Considerations on the role of the magnetic field gradient in ECR ion sources and build-up of hot electron component

被引:49
作者
Gammino, S. [1 ]
Mascali, D. [1 ,2 ]
Celona, L. [1 ]
Maimone, F. [1 ]
Ciavola, G. [1 ]
机构
[1] Ist Nazl Fis Nucl, Lab Nazl Sud, I-95123 Catania, Italy
[2] Univ Catania, Dipartimento Fis & Astron, I-95123 Catania, Italy
关键词
MICROWAVE FREQUENCY; MIRROR; WAVES;
D O I
10.1088/0963-0252/18/4/045016
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The measurements of x-ray bremsstrahlung spectra from electron cyclotron resonance (ECR) ion sources have shown in the past that the electrons may gain energy inside the plasma up to about 2 MeV. In 2000 a series of experiments carried out at INFN-LNS with the SERSE source operating at 28 GHz provided evidence that high energy x-rays were produced, as the heat load on the cryostat was increased because of their dissipation on the cold mass. This result shows that the knowledge of ECR heating is incomplete, because the so-called adiabatic limit was exceeded by many electrons. More recently similar measurements were carried out at IMP, Lanzhou, with the SECRAL source, and with the VENUS (Versatile ECR for Nuclear Science) source at LBNL, operating at 28 GHz with a better plasma confinement than SERSE. It will be shown hereinafter that the generation of energetic electrons (up to 2 MeV) is mainly related to the magnetic field gradient; also the charge state distribution depends on the magnetic structure, and its variation can be studied in terms of regime transition from gentle to strong gradients. For this purpose, numerical simulations of the ECR heating based on a single particle approach have been used.
引用
收藏
页数:10
相关论文
共 27 条
[11]   Numerical simulations of the ECR heating with waves of different frequency in electron cyclotron resonance ion sources [J].
Gammino, Santo ;
Ciavola, Giovanni ;
Celona, Luigi G. ;
Mascali, David ;
Maimone, Fabio .
IEEE TRANSACTIONS ON PLASMA SCIENCE, 2008, 36 (04) :1552-1568
[12]   MINIMAFIOS, PULSED ION-SOURCE WHICH CAN FURNISH IONS AT A LOW REPETITION RATE AND IN THE CW REGIME [J].
GELLER, R ;
JACQUOT, B .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 202 (03) :399-401
[13]  
Geller R., 1987, P 8 INT WORKSH ECR I, V1, P22
[14]  
GELLER R, 1996, ELECT CYCLOTRON RESO
[15]  
Golovanivsky K. S., 1994, Plasma Sources, Science and Technology, V3, P233, DOI 10.1088/0963-0252/3/2/014
[16]   ECRIS plasmas: stochastic heating or Langmuir caviton collapses? [J].
Golovanivsky, Konstantin S. .
PLASMA SOURCES SCIENCE & TECHNOLOGY, 1993, 2 (04) :240-249
[17]   PROPOSED PHYSICAL MODEL FOR VERY HOT-ELECTRON SHELL STRUCTURES IN ELECTRON-CYCLOTRON RESONANCE-DRIVEN PLASMAS [J].
GOLOVANIVSKY, KS ;
DOUGARJABON, VD ;
REZNIKOV, DV .
PHYSICAL REVIEW E, 1995, 52 (03) :2969-2973
[18]   Influence of broadened pump wave spectra on the stochastic heating in an ECR mirror machine [J].
Ivanov, AA ;
Wolters, U ;
Meyer, D ;
Buzzi, JM ;
Wiesemann, K .
EUROPHYSICS LETTERS, 2002, 59 (06) :841-847
[19]  
JEAGER F, 1973, PLASMA PHYS, V15, P125
[20]  
JEAGER F, 1972, PLASMA PHYS, V14, P1073