Kinematic and kinetic comparisons of transfemoral amputee gait using C-Leg® and Mauch SNS® prosthetic knees

被引:190
作者
Segal, Ava D.
Orendurff, Michael S.
Mute, Glenn K.
McDowell, Martin L.
Pecoraro, Janice A.
Shofer, Jane
Czerniecki, Joseph M.
机构
[1] VA Puget Sound Hlth Care Syst, Ctr Excellence Limb Loss Prevent & Prosthet Engn, Dept Vet Affairs Rehabil Res & Dev, Seattle, WA 98108 USA
[2] Univ Washington, Dept Engn Mech, Seattle, WA 98195 USA
[3] Univ Washington, Dept Rehabil Med, Seattle, WA 98195 USA
[4] Univ Washington, Dept Elect Engn, Seattle, WA 98195 USA
关键词
amputee; biomechanics; C-Leg (R); gait; kinematics; kinetics; knee; microprocessor; rehabilitation; transfernoral;
D O I
10.1682/JRRD.2005.09.0147
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The C-Leg (R) (Otto Bock, Duderstadt, Germany) is a microprocessor-controlled prosthetic knee that may enhance amputee gait. This intrasubject randomized study compared the gait biomechanics of transfemoral amputees wearing the C-Lege with those wearing a common noncomputerized prosthesis, the Mauch SNS (R) (Ossur, Reykjavik, Iceland). After subjects had a 3-month acclimation period with each prosthetic knee, typical gait biomechanical data were collected in a gait laboratory. At a controlled walking speed (CWS), peak swing phase knee-flexion angle decreased for the C-Lege group compared with the Mauch SNS (R) group (55.2 degrees +/- 6.5 degrees vs 64.41 degrees +/- 5.8 degrees, respectively; p = 0.005); the C-Leg (R) group was similar to control subjects' peak swing knee-flexion angle (56.0 degrees +/- 3.4 degrees). Stance knee-flexion moment increased for the C-Legs group compared with the Mauch SNS (R) group (0.142 +/- 0.05 vs 0.067 +/- 0.07 N(.)m, respectively; p = 0.01), but remained significantly reduced compared with control subjects (0.477 +/- 0.1 N(.)m). Prosthetic limb step length at CWS was less for the C-Leg (R) group compared with the Mauch SNS (R) group (0.66 +/- 0.04 vs 0.70 +/- 0.06 in, respectively; p = 0.005), which resulted in increased symmetry between limbs for the C-Leg (R) group. Subjects also walked faster with the C-Leg (R) versus the Mauch SNS (R) (1.30 +/- 0.1 vs 1.21 +/- 0.1 m/s, respectively; p = 0.004). The C-Lee prosthetic limb vertical ground reaction force decreased compared with the Mauch SNS (R) (96.3 +/- 4.7 vs 100.3 +/- 7.5 % body weight, respectively; p = 0.0092).
引用
收藏
页码:857 / 869
页数:13
相关论文
共 30 条
[1]   DEVELOPMENT OF AN ABOVE-KNEE PROSTHESIS EQUIPPED WITH A MICROCOMPUTER-CONTROLLED KNEE-JOINT - 1ST TEST-RESULTS [J].
AEYELS, B ;
PEERAER, L ;
VANDERSLOTEN, J ;
VANDERPERRE, G .
JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (03) :199-202
[2]  
[Anonymous], BIOMECHANICS MOTOR C
[3]  
[Anonymous], 1999, MED ORTHOP TECHNOL
[4]  
CHRISTENSEN B, 1995, PROSTHET ORTHOT INT, V19, P46
[5]   Rehabilitation in limb deficiency .1. Gait and motion analysis [J].
Czerniecki, JM .
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1996, 77 (03) :S3-S8
[6]  
Datta D, 1998, PROSTHET ORTHOT INT, V22, P129
[7]  
ENGLISH RD, 1995, J REHABIL RES DEV, V32, P32
[8]  
Flynn K., 2000, COMPUTERIZED LOWER L
[9]  
GITTER A, 1995, AM J PHYS MED REHAB, V74, P332, DOI 10.1097/00002060-199509000-00002
[10]   FEASIBILITY OF AN ACTIVE CONTROL SCHEME FOR ABOVE KNEE PROSTHESES [J].
GRIMES, DL ;
FLOWERS, WC ;
DONATH, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1977, 99 (04) :215-221