cholesterol biosensor; amperometry; polypyrrole (PPy); polyvinylsulphonate (PVS); entrapment; interference effect; SELF-ASSEMBLED MONOLAYERS; GLUCOSE-OXIDASE; AMPEROMETRIC DETERMINATION; CONDUCTING POLYMER; HYDROGEN-PEROXIDE; CARBON NANOTUBES; ELECTROCHEMICAL OXIDATION; PLATINUM NANOPARTICLES; CHARGE-TRANSFER; PRUSSIAN-BLUE;
D O I
10.3390/s90806435
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, a novel amperometric cholesterol biosensor with immobilization of cholesterol oxidase on electrochemically polymerized polypyrrole-polyvinylsulphonate (PPy-PVS) films has been accomplished via the entrapment technique on the surface of a platinum electrode. Electropolymerization of pyrrole and polyvinylsulphonate on the Pt surface was carried out by cyclic voltammetry between -1.0 and +2.0 V (vs. Ag/AgCl) at a scan rate of 100 mV upon the Pt electrode with an electrochemical cell containing pyrrole and polyvinylsulphonate. The amperometric determination is based on the electrochemical detection of H2O2 generated in the enzymatic reaction of cholesterol. Determination of cholesterol was carried out by the oxidation of enzymatically produced H2O2 at 0.4 V vs. Ag/AgCl. The effects of pH and temperature were investigated and optimum parameters were found to be 7.25 and 35 degrees C, respectively. The storage stability and operational stability of the enzyme electrode were also studied. The results show that 32% of the response current was retained after 19 activity assays. The prepared cholesterol biosensor retained 43% of initial activity after 45 days when stored in 0.1 M phosphate buffer solution at 4 degrees C.
引用
收藏
页码:6435 / 6445
页数:11
相关论文
共 41 条
[31]   An amperometric cholesterol biosensor based on multiwalled carbon nanotubes and organically modified sol-gel/chitosan hybrid composite film [J].
Tan, XC ;
Ll, MJ ;
Cai, PX ;
Luo, LJ ;
Zou, XY .
ANALYTICAL BIOCHEMISTRY, 2005, 337 (01) :111-120
[32]   Amperometric cholesterol biosensors based on carbon nanotube-chitosan-platinum-cholesterol oxidase nanobiocomposite [J].
Tsai, Yu-Chen ;
Chen, Siao-Yun ;
Lee, Chen-An .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 135 (01) :96-101
[33]   Strategies for the improvement of an amperometric cholesterol biosensor based on electropolymerization in flow systems: use of charge-transfer mediators and platinization of the electrode [J].
Vidal, JC ;
Garcia-Ruiz, E ;
Castillo, JR .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 24 (01) :51-63
[34]   Three approaches to the development of selective bilayer amperometric biosensors for glucose by in situ electropolymerization [J].
Vidal, JC ;
García, E ;
Méndez, S ;
Yarnoz, P ;
Castillo, JR .
ANALYST, 1999, 124 (03) :319-324
[35]   Amperometric cholesterol biosensors based on the electropolymerization of pyrrole and the electrocatalytic effect of Prussian-Blue layers helped with self-assembled monolayers [J].
Vidal, JC ;
Espuelas, J ;
Garcia-Ruiz, E ;
Castillo, JR .
TALANTA, 2004, 64 (03) :655-664
[36]   Comparison of biosensors based on entrapment of cholesterol oxidase and cholesterol esterase in electropolymerized films of polypyrrole and diaminonaphthalene derivatives for amperometric determination of cholesterol [J].
Vidal, JC ;
Garcia-Ruiz, E ;
Espuelas, J ;
Aramendia, T ;
Castillo, JR .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (02) :273-280
[37]   Bioelectrochemical characteristics of cholesterol oxidase immobilized in a polyaniline film [J].
Wang, HY ;
Mu, SL .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) :22-30
[38]   A new method for dispersing palladium microparticles in conducting polymer films and its application to biosensors [J].
Yamato, H ;
Koshiba, T ;
Ohwa, M ;
Wernet, W ;
Matsumura, M .
SYNTHETIC METALS, 1997, 87 (03) :231-236
[39]   Layer-by-layer self-assembled multilayer films of carbon nanotubes and platinum nanoparticles with polyelectrolyte for the fabrication of biosensors [J].
Yang, MH ;
Yang, Y ;
Yang, HF ;
Shen, GL ;
Yu, RQ .
BIOMATERIALS, 2006, 27 (02) :246-255
[40]   Immobilizing cholesterol oxidase in chitosan-alginic acid network [J].
Yapar, Elif ;
Kayahan, Senem Kiralp ;
Bozkurt, Ayhan ;
Toppare, Levent .
CARBOHYDRATE POLYMERS, 2009, 76 (03) :430-436