Internal reduction established by occiput-C2 pedicle polyaxial screw stabilization in pediatric atlantoaxial rotatory fixation

被引:20
作者
Belen, Deniz [1 ]
Simsek, Serkan [1 ]
Yigitkanli, Kazim [1 ]
Bavbek, Murad [1 ]
机构
[1] Educ Hosp Soc Secur Institut, Dept Neurosurg, Ankara, Turkey
关键词
atlantoaxial subluxation; craniocervical instability; Griesel's syndrome; pediatric cervical spine;
D O I
10.1159/000094073
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Atlantoaxial rotatory fixation is an uncommon disorder of childhood, which can be treated conservatively when diagnosed early. Although spontaneous correction occasionally occurs, most of the patients usually benefit from collar or traction therapies. If there is no intervention or if all external therapeutic modalities fail, the deformity may become chronic and irreducible. In such rare cases, surgical correction and stabilization are needed to prevent future head and neck deformity or facial asymmetry. In this report we describe a novel surgical technique used in a pediatric case presenting with delayed type 2 atlantoaxial rotatory fixation, in whom all external reduction methods had failed. The patient's deformity was treated by occiput-C-2 pedicle polyaxial screw stabilization. This technique is effective for reducing the atlantoaxial fixation in children. Copyright (c) 2006 S. Karger AG, Basel.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 26 条
[1]   Posterior occipitocervical reconstruction using cervical pedicle screws and plate-rod systems [J].
Abumi, K ;
Takada, T ;
Shono, Y ;
Kaneda, K ;
Fujiya, M .
SPINE, 1999, 24 (14) :1425-1434
[2]   TRANSPEDICULAR SCREW FIXATION FOR TRAUMATIC LESIONS OF THE MIDDLE AND LOWER CERVICAL-SPINE - DESCRIPTION OF THE TECHNIQUES AND PRELIMINARY-REPORT [J].
ABUMI, K ;
ITOH, H ;
TANEICHI, H ;
KANEDA, K .
JOURNAL OF SPINAL DISORDERS, 1994, 7 (01) :19-28
[3]   Open reduction of pediatric atlantoaxial rotatory fixation: long-term outcome study with functional measurements [J].
Crossman, JE ;
David, K ;
Hayward, R ;
Crockard, HA .
JOURNAL OF NEUROSURGERY, 2004, 100 (03) :235-240
[4]   Posterior C1-C2 transarticular screw fixation for atlantoaxial arthrodesis [J].
Dickman, CA ;
Sonntag, VKH .
NEUROSURGERY, 1998, 43 (02) :275-280
[5]   Anatomic consideration of C2 pedicle screw placement [J].
Ebraheim, N ;
Rollins, JR ;
Xu, RM ;
Jackson, WT .
SPINE, 1996, 21 (06) :691-694
[6]   ATLANTO-AXIAL ROTATORY FIXATION - (FIXED ROTATORY SUBLUXATION OF ATLANTO-AXIAL JOINT) [J].
FIELDING, JW ;
HAWKINS, RJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1977, 59 (01) :37-44
[7]   ATLANTOAXIAL ROTATORY FIXATION AND FRACTURE OF THE CLAVICLE - AN ASSOCIATION AND A CLASSIFICATION [J].
GODDARD, NJ ;
STABLER, J ;
ALBERT, JS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :72-75
[8]   PLATE AND SCREW FIXATION FOR ATLANTOAXIAL SUBLUXATION [J].
GOEL, A ;
LAHERI, V .
ACTA NEUROCHIRURGICA, 1994, 129 (1-2) :47-53
[9]   SPINAL-INJURIES IN CHILDREN [J].
GOVENDER, S ;
CHARLES, RW ;
RASOOL, MN .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1990, 21 (06) :403-406
[10]   Staged reduction and stabilisation in chronic atlantoaxial rotatory fixation [J].
Govender, S ;
Kumar, KPS .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B (05) :727-731