High resolution 3D imaging of synchrotron generated microbeams

被引:15
|
作者
Gagliardi, Frank M. [1 ,2 ]
Cornelius, Iwan [3 ,4 ]
Blencowe, Anton [5 ,6 ]
Franich, Rick D. [7 ,8 ]
Geso, Moshi [2 ]
机构
[1] The Alfred, Alfred Hlth Radiat Oncol, Melbourne, Vic 3004, Australia
[2] RMIT Univ, Sch Med Sci, Bundoora, Vic 3083, Australia
[3] Australian Synchrotron, Imaging & Med Beamline, Clayton, Vic 3168, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2500, Australia
[5] Univ S Australia, Sch Pharm & Med Sci, Div Hlth Sci, Adelaide, SA 5000, Australia
[6] Univ S Australia, Mawson Inst, Div Informat Technol Engn & Environm, Mawson Lakes, SA 5095, Australia
[7] RMIT Univ, Sch Appl Sci, Melbourne, Vic 3000, Australia
[8] RMIT Univ, Hlth Innovat Res Inst, Melbourne, Vic 3000, Australia
关键词
MRT; microbeam imaging; PRESAGE (R) dosimeter; IntMRT; DynMRT; X-RAY MICROBEAMS; MONTE-CARLO-SIMULATION; RADIATION-THERAPY; MICROPLANAR BEAMS; MOSFET DOSIMETRY; TISSUE; BRAIN; RADIOSURGERY; RADIOTHERAPY; GLIOSARCOMA;
D O I
10.1118/1.4935410
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Microbeam radiation therapy (MRT) techniques are under investigation at synchrotrons worldwide. Favourable outcomes from animal and cell culture studies have proven the efficacy of MRT. The aim of MRT researchers currently is to progress to human clinical trials in the near future. The purpose of this study was to demonstrate the high resolution and 3D imaging of synchrotron generated microbeams in PRESAGE (R) dosimeters using laser fluorescence confocal microscopy. Methods: Water equivalent PRESAGE (R) dosimeters were fabricated and irradiated with microbeams on the Imaging and Medical Beamline at the Australian Synchrotron. Microbeam arrays comprised of microbeams 25-50 mu m wide with 200 or 400 mu m peak-to-peak spacing were delivered as single, cross-fire, multidirectional, and interspersed arrays. Imaging of the dosimeters was performed using a NIKON A 1 laser fluorescence confocal microscope. Results: The spatial fractionation of the MRT beams was clearly visible in 2D and up to 9 mm in depth. Individual microbeams were easily resolved with the full width at half maximum of microbeams measured on images with resolutions of as low as 0.09 mu m/pixel. Profiles obtained demonstrated the change of the peak-to-valley dose ratio for interspersed MRT microbeam arrays and subtle variations in the sample positioning by the sample stage goniometer were measured. Conclusions: Laser fluorescence confocal microscopy of MRT irradiated PRESAGE (R) dosimeters has been validated in this study as a high resolution imaging tool for the independent spatial and geometrical verification of MRT beam delivery. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:6973 / 6986
页数:14
相关论文
共 50 条
  • [1] MOSFET dosimetry with high spatial resolution in intense synchrotron-generated x-ray microbeams
    Siegbahn, E. A.
    Braeuer-Krisch, E.
    Bravin, A.
    Nettelbeck, H.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    MEDICAL PHYSICS, 2009, 36 (04) : 1128 - 1137
  • [2] Rat sensorimotor cortex tolerance to parallel transections induced by synchrotron-generated X-ray microbeams
    Fardone, Erminia
    Bravin, Alberto
    Conti, Alfredo
    Braeuer-Krisch, Elke
    Requardt, Herwig
    Bucci, Domenico
    Le Duc, Geraldine
    Battaglia, Giuseppe
    Romanelli, Pantaleo
    SCIENTIFIC REPORTS, 2017, 7
  • [3] Synchrotron-generated microbeams induce hippocampal transections in rats
    Fardone, Erminia
    Pouyatos, Benoit
    Brauer-Krisch, Elke
    Bartzsch, Stefan
    Mathieu, Herve
    Requardt, Herwig
    Bucci, Domenico
    Barbone, Giacomo
    Coan, Paola
    Battaglia, Giuseppe
    Le Duc, Geraldine
    Bravin, Alberto
    Romanelli, Pantaleo
    SCIENTIFIC REPORTS, 2018, 8
  • [4] High-angular resolution diffusion imaging generation using 3d u-net
    Suzuki, Yuichi
    Ueyama, Tsuyoshi
    Sakata, Kentarou
    Kasahara, Akihiro
    Iwanaga, Hideyuki
    Yasaka, Koichiro
    Abe, Osamu
    NEURORADIOLOGY, 2024, 66 (03) : 371 - 387
  • [5] High Resolution 3D Imaging of the Human Pancreas Neuro-insular Network
    Butterworth, Elizabeth
    Dickerson, Wesley
    Vijay, Vindhya
    Weitzel, Kristina
    Cooper, Julia
    Atkinson, Eric W.
    Coleman, Jason E.
    Otto, Kevin J.
    Campbell-Thompson, Martha
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2018, (131):
  • [6] High-resolution 3D imaging of whole organ after clearing: taking a new look at the zebrafish testis
    Fretaud, Maxence
    Riviere, Laurie
    De Job, Elodie
    Gay, Stephanie
    Lareyre, Jean-Jacques
    Joly, Jean-Stephane
    Affaticati, Pierre
    Thermes, Violette
    SCIENTIFIC REPORTS, 2017, 7
  • [7] Advances in studying whole mouse brain vasculature using high-resolution 3D light microscopy imaging
    Bennett, Hannah C.
    Kim, Yongsoo
    NEUROPHOTONICS, 2022, 9 (02)
  • [8] Aeration of the Human Prussak's Space: A 3D Synchrotron Imaging Study
    Li, Hao
    Giese, Dina
    Rohani, Seyed Alireza
    Zhu, Ning
    Ladak, Hanif M.
    Agrawal, Sumit
    Rask-Andersen, Helge
    OTOLOGY & NEUROTOLOGY, 2021, 42 (07) : E894 - E904
  • [9] Fluorescence Imaging of 3D Cell Models with Subcellular Resolution
    Van Zundert, Indra
    Maenhoudt, Nina
    De Vriendt, Silke
    Vankelecom, Hugo
    Fortuni, Beatrice
    Rocha, Susana
    BIO-PROTOCOL, 2022, 12 (14):
  • [10] 3D Cryo-Imaging: A Very High-Resolution View of the Whole Mouse
    Roy, Debashish
    Steyer, Grant J.
    Gargesha, Madhusudhana
    Stone, Meredith E.
    Wilson, David L.
    ANATOMICAL RECORD-ADVANCES IN INTEGRATIVE ANATOMY AND EVOLUTIONARY BIOLOGY, 2009, 292 (03): : 342 - 351