Analysis of centration of Intacs segments implanted with a femtosecond laser

被引:16
作者
Ertan, Aylin [1 ]
Kamburoglu, Guenhal [1 ]
机构
[1] Kudret Eye Hosp, Ankara, Turkey
关键词
D O I
10.1016/j.jcrs.2006.11.007
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To analyze the centration of intrastromal ring segments (Intacs, Addition Technology, Inc.) implanted using a femtosecond laser in eyes with keratoconus. SETTING: Kudret Eye Hospital, Ankara, Turkey. METHODS: In a retrospective noncomparative case series, the distance of deviation of the intrastromal ring segment from the pupillary center was evaluated in 59 eyes of 39 keratoconic patients after tunnel creation with a femtosecond laser. The distance of deviation of segments from the pupillary edge and direction of decentration were analyzed using the anterior segment analyzer of the Pentacam Scheimpflug photographic camera (Oculus Opticgerate GmbH). RESULTS: Intacs were successfully implanted in all eyes. The mean horizontal deviation was 788.33 mu m +/- 500.34 (SD) (range 30 to 2450 gym), and there was a temporal displacement in all eyes. The mean vertical deviation was 370.83 +/- 343.17 mu m (range 0 to 1690 mu m), and there was an inferior displacement in 28.81% of eyes and superior displacement in 66.10% of eyes. There was no vertical displacement in 3 eyes (5.08%). CONCLUSION: During applanation for Intacs correction by a femtosecond laser, the cornea and pupil are not in their natural position, which leads to decentration and misalignment of the segments.
引用
收藏
页码:484 / 487
页数:4
相关论文
共 28 条
[1]   Positioning tolerances for phase plates compensating aberrations of the human eye [J].
Bará, S ;
Mancebo, T ;
Moreno-Barriuso, E .
APPLIED OPTICS, 2000, 39 (19) :3413-3420
[2]  
Barraquer J I, 1966, Int Ophthalmol Clin, V6, P53, DOI 10.1097/00004397-196606010-00004
[3]  
Buratto L, 1998, J REFRACT SURG, V14, P517
[4]  
Burris T E, 1991, Refract Corneal Surg, V7, P46
[5]   Effect of intrastromal corneal ring segment shift on clinical outcome: One year results for low myopia [J].
Cochener, B ;
Savary-LeFloch, G ;
Colin, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (07) :978-986
[6]   European clinical evaluation: Use of Intacs for the treatment of keratoconus [J].
Colin, J .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (05) :747-755
[7]   Correcting keratoconus with intracorneal rings [J].
Colin, J ;
Cochener, B ;
Savary, G ;
Malet, F .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2000, 26 (08) :1117-1122
[8]   INTACS inserts for treating keratoconus - One-year results [J].
Colin, J ;
Cochener, B ;
Savary, G ;
Malet, F ;
Holmes-Higgin, D .
OPHTHALMOLOGY, 2001, 108 (08) :1409-1414
[9]   Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations [J].
Guirao, A ;
Williams, DR ;
Cox, IG .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2001, 18 (05) :1003-1015
[10]  
Hellstedt T, 2005, J REFRACT SURG, V21, P236