Liquid phase determination of adrenaline uses a voltammetric sensor employing CuFe2O4 nanoparticles and room temperature ionic liquids

被引:104
作者
Bavandpour, Razie [1 ]
Karimi-Maleh, Hassan [1 ]
Asif, Mohammad [2 ]
Gupta, Vinod Kumar [3 ,4 ]
Atar, Necip [5 ]
Abbasghorbani, Maryam [6 ]
机构
[1] Grad Univ Adv Technol, Dept Chem, Kerman, Iran
[2] King Saud Univ, Dept Chem Engn, Riyadh, Saudi Arabia
[3] Indian Inst Technol, Dept Chem, Roorkee 247667, Uttar Pradesh, India
[4] Univ Johannesburg, Dept Appl Chem, Johannesburg, South Africa
[5] Pamukkale Univ, Dept Chem Engn, Denizli, Turkey
[6] Res Inst Petr Ind, Gas Div, POB 14665-137, Tehran, Iran
关键词
Adrenaline; CuFe2O4; nanoparticles; Ionic liquids; Modified electrode; CARBON-PASTE ELECTRODE; CONTINUOUS CYCLIC VOLTAMMETRY; PYROLYTIC-GRAPHITE ELECTRODE; GRAPHENE-MODIFIED ELECTRODES; POLY(VINYL CHLORIDE) MATRIX; ELECTROCHEMICAL-BEHAVIOR; GOLD NANOPARTICLES; FOOD SAMPLES; FOLIC-ACID; SUDAN I;
D O I
10.1016/j.molliq.2015.07.054
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A highly sensitive and quick voltammetric sensor based on CuFe2O4 nanoparticle/room temperature ionic liquids carbon paste electrode (CuFe2O4/ILs/CFE) is proposed for the determination of adrenaline in the biological condition (pH = 7.4). CuFe2O4 are nanoparticles synthesized by co-precipitation method and characterized with different methods such as transmission electron microscopy (TEM) and X-ray diffraction (XRD). In continuous, we study application of the CuFe2O4 nanoparticle for the preparation of carbon paste electrode modified with 1,3-dipropylimidazolium bromide as a suitable and high conductive binder. At the best condition (pH 7.4), the peak currents of square wave voltammograms (SWV) of adrenaline increased linearly with its concentration in the ranges of 0.1-400 mu M. The detection limit for adrenaline was 0.07 mu M. The modified sensor has been successfully applied for the assay of adrenaline in biological and pharmaceutical samples such as urine and injection in comparison with other method. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:369 / 373
页数:5
相关论文
共 34 条
[1]   Electrochemical behavior of morphine at ZnO/CNT nanocomposite room temperature ionic liquid modified carbon paste electrode and its determination in real samples [J].
Afsharmanesh, Elahe ;
Karimi-Maleh, Hassan ;
Pahlavan, Ali ;
Vahedi, Javad .
JOURNAL OF MOLECULAR LIQUIDS, 2013, 181 :8-13
[2]   Novel 2,2′-[1,2-ethanediylbis(nitriloethylidyne)]-bis-hydroquinone double-wall carbon nanotube paste electrode for simultaneous determination of epinephrine, uric acid and folic acid [J].
Beitollahi, Hadi ;
Mazloum-Ardakani, Mohammad ;
Ganjipour, Bahram ;
Naeimi, Hossein .
BIOSENSORS & BIOELECTRONICS, 2008, 24 (03) :362-368
[3]   High sensitive voltammetric sensor based on Pt/CNTs nanocomposite modified ionic liquid carbon paste electrode for determination of Sudan I in food samples [J].
Elyasi, Mojdeh ;
Khalilzadeh, Mohammad A. ;
Karimi-Maleh, Hassan .
FOOD CHEMISTRY, 2013, 141 (04) :4311-4317
[4]   Fourier transform cyclic voltammetric technique for monitoring ultratrace amounts of salbutamol at gold ultra microelectrode in flowing solutions [J].
Ganjali, MR ;
Norouzi, P ;
Ghorbani, M ;
Sepehri, A .
TALANTA, 2005, 66 (05) :1225-1233
[5]   Simultaneous determination of adenosine and inosine using single-wall carbon nanotubes modified pyrolytic graphite electrode [J].
Goyal, Rajendra N. ;
Gupta, Vinod K. ;
Chatterjee, Sanghamitra .
TALANTA, 2008, 76 (03) :662-668
[6]   Voltammetric biosensors for the determination of paracetamol at carbon nanotube modified pyrolytic graphite electrode [J].
Goyal, Rajendra N. ;
Gupta, Vinod K. ;
Chatterjee, Sanghamitra .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 149 (01) :252-258
[7]   Neutral carriers based polymeric membrane electrodes for selective determination of mercury (II) [J].
Gupta, V. K. ;
Singh, A. K. ;
Al Khayat, A. ;
Gupta, Barkha .
ANALYTICA CHIMICA ACTA, 2007, 590 (01) :81-90
[8]   Aluminum(III) selective potentiometric sensor based on morin in poly(vinyl chloride) matrix [J].
Gupta, Vinod K. ;
Jain, Ajay K. ;
Maheshwari, Gaurav .
TALANTA, 2007, 72 (04) :1469-1473
[9]   An iron(III) ion-selective sensor based on a μ-bis(tridentate) ligand [J].
Gupta, Vinod K. ;
Jain, A. K. ;
Agarwal, Shiva ;
Maheshwari, Gaurav .
TALANTA, 2007, 71 (05) :1964-1968
[10]   Electrochemical Analysis of Some Toxic Metals by Ion-Selective Electrodes [J].
Gupta, Vinod K. ;
Ganjali, M. R. ;
Norouzi, P. ;
Khani, H. ;
Nayak, Arunima ;
Agarwal, Shilpi .
CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2011, 41 (04) :282-313