energy transfer from the ionization sites to the resonators. In the OLIMPO detector arrays, at float, cosmic ray events affect less than 4% of the detector samplings for all the pixels of all the arrays, and less than 1% of the samplings for most of the pixels. These results are also representative of what one can expect from primary cosmic rays in a satellite mission with similar KIDs and instrument environment.
引用
收藏
页数:26
相关论文
共 46 条
[11]  
[Anonymous], 2013, NEW HORIZONS OBS COS, DOI DOI 10.3254/978-1-61499-476-3-257
[12]  
[Anonymous], ASTRON ASTROPHYS
[13]   Millimeter-Wave Polarimeters Using Kinetic Inductance Detectors for TolTEC and Beyond [J].
Austermann, J. E. ;
Beall, J. A. ;
Bryan, S. A. ;
Dober, B. ;
Gao, J. ;
Hilton, G. ;
Hubmayr, J. ;
Mauskopf, P. ;
McKenney, C. M. ;
Simon, S. M. ;
Ullom, J. N. ;
Vissers, M. R. ;
Wilson, G. W. .
JOURNAL OF LOW TEMPERATURE PHYSICS, 2018, 193 (3-4) :120-127
[14]   A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors [J].
Baselmans, J. J. A. ;
Bueno, J. ;
Yates, S. J. C. ;
Yurduseven, O. ;
Llombart, N. ;
Karatsu, K. ;
Baryshev, A. M. ;
Ferrari, L. ;
Endo, A. ;
Thoen, D. J. ;
de Visser, P. J. ;
Janssen, R. M. J. ;
Murugesan, V. ;
Driessen, E. F. C. ;
Coiffard, G. ;
Martin-Pintado, J. ;
Hargrave, P. ;
Griffin, M. .
ASTRONOMY & ASTROPHYSICS, 2017, 601
[15]   Archeops:: a high resolution, large sky coverage balloon experiment for mapping cosmic microwave background anisotropies [J].
Benoît, A ;
Ade, P ;
Amblard, A ;
Ansari, R ;
Aubourg, E ;
Bartlett, J ;
Bernard, JP ;
Bhatia, RS ;
Blanchard, A ;
Bock, JJ ;
Boscaleri, A ;
Bouchet, FR ;
Bourrachot, A ;
Camus, P ;
Couchot, F ;
de Bernardis, P ;
Delabrouille, J ;
Désert, FX ;
Doré, O ;
Douspis, M ;
Dumoulin, L ;
Dupac, X ;
Filliatre, P ;
Ganga, K ;
Gannaway, F ;
Gautier, B ;
Giard, M ;
Giraud-Héraud, Y ;
Gispert, R ;
Guglielmi, L ;
Hamilton, JC ;
Hanany, S ;
Henrot-Versillé, S ;
Hristov, VV ;
Kaplan, J ;
Lagache, G ;
Lamarre, JM ;
Lange, AE ;
Madet, K ;
Maffei, B ;
Marrone, D ;
Masi, S ;
Murphy, JA ;
Naraghi, F ;
Nati, F ;
Perrin, G ;
Piat, M ;
Puget, JL ;
Santos, D ;
Sudiwala, RV .
ASTROPARTICLE PHYSICS, 2002, 17 (02) :101-124
[16]   High sensitivity phonon-mediated kinetic inductance detector with combined amplitude and phase read-out [J].
Cardani, L. ;
Casali, N. ;
Colantoni, I. ;
Cruciani, A. ;
Bellini, F. ;
Castellano, M. G. ;
Cosmelli, C. ;
D'Addabbo, A. ;
Di Domizio, S. ;
Martinez, M. ;
Tomei, C. ;
Vignati, M. .
APPLIED PHYSICS LETTERS, 2017, 110 (03)
[17]   RADIATION HARDNESS OF A COMPOSITE BOLOMETER COOLED AT HE-3 TEMPERATURE [J].
CASERTA, A ;
DEBERNARDIS, P ;
MASI, S ;
MATTIOLI, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 294 (1-2) :328-334
[18]   Maturity of lumped element kinetic inductance detectors for space-borne instruments in the range between 80 and 180 GHz [J].
Catalano, A. ;
Benoit, A. ;
Bourrion, O. ;
Calvo, M. ;
Coiffard, G. ;
D'Addabbo, A. ;
Goupy, J. ;
Le Sueur, H. ;
Macias-Perez, J. ;
Monfardini, A. .
ASTRONOMY & ASTROPHYSICS, 2016, 592
[19]   Impact of particles on the Planck HFI detectors: Ground-based measurements and physical interpretation [J].
Catalano, A. ;
Ade, P. ;
Atik, Y. ;
Benoit, A. ;
Breele, E. ;
Bock, J. J. ;
Camus, P. ;
Chabot, M. ;
Charra, M. ;
Crill, B. P. ;
Coron, N. ;
Coulais, A. ;
Desert, F-X ;
Fauvet, L. ;
Giraud-Heraud, Y. ;
Guillaudin, O. ;
Holmes, W. ;
Jones, W. C. ;
Lamarre, J. -M. ;
Macias-Perez, J. ;
Martinez, M. ;
Miniussi, A. ;
Monfardini, A. ;
Pajot, F. ;
Patanchon, G. ;
Pelissier, A. ;
Piat, M. ;
Puget, J. -L. ;
Renault, C. ;
Rosset, C. ;
Santos, D. ;
Sauve, A. ;
Spencer, L. D. ;
Sudiwala, R. .
ASTRONOMY & ASTROPHYSICS, 2014, 569
[20]   Performance and calibration of the NIKA camera at the IRAM 30 m telescope [J].
Catalano, A. ;
Calvo, M. ;
Ponthieu, N. ;
Adam, R. ;
Adane, A. ;
Ade, P. ;
Andre, P. ;
Beelen, A. ;
Belier, B. ;
Benoit, A. ;
Bideaud, A. ;
Billot, N. ;
Boudou, N. ;
Bourrion, O. ;
Coiffard, G. ;
Comis, B. ;
D'Addabbo, A. ;
Desert, F. -X. ;
Doyle, S. ;
Goupy, J. ;
Kramer, C. ;
Leclercq, S. ;
Macias-Perez, J. F. ;
Martino, J. ;
Mauskopf, P. ;
Mayet, F. ;
Monfardini, A. ;
Pajot, F. ;
Pascale, E. ;
Perotto, L. ;
Reveret, V. ;
Rodriguez, L. ;
Savini, G. ;
Schuster, K. ;
Sievers, A. ;
Tucker, C. ;
Zylka, R. .
ASTRONOMY & ASTROPHYSICS, 2014, 569