CT Guidance is Needed to Achieve Reproducible Positioning of the Mouse Head for Repeat Precision Cranial Irradiation

被引:28
作者
Armour, M. [1 ]
Ford, E. [1 ]
Iordachita, I. [2 ]
Wong, J. [1 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Radiat Oncol & Mol Radiat Sci, Baltimore, MD 21231 USA
[2] Johns Hopkins Univ, Whiting Sch Engn, Lab Computat Sensing & Robot, Baltimore, MD 21231 USA
关键词
RADIATION RESEARCH PLATFORM; CONE-BEAM-CT; HIPPOCAMPAL NEUROGENESIS; HIGH-RESOLUTION; SYSTEM; BRAIN; RADIOTHERAPY; MICRORT; CELLS; RAT;
D O I
10.1667/RR1845.1
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
To study the effects of cranial irradiation, we have constructed an all-plastic mouse bed equipped with an immobilizing head holder. The bed integrates with our in-house Small Animal Radiation Research Platform (SARRP) for precision focal irradiation experiments and cone-beam CT. We assessed the reproducibility of our head holder to determine the need for CT-based targeting in cranial irradiation studies. To measure the holder's reproducibility, a C57BL/6 mouse was positioned and CT-scanned nine times. Image sets were loaded into the Pinnacle'(3) radiation treatment planning system and were registered to one another by one investigator using rigid body alignment of the cranial regions. Rotational and translational offsets were measured. The average vector shift between scans was 0.80 +/- 0.49 mm. Such a shift is too large to selectively treat subregions of the mouse brain. In response, we use onboard imaging to guide cranial irradiation applications that require sub-millimeter precision. (C) 2010 by Radiation Research Society
引用
收藏
页码:119 / 123
页数:5
相关论文
共 19 条
  • [1] AUTORADIOGRAPHIC AND HISTOLOGICAL EVIDENCE OF POSTNATAL HIPPOCAMPAL NEUROGENESIS IN RATS
    ALTMAN, J
    DAS, GD
    [J]. JOURNAL OF COMPARATIVE NEUROLOGY, 1965, 124 (03) : 319 - &
  • [2] Radiation response of neural precursor cells
    Fike, John R.
    Rola, Radoslaw
    Limoli, Charles L.
    [J]. NEUROSURGERY CLINICS OF NORTH AMERICA, 2007, 18 (01) : 115 - +
  • [3] Franklin K. B. J., 2013, MOUSE BRAIN STEREOTA
  • [4] Consistent and reproducible slice selection in rodent brain using a novel stereotaxic device for MRI
    Fricke, ST
    Vink, R
    Chiodo, C
    Cernak, I
    Ileva, L
    Faden, AI
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2004, 136 (01) : 99 - 102
  • [5] Irradiation-induced progenitor cell death in the developing brain is resistant to erythropoietin treatment and caspase inhibition
    Fukuda, H
    Fukuda, A
    Zhu, C
    Korhonen, L
    Swanpalmer, J
    Hertzman, S
    Leist, M
    Lannering, B
    Lindholm, D
    Björk-Eriksson, T
    Marky, I
    Blomgren, K
    [J]. CELL DEATH AND DIFFERENTIATION, 2004, 11 (11) : 1166 - 1178
  • [6] Design and evaluation of a variable aperture collimator for conformal radiotherapy of small animals using a microCT scanner
    Graves, Edward E.
    Zhou, Hu
    Chatterjee, Raja
    Keall, Paul J.
    Gambhir, Sanjiv Sam
    Contag, Christopher H.
    Boyer, Arthur L.
    [J]. MEDICAL PHYSICS, 2007, 34 (11) : 4359 - 4367
  • [7] A SYSTEM FOR STEREOTAXIC IRRADIATION AND MAGNETIC-RESONANCE EVALUATIONS IN THE RAT-BRAIN
    KARGER, CP
    HARTMANN, GH
    HOFFMANN, U
    LORENZ, WJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (02): : 485 - 492
  • [8] Feasibility of small animal cranial irradiation with the microRT system
    Kiehl, Erich L.
    Stojadinovic, Strahinja
    Malinowski, Kathleen T.
    Limbrick, David
    Jost, Sarah C.
    Garbow, Joel R.
    Rubin, Joshua B.
    Deasy, Joseph O.
    Khullar, Divya
    Izaguirre, Enrique W.
    Parikh, Parag J.
    Low, Daniel A.
    Hope, Andrew J.
    [J]. MEDICAL PHYSICS, 2008, 35 (10) : 4735 - 4743
  • [9] Cone-beam-CT guided radiation therapy:: technical implementation
    Létourneau, D
    Wong, JW
    Oldham, M
    Gulam, M
    Watt, L
    Jaffray, DA
    Siewerdsen, JH
    Martinez, AA
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 279 - 286
  • [10] LINDSAY P, 2008, J MED PHYS, V35, P2695