MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms

被引:63
作者
Cejna, M
Loewe, C
Schoder, M
Dirisamer, A
Hölzenbein, T
Kretschmer, G
Lammer, J
Thurnher, S
机构
[1] Vienna Med Sch, Dept Radiol, A-1090 Vienna, Austria
[2] Vienna Med Sch, Dept Vasc Surg, A-1090 Vienna, Austria
关键词
aortic aneurysm; endovascular grafts; endoleak; MR angiography; CT angiography;
D O I
10.1007/s00330-002-1429-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Our objective was to evaluate the accuracy of contrast-enhanced 31) MR angiography (MRA) in the follow-up of patients with endoluminally treated aortic aneurysms and correlate these findings with uni- or biphasic CT angiography (CTA). Forty MR angiograms in 32 patients with implanted aortic nitinol stent grafts were compared to CTA. Twenty-two MR examinations were correlated with arterial-phase CTA (uniphasic), and 18 MR examinations were correlated with biphasic CTA. Uniphasic CTA demonstrated three type-1/type-3 endoleaks and four reperfusion (type-2) endoleaks. In addition, MRA depicted two type-2 reperfusion endoleaks that were missed by CTA. Using biphasic CTA, two type-1/type-3 endoleaks and three reperfusion (type-2) endoleaks were detected; of those, delayed scanning detected three reperfusion (type-2) endoleaks missed during arterial-phase CTA. In addition to the findings by CTA, MRA depicted another type-2 reperfusion endoleak. Magnetic resonance angiography is at least as sensitive as uni- or biphasic CTA for detecting endoleaks and may consequently offer advantages in patients with contraindications to iodinated contrast agents.
引用
收藏
页码:2443 / 2450
页数:8
相关论文
共 25 条
  • [1] Aortic aneurysmal disease: Assessment of stent-graft treatment - CT versus conventional angiography
    Armerding, MD
    Rubin, GD
    Beaulieu, CF
    Slonim, SM
    Olcott, EW
    Samuels, SL
    Jorgensen, MJ
    Semba, CP
    Jeffrey, RB
    Dake, MD
    [J]. RADIOLOGY, 2000, 215 (01) : 138 - 146
  • [2] Aneurysm sac pressure measurements after endovascular repair of abdominal aortic aneurysms
    Baum, RA
    Carpenter, RP
    Cope, C
    Golden, MA
    Velazquez, OC
    Neschis, DG
    Mitchell, ME
    Barker, CF
    Fairman, RM
    [J]. JOURNAL OF VASCULAR SURGERY, 2001, 33 (01) : 32 - 40
  • [3] Magnetic resonance imaging and MR angiography of endoluminally treated abdominal aortic aneurysms
    Engellau, L
    Larsson, EM
    Albrechtsson, U
    Jonung, T
    Ribbe, E
    Thorne, J
    Zdanowski, Z
    Norgren, L
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 1998, 15 (03) : 212 - 219
  • [4] Engellau L, 2000, J MAGN RESON IMAGING, V12, P112, DOI 10.1002/1522-2586(200007)12:1<112::AID-JMRI13>3.0.CO
  • [5] 2-G
  • [6] Improved uniformity of aortic enhancement with customized contrast medium injection protocols at CT angiography
    Fleischmann, D
    Rubin, GD
    Bankier, AA
    Hittmair, K
    [J]. RADIOLOGY, 2000, 214 (02) : 363 - 371
  • [7] Helical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition
    Golzarian, J
    Dussaussois, L
    Abada, HT
    Gevenois, PA
    Van Gansbeke, D
    Ferreira, J
    Struyven, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) : 329 - 331
  • [8] Imaging of abdominal aortic aneurysms after endoluminal repair
    Golzarian, J
    Dussaussois, L
    Struyven, J
    [J]. SEMINARS IN ULTRASOUND CT AND MRI, 1999, 20 (01) : 16 - 24
  • [9] Görich J, 1999, RADIOLOGY, V213, P767
  • [10] Harris PL, 1997, J ENDOVASC SURG, V4, P72, DOI 10.1583/1074-6218(1997)004<0072:TNFCTO>2.0.CO