Feasibility of continuous monitoring of vital signs in surgical patients on a general ward: an observational cohort study

被引:22
|
作者
Leenen, Jobbe P. L. [1 ,2 ]
Dijkman, Eline M. [1 ]
van Dijk, Joris D. [3 ]
van Westreenen, Henderik L. [1 ]
Kalkman, Cor [4 ]
Schoonhoven, Lisette [5 ,6 ]
Patijn, Gijsbert A. [1 ]
机构
[1] Dept Surg, Isala, Zwolle, Netherlands
[2] Connected Care Ctr, Isala, Zwolle, Netherlands
[3] Isala Acad, Isala, Zwolle, Netherlands
[4] UMC Utrecht, Anesthesiol, Utrecht, Netherlands
[5] UMC Utrecht, Julius Ctr Hlth Sci & Primary Care, Utrecht, Netherlands
[6] Univ Southampton, Fac Hlth Sci, Southampton, Hants, England
来源
BMJ OPEN | 2021年 / 11卷 / 02期
关键词
surgery; health & safety; adverse events; pancreatic surgery; hepatobiliary surgery; colorectal surgery; EARLY WARNING SCORES; MORTALITY; COMPLICATIONS; IMPACT; CLASSIFICATION; SAFETY; SYSTEM;
D O I
10.1136/bmjopen-2020-042735
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective To determine feasibility, in terms of acceptability and system fidelity, of continuous vital signs monitoring in abdominal surgery patients on a general ward. Design Observational cohort study. Setting Tertiary teaching hospital. Participants Postoperative abdominal surgical patients (n=30) and nurses (n=23). Interventions Patients were continuously monitored with the SensiumVitals wearable device until discharge in addition to usual care, which is intermittent Modified Early Warning Score measurements. Heart rate, respiratory rate and axillary temperature were monitored every 2 min. Values and trends were visualised and alerts sent to the nurses. Outcomes System fidelity was measured by analysis of the monitoring data. Acceptability by patients and nurses was assessed using questionnaires. Results Thirty patients were monitored for a median duration of 81 hours (IQR 47-143) per patient, resulting in 115 217 measurements per parameter. In total, 19% (n=21 311) of heart rate, 51% (n=59 184) of respiratory rate and 9% of temperature measurements showed artefacts (n=10 269). The system algorithm sent 972 alerts (median alert rate of 4.5 per patient per day), of which 90.3% (n=878) were system alerts and 9.7% (n=94) were vital sign alerts. 35% (n=33) of vital sign alerts were true positives. 93% (n=25) of patients rated the patch as comfortable, 67% (n=18) felt safer and 89% (n=24) would like to wear it next time in the hospital. Nurses were neutral about usefulness, with a median score of 3.5 (IQR 3.1-4) on a 7-point Likert scale, ease of use 3.7 (IQR 3.2-4.8) and satisfaction 3.7 (IQR 3.2-4.8), but agreed on ease of learning at 5.0 (IQR 4.0-5.8). Neutral scores were mostly related to the perceived limited fidelity of the system. Conclusions Continuous monitoring of vital signs with a wearable device was well accepted by patients. Nurses' ratings were highly variable, resulting in on average neutral attitude towards remote monitoring. Our results suggest it is feasible to monitor vital signs continuously on general wards, although acceptability of the device among nurses needs further improvement.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Outcomes in patients receiving continuous monitoring of vital signs on general wards: A systematic review and meta-analysis of randomised controlled trials
    Bowles, Tim
    Trentino, Kevin M.
    Lloyd, Adam
    Trentino, Laura
    Jones, Glynis
    Murray, Kevin
    Thompson, Aleesha
    Halpin, Sarah
    Waterer, Grant
    DIGITAL HEALTH, 2024, 10
  • [22] Practical Considerations and Successful Implementation of Vital Signs Monitoring. Comment on "Continuous Versus Intermittent Vital Signs Monitoring Using a Wearable, Wireless Patch in Patients Admitted to Surgical Wards: Pilot Cluster Randomized Controlled Trial"
    Walsh, Caoimhe
    Zargaran, David
    Patel, Nikhil
    White, Amelia
    Koumpa, Foteini Stefania
    Tanna, Ravina
    Ashraf, Muhammad Arsalan
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2021, 23 (03)
  • [23] Performance of Continuous Glucose Monitoring in Patients With Observational Study
    Liu, Yanhua
    Zhang, Jianna
    Chun, Xueli
    Gao, Yongli
    Yao, Rong
    Liang, Yin
    Zhu, Ling
    He, Ying
    Huang, Wenxia
    ENDOCRINE PRACTICE, 2024, 30 (09) : 795 - 801
  • [24] An observational study of monitoring of vital signs in children admitted to Kenyan hospitals: an insight into the quality of nursing care?
    Ogero, Morris
    Ayieko, Philip
    Makone, Boniface
    Julius, Thomas
    Malla, Lucas
    Oliwa, Jacquie
    Irimu, Grace
    English, Mike
    JOURNAL OF GLOBAL HEALTH, 2018, 8 (01)
  • [25] Rapid response team patients triaged to remain on ward despite deranged vital signs: missed opportunities?
    Tirkkonen, J.
    Kontula, T.
    Hoppu, S.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2017, 61 (10) : 1278 - 1285
  • [26] Identifying quality markers of a safe surgical ward: An interview study of patients, clinical staff, and administrators
    Hassen, Yasmin
    Singh, Pritam
    Pucher, Philip H.
    Johnston, Maximilian J.
    Darzi, Ara
    SURGERY, 2018, 163 (06) : 1226 - 1233
  • [27] Continuous vital sign monitoring on surgical wards: The COSMOS pilot
    Anusic, Nikola
    Gulluoglu, Alper
    Ekrami, Elyad
    Mascha, Edward J.
    Li, Shuyi
    Coffeng, Rene
    Turan, Alparslan
    Clemens, Amber
    Perez, Christine
    Beard, John W.
    Sessler, Daniel I.
    JOURNAL OF CLINICAL ANESTHESIA, 2024, 99
  • [28] Patients' Perceptions of Quality of Care: A Teamwork Intervention Study in a Surgical Ward
    Hall-Lord, Marie Louise
    Ballangrud, Randi
    SAGE OPEN NURSING, 2022, 8
  • [29] Workload associated with manual assessment of vital signs as compared with continuous wireless monitoring
    Sigvardt, Emilie
    Gronbaek, Katja Kjaer
    Jepsen, Mia Lind
    Sogaard, Marlene
    Haahr, Louise
    Inacio, Ana
    Aasvang, Eske Kvanner
    Meyhoff, Christian Sylvest
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2024, 68 (02) : 274 - 279
  • [30] Reliability of a wearable wireless patch for continuous remote monitoring of vital signs in patients recovering from major surgery: a clinical validation study from the TRaCINg trial
    Downey, Candice
    Ng, Shu
    Jayne, David
    Wong, David
    BMJ OPEN, 2019, 9 (08):