We report the case of a 36-year-old woman admitted for cryptogenic stroke, in whom the Patent Foramen Ovalle (PFO) diameter measurement, with a purpose built sizing balloon, performed before the closure procedure, was complicated with the rupture of the inter-atrial septum generating an Atria[ Septal Defect (ASD) with a significant left-to-right shunt. This kind of complication may not be easy to handle, changing the initial procedural strategy from PFO to ASD closure technique requiring specific material and operator's technical skill. (c) 2006 Wiley-Liss, Inc.
引用
收藏
页码:274 / 276
页数:3
相关论文
共 7 条
[1]   Incidence and clinical course of thrombus formation on atrial septal defect and patient foramen ovale closure devices in 1,000 consecutive patients [J].
Krumsdorf, U ;
Ostermayer, S ;
Billinger, K ;
Trepels, T ;
Zadan, E ;
Horvath, K ;
Sievert, H .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (02) :302-309
[2]   Interatrial septal abnormalities and stroke - A meta-analysis of case-control studies [J].
Overell, JR ;
Bone, I ;
Lees, KR .
NEUROLOGY, 2000, 55 (08) :1172-1179
[3]   Migraine headache relief after transcatheter closure of patent foramen ovale [J].
Reisman, M ;
Christofferson, RD ;
Jesurum, J ;
Olsen, JV ;
Spencer, MP ;
Krabill, KA ;
Diehl, L ;
Aurora, S ;
Gray, WA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (04) :493-495
[4]   Transesophageal echocardiography for quantifying size of patent foramen ovale in patients with cryptogenic cerebrovascular events [J].
Schuchlenz, HW ;
Weihs, W ;
Beitzke, A ;
Stein, JI ;
Gamillscheg, A ;
Rehak, P .
STROKE, 2002, 33 (01) :293-296
[5]   Percutaneous closure of patent foramen ovale: impact of device design on safety and efficacy [J].
Schwerzmann, M ;
Windecker, S ;
Wahl, A ;
Mehta, H ;
Nedeltchev, K ;
Mattle, H ;
Seiler, C ;
Meier, B .
HEART, 2004, 90 (02) :186-190
[6]   Prognosis after percutaneous closure of patent foramen ovale for paradoxical embolism [J].
Wahl, A ;
Meier, B ;
Haxel, B ;
Nedeltchev, K ;
Arnold, M ;
Eicher, E ;
Sturzenegger, M ;
Seiler, C ;
Mattle, HP ;
Windecker, S .
NEUROLOGY, 2001, 57 (07) :1330-1332
[7]   Comparison of medical treatment with percutaneous closure of patent foramen ovale in patients with cryptogenic stroke [J].
Windecker, S ;
Wahl, A ;
Nedeltchev, K ;
Arnold, M ;
Schwerzmann, M ;
Seiler, C ;
Mattle, HP ;
Meier, B .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 44 (04) :750-758