Automatic retinal oximetry

被引:230
作者
Hardarson, Sveinn Hakon
Harris, Alon
Karlsson, Robert Arnar
Halldorsson, Gisli Hreinn
Kagemann, Larry
Rechtman, Ehud
Zoega, Gunnar Mar
Eysteinsson, Thor
Benediktsson, Jon Atli
Thorsteinsson, Adalbjorn
Jensen, Peter Koch
Beach, James
Stefansson, Einar [1 ]
机构
[1] Univ Iceland, Natl Univ Hosp, Dept Ophthalmol, IS-101 Reykjavik, Iceland
[2] Univ Iceland, Natl Univ Hosp, Dept Anesthesiol, IS-101 Reykjavik, Iceland
[3] Indiana Univ Purdue Univ, Dept Ophthalmol, Sch Med, Indianapolis, IN 46202 USA
[4] Univ Iceland, Fac Elect & Comp Engn, IS-101 Reykjavik, Iceland
[5] Univ Pittsburgh, Sch Med, Dept Ophthalmol, Pittsburgh, PA 15260 USA
[6] Natl Univ Hosp Copenhagen, Eye Dept, Copenhagen, Denmark
[7] Inst Technol Dev, Stennis Space Ctr, MS USA
关键词
D O I
10.1167/iovs.06-0039
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To measure hemoglobin oxygen saturation (SO2) in retinal vessels and to test the reproducibility and sensitivity of an automatic spectrophotometric oximeter. METHODS. Specialized software automatically identifies the retinal blood vessels on fundus images, which are obtained with four different wavelengths of light. The software calculates optical density ratios (ODRs) for each vessel. The reproducibility was evaluated by analyzing five repeated measurements of the same vessels. A linear relationship between SO2 and ODR was assumed and a linear model derived. After calibration, reproducibility and sensitivity were calculated in terms of SO2. Systemic hyperoxia (n = 16) was induced in healthy volunteers by changing the O-2 concentration in inhaled air from 21% to 100%. RESULTS. The automatic software enhanced reproducibility, and the mean SD for repeated measurements was 3.7% for arterioles and 5.3% venules, in terms of percentage of SO2 (five repeats, 10 individuals). The model derived for calibration was SO2 = 125 - 142 center dot ODR. The arterial SO2 measured 96% +/- 9% (mean +/- SD) during normoxia and 101% +/- 8% during hyperoxia (n = 16). The difference between normoxia and hyperoxia was significant (P = 0.0027, paired t-test). Corresponding numbers for venules were 55% +/- 14% and 78% +/- 15% (P < 0.0001). SO2 is displayed as a pseudocolor map drawn on fundus images. CONCLUSIONS. The retinal oximeter is reliable, easy to use, and sensitive to changes in SO2 when concentration of O-2 in inhaled air is changed.
引用
收藏
页码:5011 / 5016
页数:6
相关论文
共 69 条
  • [1] AHMED J, 1993, INVEST OPHTH VIS SCI, V34, P516
  • [2] ALDER VA, 1990, INVEST OPHTH VIS SCI, V31, P1029
  • [3] CHANGES IN VITREAL OXYGEN-TENSION DISTRIBUTION IN THE STREPTOZOTOCIN DIABETIC RAT
    ALDER, VA
    YU, DY
    CRINGLE, SJ
    SU, EN
    [J]. DIABETOLOGIA, 1991, 34 (07) : 469 - 476
  • [4] ARMALY MF, 1975, INVEST OPHTH VISUAL, V14, P724
  • [5] Augsten R, 1997, Eur J Ophthalmol, V7, P317
  • [6] Oximetry of retinal vessels by dual-wavelength imaging: calibration and influence of pigmentation
    Beach, JM
    Schwenzer, KJ
    Srinivas, S
    Kim, D
    Tiedeman, JS
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (02) : 748 - 758
  • [7] Drug intervention can correct subnormal retinal oxygenation response in experimental diabetic retinopathy
    Berkowitz, BA
    Roberts, R
    Luan, HM
    Peysakhov, J
    Knoerzer, DL
    Connor, JR
    Hohman, TC
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46 (08) : 2954 - 2960
  • [8] Regulation of the early subnormal retinal oxygenation response in experimental diabetes by inducible nitric oxide synthase
    Berkowitz, BA
    Luan, HM
    Gupta, RR
    Pacheco, D
    Seidner, A
    Roberts, R
    Liggett, J
    Knoerzer, DL
    Connor, JR
    Du, YP
    Kern, TS
    Ito, Y
    [J]. DIABETES, 2004, 53 (01) : 173 - 178
  • [9] Berkowitz BA, 2001, INVEST OPHTH VIS SCI, V42, P2964
  • [10] Berkowitz BA, 1999, INVEST OPHTH VIS SCI, V40, P2100