Effect of flow induced corrosion and erosion on failure of a tubular heat exchanger

被引:47
|
作者
Ranjbar, Khalil [1 ]
机构
[1] Shahid Chamran Univ, Fac Engn, Dept Mat, Ahvaz 61355, Iran
关键词
Dealloying - Heat exchangers - Chemical analysis - Binary alloys - Copper alloys - Cooling water - Steam power plants - Outages;
D O I
10.1016/j.matdes.2009.06.025
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Failure of a tubular heat exchanger made up of copper based alloys in a steam power plant was investigated. Tubes were made initially from yellow brass, and there after replaced by Cu-5Ni alloys. Circulating water from cooling tower was used as coolant, to condense the hot steam inside the steel shell. The velocity of cooling water was found to be very low, causing accumulation of deposits, reduction of diameter and some times complete blockage of tubes. The causes of failure were investigated performing various tests such as chemical analysis, XRD, optical, and SEM examination. Study revealed that tube material suffering from extensive dealloying and impingement attack. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:613 / 619
页数:7
相关论文
共 50 条
  • [1] Erosion-corrosion failure of a spiral heat exchanger
    Pimenta, G.
    MATERIALS PERFORMANCE, 2007, 46 (12) : 50 - 52
  • [2] Corrosion Failure Analysis of Flow Plate in Plate Heat Exchanger
    Song, Min Ji
    Choi, Gahyun
    Chae, Hobyung
    Kim, Woo Cheol
    Kim, Heesan
    Kim, Jung-Gu
    Lee, Soo Yeol
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2021, 20 (04): : 204 - 209
  • [3] Erosion-corrosion of heat exchanger tubes
    Kuznicka, B.
    ENGINEERING FAILURE ANALYSIS, 2009, 16 (07) : 2382 - 2387
  • [4] Corrosion failure analysis for heat exchanger
    Jing, Hongyang
    Shang, Jin
    Xu, Lianyong
    Han, Yongdian
    Hanjie Xuebao/Transactions of the China Welding Institution, 2016, 37 (09): : 1 - 4
  • [5] Corrosion Failure Analysis on Heat Exchanger Pipes
    Qiankun Z.
    Yafei S.
    Sixian R.
    Huifeng L.
    Xingjiang Z.
    Journal of Failure Analysis and Prevention, 2017, 17 (2) : 349 - 353
  • [6] Corrosion Failure of Aluminum Heat Exchanger Tubes
    Ifezue D.
    Tobins F.H.
    Journal of Failure Analysis and Prevention, 2015, 15 (4) : 541 - 547
  • [7] Experimental investigation on the effect of corrosion and erosion on the shell and tube-type heat exchanger
    Siva, R.
    Mageshwaran, G.
    Kallat, Sanjana
    Jeevahan, Jeya
    INTERNATIONAL JOURNAL OF AMBIENT ENERGY, 2021, 42 (07) : 816 - 822
  • [8] EROSION-CORROSION IN HEAT-EXCHANGER TUBE INLETS
    MEYER, U
    ATRENS, A
    MATERIALS PERFORMANCE, 1994, 33 (04) : 57 - 60
  • [9] Dynamics of a tubular heat exchanger with arbitrary flow perturbation
    Lorenzini, E
    Giuliani, E
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2002, 42 (08) : 833 - 854
  • [10] Experimental investigation of the flow distribution inside a tubular heat exchanger
    Faure, Thierry M.
    Lusseyran, Francois
    Gougat, Pierre
    Launay, Francois
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2006, 128 (06): : 1218 - 1227