摘要
A promising electrochemical biosensor was developed by electrodeposition of palladium nanoclusters on polyfuran film modified platinum electrode. This biosensor electrode was used to determine some catecholamines, namely dopamine, epinephrine and norepinephrine, ascorbic acid and paracetamol. The method of formation of the polymer film and deposition of I'd particles plays a key role in the electroactivity of the resulting hybrid material. This sensor effectively resolved the overlapping anodic peaks of ascorbic acid (AA), dopamine (DA) and paracetamol (ACOP) into three well-defined voltammetric peaks in differential pulse voltammetry analysis. The detection limit of DA in the absence and presence of AA and ACOP are eventually the same which indicates that the oxidation processes of DA, AA and ACOP are independent and that the simultaneous measurements of the three analytes are possible without interference. The electrodeposition of Pd on polyfuran improved exceptionally the detection limit about four decades. Moreover, diffusion coefficient measurements confirmed the fast electron transfer kinetics of the electrochemical oxidation of the analyte molecules at the sensor/solution interface. It is very interesting to note that the electrocatalytic effect of PF/Pd composite has been increased to be sometimes 21 times that of the pristine PF which has been considered for a long time to be of low conductivity and attracted low attention as a result of the difficulty of its formation and poor conductivity. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:566 / 574
页数:9
相关论文
共 71 条
[1]   Polymers in sensor applications [J].
Adhikari, B ;
Majumdar, S .
PROGRESS IN POLYMER SCIENCE, 2004, 29 (07) :699-766
[2]  
[Anonymous], 2004, Int J Polym Mater, DOI DOI 10.1080/00914030490472908
[3]   Poly(3-methylthiophene)/palladium sub-micro-modified sensor electrode. Part II: Voltammetric and EIS studies, and analysis of catecholamine neurotransmitters, ascorbic acid and acetaminophen [J].
Atta, Nada F. ;
El-Kady, Maher F. .
TALANTA, 2009, 79 (03) :639-647
[4]   Conducting composites of polythiophene and polyfuran with acetylene black [J].
Ballav, N ;
Biswas, M .
POLYMER INTERNATIONAL, 2005, 54 (04) :725-729
[5]   Preparation and evaluation of nanocomposites of polyfuran with Al2O3 and montmorillonite clay [J].
Ballav, N ;
Biswas, M .
POLYMER INTERNATIONAL, 2004, 53 (10) :1467-1472
[6]  
Bard A.J., 2001, ELECTROCHEMICAL METH
[7]   Determination of 5-hydroxytryptamine (serotonin) and related indoles by flow injection analysis with acidic potassium permanganate chemiluminescence detection [J].
Barnett, NW ;
Hindson, BJ ;
Lewis, SW .
ANALYTICA CHIMICA ACTA, 1998, 362 (2-3) :131-139
[8]   A sensor for acetaminophen in a blood medium using a Cu(II)-conducting polymer complex modified electrode [J].
Boopathi, M ;
Won, MS ;
Shim, YB .
ANALYTICA CHIMICA ACTA, 2004, 512 (02) :191-197
[9]   Direct injection analysis of epinephrine, norepinephrine, and their naturally occurring derivatives in serum by micellar liquid chromatography with electrochemical detection [J].
Bose, D ;
Durgbanshi, A ;
Carda-Broch, S ;
Gil-Agustí, M ;
Capella-Peiró, ME ;
Esteve-Romero, J .
JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2005, 28 (20) :3265-3281
[10]   CYCLIC AND DIFFERENTIAL PULSE VOLTAMMETRIC BEHAVIOR OF REACTANTS CONFINED TO ELECTRODE SURFACE [J].
BROWN, AP ;
ANSON, FC .
ANALYTICAL CHEMISTRY, 1977, 49 (11) :1589-1595