Binocular high dynamic range imaging system based on digital micromirror device

被引:2
作者
Sun, Honghai [1 ,2 ]
Wang, Yanjie [1 ,2 ]
Yang, Hang [1 ]
Wu, Pei [1 ]
机构
[1] Chinese Acad Sci, Changchun Inst Opt Fine Mech & Phys, Changchun 130033, Jilin, Peoples R China
[2] Chinese Acad Sci, Key Lab Airborne Opt Imaging & Measurement, Changchun 130033, Jilin, Peoples R China
基金
国家高技术研究发展计划(863计划);
关键词
High dynamic imaging; Image processing; Digital micromirror device; SENSOR; CAMERA;
D O I
10.1007/s11082-019-2014-6
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In the applications of scientific imaging and space exploration, the dynamic range of imaging systems is usually required to reach more than 120 dB. In order to observe a highly dynamic scene in real time, we designed an imaging system based on a digital micromirror device (DMD) that is used as a spatial light modulator. First, we designed a binocular highly dynamic light-adjusting system based on a DMD according to the DMD's optical structure. Second, in order to realize the registration between the micromirrors of a DMD and pixels of the two cameras, a pixel-matching algorithm was developed. Finally, we introduce a novel light-adjusting algorithm that can recover the highly dynamic data of the dynamic scene. Experiments showed that the deviation between the DMD and the two cameras is reduced to 0.48 pixels after correction, and that bright and dark targets in a high-dynamic-range scene can both be displayed simultaneously in one image with high quality after light adjustment. The dynamic range of the system is theoretically 209 dB, which meets the requirements of high-dynamic-range observation.
引用
收藏
页数:17
相关论文
共 50 条
  • [1] Binocular high dynamic range imaging system based on digital micromirror device
    Honghai Sun
    Yanjie Wang
    Hang Yang
    Pei Wu
    Optical and Quantum Electronics, 2019, 51
  • [2] Adaptive high-dynamic-range imaging method and its application based on digital micromirror device
    Feng Wei
    Zhang Fu-Min
    Wang Wei-Jing
    Qu Xing-Hua
    ACTA PHYSICA SINICA, 2017, 66 (23)
  • [3] A Distortion Self-Calibration Method for Binocular High Dynamic Light Adjusting and Imaging System Based on Digital Micromirror Device
    Wu, Pei
    Wang, Yanjie
    Sun, Honghai
    Wen, Zhuoman
    IEEE-CAA JOURNAL OF AUTOMATICA SINICA, 2024, 11 (09) : 2036 - 2038
  • [4] High dynamic range digital micromirror device-based infrared scene projector
    Mansur, David J.
    Vaillancourt, Robert
    Benedict-Gill, Ryan
    Newbry, Scott P.
    Dupuis, Julia Rentz
    JOURNAL OF MICRO-NANOLITHOGRAPHY MEMS AND MOEMS, 2014, 13 (01):
  • [5] Digital micromirror device camera with per-pixel coded exposure for high dynamic range imaging
    Feng, Wei
    Zhang, Fumin
    Wang, Weijing
    Xing, Wei
    Qu, Xinghua
    APPLIED OPTICS, 2017, 56 (13) : 3831 - 3840
  • [6] Study of an NIR Digital Micromirror Device-based Snapshot Spectral Imaging System
    Wu, Yuehao
    Mirza, Iftekhar O.
    Arce, Gonzalo. R.
    Prather, Dennis W.
    EMERGING DIGITAL MICROMIRROR DEVICE BASED SYSTEMS AND APPLICATIONS IV, 2012, 8254
  • [7] Research on Response Curve Calibration Method of Imaging System Based on Digital Micromirror Device
    Feng Wei
    Qu Xinghua
    Wang Weijing
    Zhang Fumin
    ACTA OPTICA SINICA, 2018, 38 (04)
  • [8] Source Simulation Experimental System Based on Digital Micromirror Device
    Chen Xueqi
    Jiang Aimin
    ACTA OPTICA SINICA, 2019, 39 (10)
  • [9] Dynamic IR scene projector based upon the digital micromirror device
    Beasley, DB
    Bender, M
    Crosby, J
    Messer, T
    Saylor, DA
    TECHNOLOGIES FOR SYNTHETIC ENVIRONMENTS: HARDWARE-IN-THE-LOOP TESTING VI, 2001, 4366 : 96 - 102
  • [10] Ghost imaging via compressive sampling based on digital micromirror device
    Lu M.
    Shen X.
    Han S.
    Guangxue Xuebao/Acta Optica Sinica, 2011, 31 (07):