Acute effects of vibration on peripheral blood flow in healthy subjects

被引:40
作者
Egan, CE [1 ]
Espie, BH [1 ]
McGrann, SM [1 ]
McKenna, KM [1 ]
Allen, JA [1 ]
机构
[1] QUEENS UNIV BELFAST,SCH BIOMED SCI PHYSIOL,CTR MED BIOL,BELFAST BT9 7BL,ANTRIM,NORTH IRELAND
关键词
vibration; hand vibration; finger blood flow;
D O I
10.1136/oem.53.10.663
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Objectives-The main objective was to study the acute vascular effects in the hands of normal healthy subjects of a complex vibration spectrum similar to that generated by many industrial hand held tools. The effects of repeated bouts of vibrations and alterations in the intensity of vibration were also studied. Methods-Blood flow was measured by venous occlusion plethysmography with strain gauges. Vibration across a frequency range of 0.4 to > 4000 Hz was generated by a pneumatic chisel and applied to the right hand. Blood flow was measured in both middle fingers, both big toes, or both forearms before, during, and after a two minute period of vibration. Systolic pressure of a finger and heart rate were also measured. Results-Vibration was associated with a significant bilateral reduction in finger and toe blood flow (P < 0.01 and P < 0.03) and a significant increase in heart rate (P < 0.05) but had no effect on forearm blood flow. The finger response was not abolished by repeated bouts of the vibration but was initially most notable during the first minute of vibration. Increasing the intensity of vibration delayed recovery. Conclusions-Hand vibration causes a generalised increase in sympathetic tone in the heart and extremities. This may be a factor in the development of vasospastic disease in habitual users of hand held industrial vibrating tools.
引用
收藏
页码:663 / 669
页数:7
相关论文
共 10 条
  • [1] FARKKILA M, 1979, SCAND J WORK ENV HEA, V5, P368
  • [2] Greenstein D, 1992, Proc Inst Mech Eng H, V206, P105, DOI 10.1243/PIME_PROC_1992_206_274_02
  • [3] BLOOD-PRESSURE MEASUREMENT OF ALL 5 FINGERS BY STRAIN-GAUGE PLETHYSMOGRAPHY
    HIRAI, M
    NIELSEN, SL
    LASSEN, NA
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1976, 36 (07) : 627 - 632
  • [4] HYVARINEN J, 1973, LANCET, V1, P791
  • [5] VASCULAR-RESPONSES IN CHAIN SAW OPERATORS
    MCKENNA, KM
    BLANN, AD
    ALLEN, JA
    [J]. OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 1994, 51 (06) : 366 - 370
  • [6] MITCHELL RH, 1987, P IEEE MONT C BIOM T, P167
  • [7] OLSEN N, 1988, BRIT J IND MED, V45, P415
  • [8] Pyykko I, 1982, VIBRATION EFFECTS HA, P13
  • [9] Roddie IC, 1983, HDB PHYSL CARDIOVASC, P285
  • [10] THE EFFECT OF VIBRATION ON DIGITAL BLOOD-FLOW
    WELSH, CL
    [J]. BRITISH JOURNAL OF SURGERY, 1980, 67 (10) : 708 - 710